组合生物技术对黑色水体净化修复研究 被引量:2
1
作者 魏武强 《工程建设与设计》 2019年第15期179-181,共3页
黑色水体是由水中有机物进行厌氧分解造成的。不仅严重破坏我国水体平衡,还会打破水体平衡。因此,对于黑色水体的综合治理已迫在眉睫。论文从黑色水体的类型、成因以及评价指标入手,结合具体实例,系统分析了组合生物技术对黑色水体的治... 黑色水体是由水中有机物进行厌氧分解造成的。不仅严重破坏我国水体平衡,还会打破水体平衡。因此,对于黑色水体的综合治理已迫在眉睫。论文从黑色水体的类型、成因以及评价指标入手,结合具体实例,系统分析了组合生物技术对黑色水体的治理研究。 展开更多
关键词 组合生物技术 黑色水体 净化修复
下载PDF
DECOMPOSITION OF BLACK LIQUOR BY ULTRASOUND PROCESS 被引量:3
2
作者 WUXiaohui ZHOUShan LUXiaohua 《Chinese Journal of Reactive Polymers》 2004年第1期22-28,共7页
Ultrasound (US)-induced cavitation is an effective way in oxidizing organic contaminants in wastewater either as the independent operation unit or in combination with other oxidation methods. In this paper, black liqu... Ultrasound (US)-induced cavitation is an effective way in oxidizing organic contaminants in wastewater either as the independent operation unit or in combination with other oxidation methods. In this paper, black liquor and filtrate after acidifying and settling were sonicated. The effect of working parameters on ultrasonic degradation of black liquor, such as different combination methods, frequency, power supply, initial concentration, pH, duration time, ionic strength and catalyst were studied. The results were as follows: (1) At the conditions of 40kHz, 100W, 4h, pH at 6 and temperature 30?℃, utilizing US/US-H2O2/US-Fenton, weak-orange filtrate turned to colloid with the increase of time and little sediment produced after settling. Especially filtrate came to be milk white collides and upper water approached to nearly achromatic by US-Fenton. Compared with the US, US-H2O2/US-Fenton COD (Chemical oxidation demand) removal ratio can increase 15%, 30% respectively. Because of more hydroxyl radicals produced in the reaction process; (2) At the condition of 100W and 4h, the degradation efficiency of black liquor was better at 40kHz over at 20kHz. Moreover black liquor can be biodegraded easily. Those based on that the big molecule of contaminants in aqueous solution can be changed into the little molecule with ultrasound (3) At the condition of 40kHz and 4h, the COD removal ratio of black liquor was more higher at 60W than at 80W, while the removal ratio of COD at 60W was nearly close to the ratio at 100W; (4) The initial concentration of black liquor influenced the effect of sonochemical degradation; (5) The variation of pH had no effect on degradation; (6) The longer the duration time, the greater the removal ratio of COD. But this ratio increased slowly after 4h; (7) Adding 0.2g/L NaCl to change the ionic strength of the black liquor, the COD removal ratio can increase 10%; (8) The degradation rates increased by the coexistent catalysts of TiO2, Co2+ and Ag+. 展开更多
关键词 Ultrasound (US) Black liquor DEGRADATION Different combination methods.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部