高压输电线路微机保护装置的研究与开发 被引量:1
1
作者 潘贞存 赵建国 +3 位作者 高广玲 郑涛 邹运和 孟令军 《山东工业大学学报》 2002年第1期34-38,共5页
研制开发了一套适合于 110kV高压输电线路的成套微机保护装置 .它采用多CPU并行工作结构 ,具有CAN -BUS通讯接口 ,能够实现距离保护、零序保护、检同期重合闸等保护功能和正常监视测量、远方通讯和人机交互等监控功能 .既可以与变电站... 研制开发了一套适合于 110kV高压输电线路的成套微机保护装置 .它采用多CPU并行工作结构 ,具有CAN -BUS通讯接口 ,能够实现距离保护、零序保护、检同期重合闸等保护功能和正常监视测量、远方通讯和人机交互等监控功能 .既可以与变电站综合自动化系统配合 ,作为前置单元使用 ,也可以独立于综合自动化系统单独使用 .经静模实验和动模实验测试 ,该装置原理正确、性能优良 ,各项技术指标都达到了设计的要求 . 展开更多
关键词 高压输电路线 微机保护装置 线路保护装置 距离保护 零序保护
下载PDF
Nonlinear dynamical response of high-voltage transmission lines based on cable dropping 被引量:1
2
作者 夏开全 刘云 钱振东 《Journal of Southeast University(English Edition)》 EI CAS 2009年第1期52-56,共5页
In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilib... In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilibrium condition of the coupling system model is verified by nonlinear static analysis. The transient dynamic analysis method is proposed to analyze the variation law of dynamic response under cable or insulator rupture, and the dynamic response of structural elements next to the broken span is calculated. The results show that upper crossarm cable rupture has no effect on cable tension at adjacent suspension points, but it has a significant influence on tension in the insulator and the tower component of the upper crossarm next to the broken span. The peak tension in the conductor of the upper crossarm at the suspension point exceeds the design value under insulator rupture. Insulator rupture has no effect on the tower component of the upper crossarm, but it has a significant influence on insulator tension of the upper crossarm. Insulator rupture should be taken into account in the design of overhead transmission lines. The research results can provide a theoretical basis for the design of transmission lines. 展开更多
关键词 high-voltage transmission line transient response cable dropping numerical simulation finite element method
下载PDF
NEW PRINCIPLE FOR DIRECTIONAL COMPARISON CARRIER PROTECTION OF EHV TRANSMISSION LINES 被引量:1
3
作者 王钢 李遥 +2 位作者 余晓丹 刘众仆 贺家李 《Transactions of Tianjin University》 EI CAS 1998年第2期6-10,共5页
The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave ch... The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave channels is the most suitable protection scheme for long distance EHV transmission lines and is widely used in power systems.The key element of such protection is a directional relay used to discriminate the fault direction.In order to overcome the disadvantages of conventional directional relays,the authors of this paper put forward the directional comparison carrier protection based on the artificial neural network(ANN).The protection is extensively tested using electromagnetic transient program (EMTP) under various electric power system operating and fault conditions.It is proved that the directional comparison carrier protection based on ANN,which can recognize various fault patterns of the protected transmission line(such as fault direction,fault phases etc.)correctly in any kind of operating and fault conditions and the whole process,is satisfactory for EHV transmission line protection. 展开更多
关键词 artificial neural network EHV transmission line directional comparison carrier protection
下载PDF
Modeling of electrode system for three-phase electric arc furnace 被引量:5
4
作者 王琰 毛志忠 +2 位作者 田惠欣 李妍 袁平 《Journal of Central South University》 SCIE EI CAS 2010年第3期560-565,共6页
To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the pra... To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the practical situation. They are the power supply system model the electric arc model and the hydraulic actuator system model. According to the basic circuit theory, the power supply system model where the high voltage transmission circuit and mutual inductances were considered, was set up. The electric arc model, which was novel for the electrode control, served as the electrical load and was connected to the power supply system model. The hydraulic actuator system model consists of the proportional valve part that is modeled to capture the dead-zone nonlinear characteristics and the hydraulic cylinder part where the impact of the load force is taken into account. By comparing simulation data and actual data, the results show that the electrode system model is proved to be accurate. 展开更多
关键词 electric arc furnace electrode system model electric arc model SIMULATION
下载PDF
Geospatial Solutions in Practice for Smart Grids
5
作者 Peter Birk Chris Pavlovski 《Computer Technology and Application》 2011年第3期165-171,共7页
Recently, smart grid solutions have started to extend the visibility of the electrical grid to the entire network; including high voltage transmission lines, medium voltage distribution networks, and the low voltage n... Recently, smart grid solutions have started to extend the visibility of the electrical grid to the entire network; including high voltage transmission lines, medium voltage distribution networks, and the low voltage networks to households. The typical data monitored includes: voltage, current, phase, and power measurements, together with network events and alarms. This paper analyses the key challenges facing smart grid solutions in providing effective access to large volumes of sensory data that is distributed over a large geographic area. A case study is described that outlines how the use of geospatial technology together with Web 2.0 technologies may be applied to improve user access and control to this data. The results show that a geospatial solution provides an effective mechanism for visualizing telemetry data monitored within the smart grid. 展开更多
关键词 GEOSPATIAL energy distribution graphical information system (GIS) smart grid.
