犬实验性骨折外固定治疗及 X 线追踪观察
1
作者 李维 《养犬》 1998年第4期18-20,共3页
犬只外科疾病,尤其是外科骨折性疾病常有发生。为了观察犬只骨折治疗预后情况,在华南农业大学动物医院做了四例犬只实验性骨折外固定治疗效果与 X 线检查追踪观察,现报告如下。
关键词 实验性骨折 骨折外固定治疗 X射线观察
原文传递
小切口单侧外固定架治疗胫腓骨闭合42例
2
作者 胡鹤利 《中国民族民间医药》 2011年第15期100-101,共2页
单侧外固定架不仅在开放性胫腓骨折,尤其是软组织损伤较重的开放性骨折的治疗中疗效肯定,而且在闭合性胫腓骨骨折中也有很高的应用价值。我院自1999年4月至2006年6月问采用小切口单侧外固定架治疗胫腓骨闭合骨折42例,疗效满意,先总... 单侧外固定架不仅在开放性胫腓骨折,尤其是软组织损伤较重的开放性骨折的治疗中疗效肯定,而且在闭合性胫腓骨骨折中也有很高的应用价值。我院自1999年4月至2006年6月问采用小切口单侧外固定架治疗胫腓骨闭合骨折42例,疗效满意,先总结如下。 展开更多
关键词 小切口单侧固定治疗骨折
下载PDF
Biomechanical analysis of fracture fixation with external fixator in vivo
3
作者 MING Jiang-hua ZHOU Pang-hu ZHOU Jian-peng 《Chinese Journal of Traumatology》 CAS 2006年第2期100-104,共5页
Objective :To investigate the different ways of measuring the main axial strain during treatment with an external fixator and to find the suitable compression loaded by the external fixator at an early stage. Method... Objective :To investigate the different ways of measuring the main axial strain during treatment with an external fixator and to find the suitable compression loaded by the external fixator at an early stage. Methods. Eighteen healthy big-ear rabbits were randomly divided into two groups according to different measuring methods: Group A and Group B. In Group A, a strain gauge was affixed to the external tibiai cortex with 502 glue, and in Group B, a bone cement-coated strain gauge was installed on the internal tibial cortex. Groups A and B were divided into two subgroups A1, A2 and B1, B2, respectively, according to the pressure of haft of and the same as the body weight. A Z-shaped left mid-shaft tibiai osteotomy was performed and fixed by an external fixator. Results: The scaler curves of Group A changed dramatically during the early stage. The trendlines of the internal and external cortex went consistently after reaching the stable stage while the latter strain value was higher than the former. The time for Group B reaching the stable stage was short, but its absolute strain value was less than that of Group A. Before they were pressed to the stable stage, the declined speed of Subgroup A1 was more slowly than that of Subgroup A2 while the results of Subgroups B1 and B2 were same. Group A had an ascending trend after it declined while Group B didn't have. After they reached the stable stage, both Subgroups A1 and A2 had a declining trend while Subgroup A2 was more quickly than Subgroup A1, Subgroup B1 was kept at a definite level while Subgroup B2 fluctuated. Conclusions: The axial strain under external fixator can be measured by bone cement coated-strain gauge in vivo. The data may suggest that half of the body weight load was suitable for external fixator. 展开更多
关键词 Fracture fixation BIOMECHANICS External fixators