The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas...The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.展开更多
In this paper,a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it.The ionized electric field around the building is...In this paper,a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it.The ionized electric field around the building is reduced due to the shielding effect of the building and the shielding distance is about three times its height.The ionized electric field including the human body model on the building and away from the building is also taken into account.The ionized electric field distortion ratio of the human body model is discussed in this paper.The distortion ratios for the positions on the building are less than those on the ground.展开更多
文摘The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.
基金supported by the Key Project of the National Natural Science Foundation of China(Grant No.51037001)the National Basic Research Program of China("973"Program)(Grant No.2011CB209401)
文摘In this paper,a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it.The ionized electric field around the building is reduced due to the shielding effect of the building and the shielding distance is about three times its height.The ionized electric field including the human body model on the building and away from the building is also taken into account.The ionized electric field distortion ratio of the human body model is discussed in this paper.The distortion ratios for the positions on the building are less than those on the ground.