The usability of test results of ship model vertical center of gravity and transverse moment of inertia is generally depends on its uncertainty. Referring to the guidelines for uncertainty analysis in examination of l...The usability of test results of ship model vertical center of gravity and transverse moment of inertia is generally depends on its uncertainty. Referring to the guidelines for uncertainty analysis in examination of liquid dynamic recommended by International Towing Tank Conference ( ITTC), the results were analyzed, bias limits and precision limits were calculated and total uncertainty was estimated. The total uncertainty of six tests on ship model vertical center of gravity is is 0. 16% of the mean value, and the total uncertainty of six tests on ship model transverse moment of inertia is 5.66% of the mean value. The test results show that the total uncertainty of both the multiple tests and the single test is from the precision limits of ship model vertical center of gravity and transverse moment of inertia tests. Thus, the improved measurement system stability can enormously decrease the total uncertainty of multiple tests and the single test.展开更多
The spatial orientation of optical radiation sources has long been the hot topic in the aerospace and the military applications.Current researches mainly focus on the high precision orientation on the partial field of...The spatial orientation of optical radiation sources has long been the hot topic in the aerospace and the military applications.Current researches mainly focus on the high precision orientation on the partial field of view.Thus,combination of several partial fields of view is required to achieve orientation when the field of view exceeds 180°,which results in the increase of size,weight,power consumption and the cost.By defining radiation energy and direction of the optical radiation source as a vector and applying the cosine law of radiation and vector theorem,it is shown that the vector can be obtained from unit normal vectors on the three un-coplanar surfaces and from the energy projected by the optical radiation source.Based on this,an orientation method with 360° full field of view by a polyhedron is suggested,the mathematical formula for anti-multipath interference is supposed and the error upper limit is derived.The feasibility and effectiveness of this method are validated by measurements and simulation.An accuracy better than 2.866° and 0.574° is achieved when the ratio of measurement error of energy on arbitrary surface and the true value are 5% and 1%,respectively,given the matrix composed of unit normal vectors on three measurement surfaces is orthogonal.展开更多
基金supported by the Natural Science Foundation of Hunan Province (Grant No. 2021JJ30790)the National Natural Science Foundation of China (Grant No. 51972345)+2 种基金the Hunan Provincial Science and Technology Plan Project (Grant Nos. 2018RS3008 and 2017TP1001)the Open Sharing Fund for the Large-scale Instruments and Equipments of Central South UniversityPostgraduate Scientific Research Innovation Project of Hunan Province (Grant No. 2021zzts0524)。
文摘The usability of test results of ship model vertical center of gravity and transverse moment of inertia is generally depends on its uncertainty. Referring to the guidelines for uncertainty analysis in examination of liquid dynamic recommended by International Towing Tank Conference ( ITTC), the results were analyzed, bias limits and precision limits were calculated and total uncertainty was estimated. The total uncertainty of six tests on ship model vertical center of gravity is is 0. 16% of the mean value, and the total uncertainty of six tests on ship model transverse moment of inertia is 5.66% of the mean value. The test results show that the total uncertainty of both the multiple tests and the single test is from the precision limits of ship model vertical center of gravity and transverse moment of inertia tests. Thus, the improved measurement system stability can enormously decrease the total uncertainty of multiple tests and the single test.
文摘The spatial orientation of optical radiation sources has long been the hot topic in the aerospace and the military applications.Current researches mainly focus on the high precision orientation on the partial field of view.Thus,combination of several partial fields of view is required to achieve orientation when the field of view exceeds 180°,which results in the increase of size,weight,power consumption and the cost.By defining radiation energy and direction of the optical radiation source as a vector and applying the cosine law of radiation and vector theorem,it is shown that the vector can be obtained from unit normal vectors on the three un-coplanar surfaces and from the energy projected by the optical radiation source.Based on this,an orientation method with 360° full field of view by a polyhedron is suggested,the mathematical formula for anti-multipath interference is supposed and the error upper limit is derived.The feasibility and effectiveness of this method are validated by measurements and simulation.An accuracy better than 2.866° and 0.574° is achieved when the ratio of measurement error of energy on arbitrary surface and the true value are 5% and 1%,respectively,given the matrix composed of unit normal vectors on three measurement surfaces is orthogonal.