期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
紫外摄像机在白天探测输电线的电晕放电 被引量:2
1
作者 顾聚兴 《红外》 CAS 2002年第1期44-44,共1页
空中检查为大面积监视输电线的隐患(例如绝缘子的碎裂,可能会造成停电)提供了一条有效的途径.用紫外摄像机可探测作为高压输电线和高压设备漏电征兆的电晕放电现象.然而,据电力研究所的有关专家说,迄今为止,这种摄像机只能在夜间工作,... 空中检查为大面积监视输电线的隐患(例如绝缘子的碎裂,可能会造成停电)提供了一条有效的途径.用紫外摄像机可探测作为高压输电线和高压设备漏电征兆的电晕放电现象.然而,据电力研究所的有关专家说,迄今为止,这种摄像机只能在夜间工作,在夜间,紫外B区域和紫外A区域的太阳辐射不会把这两个波段中微弱的电晕放电效应掩盖起来. 展开更多
关键词 漏电检测 高电压输电线 压设备 紫外摄像机 电晕放电
下载PDF
Modeling of electrode system for three-phase electric arc furnace 被引量:5
2
作者 王琰 毛志忠 +2 位作者 田惠欣 李妍 袁平 《Journal of Central South University》 SCIE EI CAS 2010年第3期560-565,共6页
To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the pra... To simulate the process of electrode operation, a dynamic model describing the electrode system of three-phase electric arc furnace was developed. This new model can be divided into three submodels in terms of the practical situation. They are the power supply system model the electric arc model and the hydraulic actuator system model. According to the basic circuit theory, the power supply system model where the high voltage transmission circuit and mutual inductances were considered, was set up. The electric arc model, which was novel for the electrode control, served as the electrical load and was connected to the power supply system model. The hydraulic actuator system model consists of the proportional valve part that is modeled to capture the dead-zone nonlinear characteristics and the hydraulic cylinder part where the impact of the load force is taken into account. By comparing simulation data and actual data, the results show that the electrode system model is proved to be accurate. 展开更多
关键词 electric arc furnace electrode system model electric arc model SIMULATION
下载PDF
Modern Travelling Wave Based Fault Location Techniques for HVDC Transmission Lines 被引量:6
3
作者 陈平 徐丙垠 +1 位作者 李京 葛耀中 《Transactions of Tianjin University》 EI CAS 2008年第2期139-143,共5页
The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas... The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation. 展开更多
关键词 fault location global positioning system HVDC transmission lines REPEATERS
下载PDF
Overvoltage Suppression for UHV Transmission Lines
4
作者 李永丽 刘太华 +3 位作者 李仲青 景雷 龙英 范建忠 《Transactions of Tianjin University》 EI CAS 2008年第3期222-225,共4页
The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV)... The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level. 展开更多
关键词 OVERVOLTAGE RECLOSING relay protection shunt reactors SUPPRESSION UHV transmission lines
下载PDF
A Novel Technology for Generation of Electricity and Cold by Using Energy Potential of Transmission Line's High Pressure Gas 被引量:1
5
作者 Zohrab Melikyan 《Journal of Energy and Power Engineering》 2015年第10期852-859,共8页
The main objective of this paper is to develop a novel technology for combined generation of electricity and cold by using energy potential of transmission line's high pressure gas. For this purpose, the reduction of... The main objective of this paper is to develop a novel technology for combined generation of electricity and cold by using energy potential of transmission line's high pressure gas. For this purpose, the reduction of high pressure of the gas in gas distribution station instead of useless expansion throttling process is suggested to realize by adiabatic expansion, which is executed in a gas expanding turbine. Herewith, the gas distribution station is turned into energy and cold generating plant. Simultaneous operation of energy and cold generating plant is described. A method and appropriate formulas for determination of design characteristics of considered plant are suggested. A new method for reveres order of calculation and design of the cold store based on the use of expanded cold gas as cooling agent is developed. Calculations and analysis prove high energy efficiency of suggested technology, the wide use of which will provide significant production of cheap electricity and cold and as well as reduction of fossil fuel consumption. 展开更多
关键词 Natural gas gas distribution station throttling valve turbo-expander isenthalpic adiabatic.
下载PDF
Novel Algorithm for Estimating the Distance of Open-Conductor Faults in HV Transmission Lines
6
作者 Mahmoud Gilany Ahmed Al-Kandari Bahaa Hassan 《Journal of Energy and Power Engineering》 2012年第8期1301-1307,共7页
This paper presents an ANN (artificial neural networks)-based technique for improving the performance of distance relays against open-circuit faults in transmission networks. The technique utilizes the small capacit... This paper presents an ANN (artificial neural networks)-based technique for improving the performance of distance relays against open-circuit faults in transmission networks. The technique utilizes the small capacitive current measured in the open-phase plus the currents in the two healthy phases in calculating the open-circuit fault distance. The results obtained show that a distance relay with the proposed scheme will not only be able to detect the open-conductor condition in HVTL (high voltage transmission line) but also to locate the place of this fault regardless the value of the pre-fault current loading. There is no need for especial communication schemes since the existing media could work properly for the needs of the proposed technique. 展开更多
关键词 Distance relay open-conductor ANN transmission networks fault location.
下载PDF
Geospatial Solutions in Practice for Smart Grids
7
作者 Peter Birk Chris Pavlovski 《Computer Technology and Application》 2011年第3期165-171,共7页
Recently, smart grid solutions have started to extend the visibility of the electrical grid to the entire network; including high voltage transmission lines, medium voltage distribution networks, and the low voltage n... Recently, smart grid solutions have started to extend the visibility of the electrical grid to the entire network; including high voltage transmission lines, medium voltage distribution networks, and the low voltage networks to households. The typical data monitored includes: voltage, current, phase, and power measurements, together with network events and alarms. This paper analyses the key challenges facing smart grid solutions in providing effective access to large volumes of sensory data that is distributed over a large geographic area. A case study is described that outlines how the use of geospatial technology together with Web 2.0 technologies may be applied to improve user access and control to this data. The results show that a geospatial solution provides an effective mechanism for visualizing telemetry data monitored within the smart grid. 展开更多
关键词 GEOSPATIAL energy distribution graphical information system (GIS) smart grid.
下载PDF
Fault component integrated impedance-based pilot protection scheme for EHV/UHV transmission line with thyristor controlled series capacitor(TCSC) and controllable shunt reactor(CSR) 被引量:1
8
作者 HE ShiEn SUONAN JaLe +1 位作者 KANG XiaoNing JIAO ZaiBin 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第2期342-350,共9页
This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integr... This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integrated impedance (FCII) calculated for a transmission line with TCSC and controllable shunt reactor (CSR). The FCII is defined as the ratio of the sum of the fault component voltage phasors of a transmission line with TCSC and CSR to the sum of the fault component current phasors where all the phasors are determined at both line's terminals. It can be used to distinguish internal faults occurring on the line from external ones. If the fault is an external one the FCII reflects the line's capacitive impedance and has large value. If the fault is an internal one on the line the FCII reflects the impedance of the equivalent system and the line and is relatively small. The new pilot protection scheme can be easily set and has the fault phase selection ability and also it is not affected by the capacitive current and the fault transition resistance. It is not sensitive to compensation level and dynamics of TCSC and CSR. The effectiveness of the new scheme is validated against data obtained in ATP simulations and Northwest China 750 kV Project. 展开更多
关键词 EHV/UHV transmission line pilot protection fault component integrated impedance (FCII) thyristor controlled seriescapacitor (TCSC) controllable shunt reactor (CSR)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部