Static corrections using the conventional method are basically conducted in two steps, the weathering correction followed by the correction from the top of the sub-weathering to the unified datum. However, the convent...Static corrections using the conventional method are basically conducted in two steps, the weathering correction followed by the correction from the top of the sub-weathering to the unified datum. However, the conventional method fails to well deal with statics problems in case the top of the sub-weathering is sharply undulated and the lateral velocity of the sub-weathering varies significantly. This brings us to the introduction of a smooth intermediate reference datum (IRD) located under the top of the sub-weathering, which helps to further increase the accuracy of statics based on the weathering corrections, and ensures the imaging quality. Good results based on the IRD technique have been achieved in the complex areas in western China. This paper discusses the IRD functions, its application requirements, and selection of related parameters. Some typical sections for comparison are also given in this paper.展开更多
Background: To understand an effective golf swing, both swing speed and impact precision must be thoroughly and simultaneously examined. The aim of this study was to perform both swing speed test and impact precision...Background: To understand an effective golf swing, both swing speed and impact precision must be thoroughly and simultaneously examined. The aim of this study was to perform both swing speed test and impact precision test to ascertain what swing type determines an effective impact. Methods: Seven golfers from a college team (handicap: 0--12) were recruited to complete a swing speed test and impact precision test using a 5-iron club, A force plate and electromyography (EMG) system were used to collect data in the swing speed test to compare the difference between two motion sequences. High speed video cameras were used to determine the displacement of rotation center for impact precision test. Results: The results showed a significant difference (p 〈 0.01) in clubhead speed with different motion sequences and muscle contraction patterns. In the impact precision test, the displacement of the rotation center which defined as the inner center point of the C7 was significantly different (p 〈 0.05) between different ball impacted marks on club face. Conclusion: The vertical peak ground reaction force on left foot occurring before impact and the left latissimus dorsi contracting prior to the right pectoralis major represent a superior skill by allowing the club to strike the ball with normal collision at a faster speed.展开更多
With the increasing necessities for reliable printed circuit board(PCB) product, there has been a considerable demand for high speed and high precision vision positioning system. To locate a rectangular lead component...With the increasing necessities for reliable printed circuit board(PCB) product, there has been a considerable demand for high speed and high precision vision positioning system. To locate a rectangular lead component with high accuracy and reliability, a new visual positioning method was introduced. Considering the limitations of Ghosal sub-pixel edge detection algorithm, an improved algorithm was proposed, in which Harris corner features were used to coarsely detect the edge points and Zernike moments were adopted to accurately detect the edge points. Besides, two formulas were developed to determine the edge intersections whose sub-pixel coordinates were calculated with bilinear interpolation and conjugate gradient method. The last experimental results show that the proposed method can detect the deflection and offset, and the detection errors are less than 0.04° and 0.02 pixels.展开更多
This paper presents a novel precision delay circuit design for high-speed data acquisition systems. Many studies have suggested that various advanced electronic measurement apparatuses require that the delay circuit s...This paper presents a novel precision delay circuit design for high-speed data acquisition systems. Many studies have suggested that various advanced electronic measurement apparatuses require that the delay circuit should have a high precision and a short delay interval. Practically, however, such measurement apparatuses are low in preci- sion and long in delay interval at present. The structure and function of a data acquisition system is introduced first; then the principle of ramp-based precision delay circuits and the digitally programmable delay generator is studied and the precision delay circuit is designed. The authors also demonstrated 8-bit programmable delay circuits with a timing pre- cision of 10 ps. Therefore the programmable precision delay circuit here presented has a higher precision, shorter inter- val and more detectable function than any other precision delay circuit.展开更多
文摘Static corrections using the conventional method are basically conducted in two steps, the weathering correction followed by the correction from the top of the sub-weathering to the unified datum. However, the conventional method fails to well deal with statics problems in case the top of the sub-weathering is sharply undulated and the lateral velocity of the sub-weathering varies significantly. This brings us to the introduction of a smooth intermediate reference datum (IRD) located under the top of the sub-weathering, which helps to further increase the accuracy of statics based on the weathering corrections, and ensures the imaging quality. Good results based on the IRD technique have been achieved in the complex areas in western China. This paper discusses the IRD functions, its application requirements, and selection of related parameters. Some typical sections for comparison are also given in this paper.
文摘Background: To understand an effective golf swing, both swing speed and impact precision must be thoroughly and simultaneously examined. The aim of this study was to perform both swing speed test and impact precision test to ascertain what swing type determines an effective impact. Methods: Seven golfers from a college team (handicap: 0--12) were recruited to complete a swing speed test and impact precision test using a 5-iron club, A force plate and electromyography (EMG) system were used to collect data in the swing speed test to compare the difference between two motion sequences. High speed video cameras were used to determine the displacement of rotation center for impact precision test. Results: The results showed a significant difference (p 〈 0.01) in clubhead speed with different motion sequences and muscle contraction patterns. In the impact precision test, the displacement of the rotation center which defined as the inner center point of the C7 was significantly different (p 〈 0.05) between different ball impacted marks on club face. Conclusion: The vertical peak ground reaction force on left foot occurring before impact and the left latissimus dorsi contracting prior to the right pectoralis major represent a superior skill by allowing the club to strike the ball with normal collision at a faster speed.
基金Project(51175242)supported by the National Natural Science Foundation of ChinaProject(BA2012031)supported by the Jiangsu Province Science and Technology Foundation of China
文摘With the increasing necessities for reliable printed circuit board(PCB) product, there has been a considerable demand for high speed and high precision vision positioning system. To locate a rectangular lead component with high accuracy and reliability, a new visual positioning method was introduced. Considering the limitations of Ghosal sub-pixel edge detection algorithm, an improved algorithm was proposed, in which Harris corner features were used to coarsely detect the edge points and Zernike moments were adopted to accurately detect the edge points. Besides, two formulas were developed to determine the edge intersections whose sub-pixel coordinates were calculated with bilinear interpolation and conjugate gradient method. The last experimental results show that the proposed method can detect the deflection and offset, and the detection errors are less than 0.04° and 0.02 pixels.
文摘This paper presents a novel precision delay circuit design for high-speed data acquisition systems. Many studies have suggested that various advanced electronic measurement apparatuses require that the delay circuit should have a high precision and a short delay interval. Practically, however, such measurement apparatuses are low in preci- sion and long in delay interval at present. The structure and function of a data acquisition system is introduced first; then the principle of ramp-based precision delay circuits and the digitally programmable delay generator is studied and the precision delay circuit is designed. The authors also demonstrated 8-bit programmable delay circuits with a timing pre- cision of 10 ps. Therefore the programmable precision delay circuit here presented has a higher precision, shorter inter- val and more detectable function than any other precision delay circuit.