Under hypersonic flight conditions,the sharp cowl-lip leading edges have to be blunted because of the severe aerodynamic heating.This paper proposes four cowl-lip blunting methods and studies the corresponding flow ch...Under hypersonic flight conditions,the sharp cowl-lip leading edges have to be blunted because of the severe aerodynamic heating.This paper proposes four cowl-lip blunting methods and studies the corresponding flow characteristics and performances of the generic hypersonic inlets by numerical simulation under the design conditions of a flight Mach number of 6 and an altitude of 26 km.The results show that the local shock interference patterns in the vicinity of the blunted cowl-lips have a substantial influence on the flow characteristics of the hypersonic inlets even though the blunting radius is very small,which contribute to a pronounced degradation of the inlet performance.The Equal Length blunting Manner(ELM)is the most optimal in that a nearly even reflection of the ramp shock produces an approximately straight and weak cowl reflection shock.The minimal total pressure loss,the lowest cowl drag,maximum mass-capture and the minimal aeroheating are achieved for the hypersonic inlet.For the other blunting manners,the ramp shock cannot reflect evenly and produces more curved cowl reflection shock.The Type V shock interference pattern occurs for the Cross Section Cutting blunting Manner(CSCM)and the strongest cowl reflection shock gives rise to the largest flow loss and drag.The cowl-lip blunted by the other two blunting manners is subjected to the shock interference pattern that transits with an increase in the blunting radius.Accordingly,the peak heat flux does not fall monotonously with the blunting radius increasing.Moreover,the cowl-lip surface suffers from severe aerothermal load when the shear layer or the supersonic jet impinges on the wall.展开更多
A visualization study on the behavior of bubbles has been carried out for pool boiling of R141b on a horizontal transparent heater at pressure 0.1 MPa. The behaviors of bubbles were recorded by a high-speed camera pla...A visualization study on the behavior of bubbles has been carried out for pool boiling of R141b on a horizontal transparent heater at pressure 0.1 MPa. The behaviors of bubbles were recorded by a high-speed camera placed beneath the heater surface. The departure diameter, departure time of bubbles and nucleation site density at different heat flux were obtained. The visualization results show that bubble departure diameter and departure time decrease, while the nucleation site density increases as the heat flux increases. R is also observed that there is no liquid recruited into the microlayer in the experiment. Based on the experimental results, boiling curve for R141b was predicted by using the dynamic microlayer model. As a resuR, the agreement between the predictive result based on the dynamic microlayer model and the experiment data for boiling curve of R141b is good at high heat flux.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.90716014 and 91216115)
文摘Under hypersonic flight conditions,the sharp cowl-lip leading edges have to be blunted because of the severe aerodynamic heating.This paper proposes four cowl-lip blunting methods and studies the corresponding flow characteristics and performances of the generic hypersonic inlets by numerical simulation under the design conditions of a flight Mach number of 6 and an altitude of 26 km.The results show that the local shock interference patterns in the vicinity of the blunted cowl-lips have a substantial influence on the flow characteristics of the hypersonic inlets even though the blunting radius is very small,which contribute to a pronounced degradation of the inlet performance.The Equal Length blunting Manner(ELM)is the most optimal in that a nearly even reflection of the ramp shock produces an approximately straight and weak cowl reflection shock.The minimal total pressure loss,the lowest cowl drag,maximum mass-capture and the minimal aeroheating are achieved for the hypersonic inlet.For the other blunting manners,the ramp shock cannot reflect evenly and produces more curved cowl reflection shock.The Type V shock interference pattern occurs for the Cross Section Cutting blunting Manner(CSCM)and the strongest cowl reflection shock gives rise to the largest flow loss and drag.The cowl-lip blunted by the other two blunting manners is subjected to the shock interference pattern that transits with an increase in the blunting radius.Accordingly,the peak heat flux does not fall monotonously with the blunting radius increasing.Moreover,the cowl-lip surface suffers from severe aerothermal load when the shear layer or the supersonic jet impinges on the wall.
文摘A visualization study on the behavior of bubbles has been carried out for pool boiling of R141b on a horizontal transparent heater at pressure 0.1 MPa. The behaviors of bubbles were recorded by a high-speed camera placed beneath the heater surface. The departure diameter, departure time of bubbles and nucleation site density at different heat flux were obtained. The visualization results show that bubble departure diameter and departure time decrease, while the nucleation site density increases as the heat flux increases. R is also observed that there is no liquid recruited into the microlayer in the experiment. Based on the experimental results, boiling curve for R141b was predicted by using the dynamic microlayer model. As a resuR, the agreement between the predictive result based on the dynamic microlayer model and the experiment data for boiling curve of R141b is good at high heat flux.