下载PDF
Novel Algorithm for Estimating the Distance of Open-Conductor Faults in HV Transmission Lines
6
作者 Mahmoud Gilany Ahmed Al-Kandari Bahaa Hassan 《Journal of Energy and Power Engineering》 2012年第8期1301-1307,共7页
This paper presents an ANN (artificial neural networks)-based technique for improving the performance of distance relays against open-circuit faults in transmission networks. The technique utilizes the small capacit... This paper presents an ANN (artificial neural networks)-based technique for improving the performance of distance relays against open-circuit faults in transmission networks. The technique utilizes the small capacitive current measured in the open-phase plus the currents in the two healthy phases in calculating the open-circuit fault distance. The results obtained show that a distance relay with the proposed scheme will not only be able to detect the open-conductor condition in HVTL (high voltage transmission line) but also to locate the place of this fault regardless the value of the pre-fault current loading. There is no need for especial communication schemes since the existing media could work properly for the needs of the proposed technique. 展开更多
关键词 Distance relay open-conductor ANN transmission networks fault location.
下载PDF
A Novel Technology for Generation of Electricity and Cold by Using Energy Potential of Transmission Line's High Pressure Gas 被引量:1
7
作者 Zohrab Melikyan 《Journal of Energy and Power Engineering》 2015年第10期852-859,共8页
The main objective of this paper is to develop a novel technology for combined generation of electricity and cold by using energy potential of transmission line's high pressure gas. For this purpose, the reduction of... The main objective of this paper is to develop a novel technology for combined generation of electricity and cold by using energy potential of transmission line's high pressure gas. For this purpose, the reduction of high pressure of the gas in gas distribution station instead of useless expansion throttling process is suggested to realize by adiabatic expansion, which is executed in a gas expanding turbine. Herewith, the gas distribution station is turned into energy and cold generating plant. Simultaneous operation of energy and cold generating plant is described. A method and appropriate formulas for determination of design characteristics of considered plant are suggested. A new method for reveres order of calculation and design of the cold store based on the use of expanded cold gas as cooling agent is developed. Calculations and analysis prove high energy efficiency of suggested technology, the wide use of which will provide significant production of cheap electricity and cold and as well as reduction of fossil fuel consumption. 展开更多
关键词 Natural gas gas distribution station throttling valve turbo-expander isenthalpic adiabatic.
下载PDF
Modeling of an ionized electric field on the building near the UHVDC transmission line 被引量:8
8
作者 ZHEN YongZan CUI Xiang LU TieBing 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第4期747-753,共7页
In this paper,a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it.The ionized electric field around the building is... In this paper,a 3D upstream finite element method is developed to analyze the ionized electric field around the UHVDC transmission lines including the building near it.The ionized electric field around the building is reduced due to the shielding effect of the building and the shielding distance is about three times its height.The ionized electric field including the human body model on the building and away from the building is also taken into account.The ionized electric field distortion ratio of the human body model is discussed in this paper.The distortion ratios for the positions on the building are less than those on the ground. 展开更多
关键词 BUILDING finite element method (fem) human body HVDC ionized electric field
原文传递
Fault component integrated impedance-based pilot protection scheme for EHV/UHV transmission line with thyristor controlled series capacitor(TCSC) and controllable shunt reactor(CSR) 被引量:1
9
作者 HE ShiEn SUONAN JaLe +1 位作者 KANG XiaoNing JIAO ZaiBin 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第2期342-350,共9页
This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integr... This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integrated impedance (FCII) calculated for a transmission line with TCSC and controllable shunt reactor (CSR). The FCII is defined as the ratio of the sum of the fault component voltage phasors of a transmission line with TCSC and CSR to the sum of the fault component current phasors where all the phasors are determined at both line's terminals. It can be used to distinguish internal faults occurring on the line from external ones. If the fault is an external one the FCII reflects the line's capacitive impedance and has large value. If the fault is an internal one on the line the FCII reflects the impedance of the equivalent system and the line and is relatively small. The new pilot protection scheme can be easily set and has the fault phase selection ability and also it is not affected by the capacitive current and the fault transition resistance. It is not sensitive to compensation level and dynamics of TCSC and CSR. The effectiveness of the new scheme is validated against data obtained in ATP simulations and Northwest China 750 kV Project. 展开更多
关键词 EHV/UHV transmission line pilot protection fault component integrated impedance (FCII) thyristor controlled seriescapacitor (TCSC) controllable shunt reactor (CSR)