To overcome the limitations of structural height imposed by airspace restrictions in the design of maintenance hangar roofs with long spans,a new diagonal truss roof structural system is introduced for the first time....To overcome the limitations of structural height imposed by airspace restrictions in the design of maintenance hangar roofs with long spans,a new diagonal truss roof structural system is introduced for the first time.In the design of China Southern Airlines No.1 Hangar,4 main trusses were arranged diagonally along the depth direction,forming a W-shape truss.3 lineshaped trusses were arranged along the span direction,and double-layer space latticed structure is laid on them.The design optimized the height of the 183 m+222 m super long-span roof to 11.5 m,the maximum dimension the site could provide,so that the building height is within the permitted 40m.The steel consumption of the roof is only 165 kg/m^(2).The installation of diagonal trusses changed the unidirectional load transmission path of the roof and enhanced the spatial load transmission,effectively relieving the burden on the gate-side truss.This design enables the implementation of a maintenance hangar with a 222 m-span and heavy roof within the constraints of low airspace height.展开更多
文摘To overcome the limitations of structural height imposed by airspace restrictions in the design of maintenance hangar roofs with long spans,a new diagonal truss roof structural system is introduced for the first time.In the design of China Southern Airlines No.1 Hangar,4 main trusses were arranged diagonally along the depth direction,forming a W-shape truss.3 lineshaped trusses were arranged along the span direction,and double-layer space latticed structure is laid on them.The design optimized the height of the 183 m+222 m super long-span roof to 11.5 m,the maximum dimension the site could provide,so that the building height is within the permitted 40m.The steel consumption of the roof is only 165 kg/m^(2).The installation of diagonal trusses changed the unidirectional load transmission path of the roof and enhanced the spatial load transmission,effectively relieving the burden on the gate-side truss.This design enables the implementation of a maintenance hangar with a 222 m-span and heavy roof within the constraints of low airspace height.