A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing. The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K, and produce a ...A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing. The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K, and produce a no-load temperature of 57.0 K, operating with an average pressure of 2.50 MPa and a frequency of 60 Hz, performance results that are very close to the calculated values. The cryocooler can be cooled from room temperature to 80 K in 8.5 min. The fast cooldown time is a result of the small regenerator.展开更多
The fracture behaviour and morphologies of high-strength boron steel were investigated at different temperatures at a constant strain rate of 0.1 s-1 based on isothermal tensile tests. Fracture mechanisms were also an...The fracture behaviour and morphologies of high-strength boron steel were investigated at different temperatures at a constant strain rate of 0.1 s-1 based on isothermal tensile tests. Fracture mechanisms were also analyzed based on the relationship between microstructure transformation and continuous cooling transformation(CCT) curves. It is found that 1) fractures of the investigated steel at high temperatures are dimple fractures; 2) the deformation of high-strength boron steel at high temperatures accelerates diffusion transformations; thus, to obtain full martensite, a higher cooling rate is needed; and 3) the investigated steel has the best plasticity when the deformation temperature is 750 °C.展开更多
基金the National Natural Science Foundation of China (No. 50676081)the Science and Technology Department of Zhejiang Province (No. 2007C30063), China
文摘A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing. The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K, and produce a no-load temperature of 57.0 K, operating with an average pressure of 2.50 MPa and a frequency of 60 Hz, performance results that are very close to the calculated values. The cryocooler can be cooled from room temperature to 80 K in 8.5 min. The fast cooldown time is a result of the small regenerator.
基金Project(51305317)supported by the National Natural Science Foundation of ChinaProjects(WUT:2013-IV-092,WUT:2014-VII-002)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(IRT13087)supported by Innovative Research Team Development Program of Ministry of Education of China
文摘The fracture behaviour and morphologies of high-strength boron steel were investigated at different temperatures at a constant strain rate of 0.1 s-1 based on isothermal tensile tests. Fracture mechanisms were also analyzed based on the relationship between microstructure transformation and continuous cooling transformation(CCT) curves. It is found that 1) fractures of the investigated steel at high temperatures are dimple fractures; 2) the deformation of high-strength boron steel at high temperatures accelerates diffusion transformations; thus, to obtain full martensite, a higher cooling rate is needed; and 3) the investigated steel has the best plasticity when the deformation temperature is 750 °C.