[Objective] This paper aimed to study the treatment process of high con- centration wastewater from organic fungicide production by using Fenton oxidation. [Method] The alkali out pretreatment was used to investigate ...[Objective] This paper aimed to study the treatment process of high con- centration wastewater from organic fungicide production by using Fenton oxidation. [Method] The alkali out pretreatment was used to investigate the effects of NaOH concentration, molar ratio of H2O2 to Fe2+ and H202 dosage on COD removal rate and decolourization ratio. [Result] The optimal operating conditions were determined as follows: pH=3.0, NaOH concentration of 15 g/L, n [H2O2]:n [Fe2+] =4.20, reaction time of 30 min. [Conclmio.] The research provided scientific references for the treatment of high concentration wastewater from fungicide production.展开更多
基金Supported by the Overall Strategic Cooperation Program of Chinese Academy of Sciences in Guangdong Province(2012B09040046)~~
文摘[Objective] This paper aimed to study the treatment process of high con- centration wastewater from organic fungicide production by using Fenton oxidation. [Method] The alkali out pretreatment was used to investigate the effects of NaOH concentration, molar ratio of H2O2 to Fe2+ and H202 dosage on COD removal rate and decolourization ratio. [Result] The optimal operating conditions were determined as follows: pH=3.0, NaOH concentration of 15 g/L, n [H2O2]:n [Fe2+] =4.20, reaction time of 30 min. [Conclmio.] The research provided scientific references for the treatment of high concentration wastewater from fungicide production.