期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
一种高速可靠的VDMOS高位开关电路
1
作者 吴传国 《石油化工高等学校学报》 CAS 1997年第2期45-47,共3页
VDMOS场效应功率晶体管具有双极型和一般MOS器件的优点。但这种器件作为高速高位开关电路应用时 ,由于驱动电压发生电路的设计中存在某些因素会影响整个开关电路的性能和整个电路的体积、重量和价格。针对这些影响因素 ,设计了一个VDMO... VDMOS场效应功率晶体管具有双极型和一般MOS器件的优点。但这种器件作为高速高位开关电路应用时 ,由于驱动电压发生电路的设计中存在某些因素会影响整个开关电路的性能和整个电路的体积、重量和价格。针对这些影响因素 ,设计了一个VDMOS高速高位开位电路。该电路具有开关速度高 ,体积小 ,重量轻、价格廉等优点。该电路经过实际应用 。 展开更多
关键词 场效应 双扩散 高位开关 VDMOS 功率晶体管
下载PDF
An Improved Active Miller Clamp Crosstalk Suppression Method for Enhancement-Mode GaN HEMTs in Phase-Leg Configuration
2
作者 QIN Haihong WANG Wenlu +3 位作者 BU Feifei PENG Zihe LIU Ao BAI Song 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2021年第5期758-768,共11页
When using traditional drive circuits,the enhancement-mode GaN(eGaN)HEMT will be affected by high switching speed characteristics and parasitic parameters leading to worse crosstalk problems.Currently,the existing cro... When using traditional drive circuits,the enhancement-mode GaN(eGaN)HEMT will be affected by high switching speed characteristics and parasitic parameters leading to worse crosstalk problems.Currently,the existing crosstalk suppression drive circuits often have the disadvantages of increased switching loss,control complexity,and overall electromagnetic interference(EMI).Therefore,this paper combines the driving loop impedance control and the active Miller clamp method to propose an improved active Miller clamp drive circuit.First,the crosstalk mechanism is analyzed,and the crosstalk voltage model is established.Through the crosstalk voltage evaluation platform,the influencing factors are evaluated experimentally.Then,the operating principle of the improved active Miller clamp drive circuit is discussed,and the optimized parameter design method is given.Finally,the effect of the improved active Miller clamp method for suppressing crosstalk is experimentally verified.The crosstalk voltage was suppressed from 3.5 V and-3.5 V to 1 V and-1.3 V,respectively,by the improved circuit. 展开更多
关键词 enhancement-mode GaN(eGaN) crosstalk suppression gate driver high-speed switching active clamp
下载PDF
Influence of Isotope Substitution Helium Atom on Partial Cross Sections in He-HF Collisions
3
作者 YU Chun-Ri ZHANG Jie CHEN Li JIANG Gui-Sheng HUANG Guo-Dong 《Communications in Theoretical Physics》 SCIE CAS CSCD 2009年第11期924-928,共5页
Close-coupling equation and anisotropic potential developed in our previous research are applied to HE-SHe (4He, 6He, 8He,10He) collision system, and partial cross sections (PCSs) at the incident energy of 40 me V... Close-coupling equation and anisotropic potential developed in our previous research are applied to HE-SHe (4He, 6He, 8He,10He) collision system, and partial cross sections (PCSs) at the incident energy of 40 me V are calculated. By analyzing the differences of these PCSs, change rules of PCSs with the increase of partial wave number, and with the change of the mass of isotope substitution helium atom are obtained. The results show that excitation PCSs converge faster than elastic PCSs for collision energy and each of systems considered here. Also excitation PCSs converge more rapidly for high-excited states. Tail effect is present only in elastic scattering and low-excited states but not in high- excited states. With the increase of the mass of isotope substitution helium atom, converging speed of elastic, total inelastic, and state-to-state excitation PCS slows down, and the maxima of these PCSs undergoes a regular change. 展开更多
关键词 isotope substitution partial cross section close-coupling equation He-HF collision
下载PDF
A long-term follow-up study of high tibial osteotomy for medial compartment osteoarthrosis 被引量:4
4
作者 吴立东 Hans J Hahne Toachim Hassenpflug 《Chinese Journal of Traumatology》 CAS 2004年第6期348-353,共6页
Objective: To observe the long-term outcome of high tibial osteotomy (HTO) in treating medial compartment osteoarthrosis of knees. Methods: A retrospective study was carried out on 194 patients (215 knees) treated wit... Objective: To observe the long-term outcome of high tibial osteotomy (HTO) in treating medial compartment osteoarthrosis of knees. Methods: A retrospective study was carried out on 194 patients (215 knees) treated with HTO for medial compartment osteoarthritis at the Orthopaedic Hospital of Kiel University between 1985 and 1996. Results: One hundred and sixty-one knees (144 patients) were followed up for (1.5)-12 years with an average of (7.5) years and their data were reviewed. The proportion of excellent outcome were (97.3)%, (93.6)% and (78.2)% two, five and over five years after HTO, respectively. The revision rate of total knee arthroplasty (TKA) was (11.8)% (19 knees retreated with TKA for HTO failure). The survivorship analysis of the 19 knees retreated with TKA showed an expected survival rate of (98.7%), (95.0%) and (84.1)% 2, 5 and 10 years after HTO, respectively. There were (5.6)% complications (12 /161), including five superficial wound infections, one deep infection, five delayed bone healing, and one peroneal nerve palsy. Fifty patients (54 knees) missed follow-up, among them 10 patients (11 knees) died.Conclusions: HTO is an effective method in treating medial compartment osteoarthritis with a varus knee. Appropriate overcorrection of femorotibial alignment is the key for the success of the operation. But as the long-term effect is concerned, there is a trend of deterioration and some of the patients may have a second operation of revision with TKA. 展开更多
关键词 High tibial Osteotomy KNEE OSTEOARTHRITIS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部