Objective: To explore the mechanical behavior of lumbar spine loaded by stress and provide the mechanical basis for clinical analysis and judgement of lumbar spine fracture classification, mechanical distribution and...Objective: To explore the mechanical behavior of lumbar spine loaded by stress and provide the mechanical basis for clinical analysis and judgement of lumbar spine fracture classification, mechanical distribution and static stress. Methods: By means of computer simulation method, the constructed lumbar spine three-dimensional model was introduced into three-dimensional finite element analysis by software Ansys 7.0. The lumbar spine mechanical behavior in different parts of the stress loading were calculated. Impact load is 0-8000 N. The peak value was 8000 N. The loading time is 0-40 minutes. The values of the main stress, stress distribution and the lumbar spine unit displacement in the direction of main stress were analyzed. Results: The lumbar spine model was divided into a total of 121 239 nodes, 112 491 units. It could objectively reflect the true anatomy of lumbar spine and its biomechanical behavior and obtain the end-plate images under different stress. The stress distribution on the lumbar intervertebral disc (L3-L4) under the axial, lateral flexion and extension stress, and the displacement trace of the corresponding processus articularis were analyzed. Conclusion: It is helpful to analyze the stress distribution of lumbar spine and units displacement in static stress loading in the clinical research of lumbar spine injury and the distribution of internal stress.展开更多
Porous Ti-lOMo alloys were fabricated by powder metallurgy using a space-holder method. The pore characteristics, m icrostructure, mechanical properties, in vitro biocompatibility, and in vivo osseointegration of the ...Porous Ti-lOMo alloys were fabricated by powder metallurgy using a space-holder method. The pore characteristics, m icrostructure, mechanical properties, in vitro biocompatibility, and in vivo osseointegration of the fabricated alloys were systematically investigated. The results show that with different weight ratios of the space-holder (NH4- HC03) added, all of the porous Ti-10Mo alloys sintered at 1,300℃ exhibited a typical W idmanstatten microstructure. The porosity and average pore size of the porous structures can be controlled in the range of 50.8%-66.9% and 70.1 -381.4μm , respectively. The Ti-10Mo alloy with 63.4% porosity exhibited the most suitable mechanical properties for implant applications with an elastic modulus of 2.9 GPa and a compressive yield strength of 127.5 MPa. In vitro9 the alloyconditioned medium showed no deleterious effect on the cell proliferation. The cell viability in this medium was higher than that of the reference group, suggesting non-toxicity and good biological characteristics of the alloy specimens. In vivo, after eight weeks* implantation, new bone tissue formed surrounding the alloy implants, and no noticeable inflammation was observed at the implantation site. The bone bonding strength of the porous Ti-10Mo alloy increased over time from 46.6N at two weeks to 176.4 N at eight weeks. Suitable mechanical properties together with excellent biocompatibility in vitro and osteointegration in vivo make the porous Ti-10Mo fabricated by powder metallurgy an attractive orthopedic implant alloy.展开更多
文摘Objective: To explore the mechanical behavior of lumbar spine loaded by stress and provide the mechanical basis for clinical analysis and judgement of lumbar spine fracture classification, mechanical distribution and static stress. Methods: By means of computer simulation method, the constructed lumbar spine three-dimensional model was introduced into three-dimensional finite element analysis by software Ansys 7.0. The lumbar spine mechanical behavior in different parts of the stress loading were calculated. Impact load is 0-8000 N. The peak value was 8000 N. The loading time is 0-40 minutes. The values of the main stress, stress distribution and the lumbar spine unit displacement in the direction of main stress were analyzed. Results: The lumbar spine model was divided into a total of 121 239 nodes, 112 491 units. It could objectively reflect the true anatomy of lumbar spine and its biomechanical behavior and obtain the end-plate images under different stress. The stress distribution on the lumbar intervertebral disc (L3-L4) under the axial, lateral flexion and extension stress, and the displacement trace of the corresponding processus articularis were analyzed. Conclusion: It is helpful to analyze the stress distribution of lumbar spine and units displacement in static stress loading in the clinical research of lumbar spine injury and the distribution of internal stress.
基金supported by the Fundamental Research Funds for the Central Universities (FRF-GF-17-B39)the financial support for this research by the National Health and Medical Research Council (NHMRC), Australia through project grant (GNT1087290)
文摘Porous Ti-lOMo alloys were fabricated by powder metallurgy using a space-holder method. The pore characteristics, m icrostructure, mechanical properties, in vitro biocompatibility, and in vivo osseointegration of the fabricated alloys were systematically investigated. The results show that with different weight ratios of the space-holder (NH4- HC03) added, all of the porous Ti-10Mo alloys sintered at 1,300℃ exhibited a typical W idmanstatten microstructure. The porosity and average pore size of the porous structures can be controlled in the range of 50.8%-66.9% and 70.1 -381.4μm , respectively. The Ti-10Mo alloy with 63.4% porosity exhibited the most suitable mechanical properties for implant applications with an elastic modulus of 2.9 GPa and a compressive yield strength of 127.5 MPa. In vitro9 the alloyconditioned medium showed no deleterious effect on the cell proliferation. The cell viability in this medium was higher than that of the reference group, suggesting non-toxicity and good biological characteristics of the alloy specimens. In vivo, after eight weeks* implantation, new bone tissue formed surrounding the alloy implants, and no noticeable inflammation was observed at the implantation site. The bone bonding strength of the porous Ti-10Mo alloy increased over time from 46.6N at two weeks to 176.4 N at eight weeks. Suitable mechanical properties together with excellent biocompatibility in vitro and osteointegration in vivo make the porous Ti-10Mo fabricated by powder metallurgy an attractive orthopedic implant alloy.