期刊文献+
共找到33,830篇文章
< 1 2 250 >
每页显示 20 50 100
Non-crossing Quantile Regression Neural Network as a Calibration Tool for Ensemble Weather Forecasts 被引量:1
1
作者 Mengmeng SONG Dazhi YANG +7 位作者 Sebastian LERCH Xiang'ao XIA Gokhan Mert YAGLI Jamie M.BRIGHT Yanbo SHEN Bai LIU Xingli LIU Martin Janos MAYER 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第7期1417-1437,共21页
Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantil... Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantile regression(QR)is highly competitive in terms of both flexibility and predictive performance.Nevertheless,a long-standing problem of QR is quantile crossing,which greatly limits the interpretability of QR-calibrated forecasts.On this point,this study proposes a non-crossing quantile regression neural network(NCQRNN),for calibrating ensemble NWP forecasts into a set of reliable quantile forecasts without crossing.The overarching design principle of NCQRNN is to add on top of the conventional QRNN structure another hidden layer,which imposes a non-decreasing mapping between the combined output from nodes of the last hidden layer to the nodes of the output layer,through a triangular weight matrix with positive entries.The empirical part of the work considers a solar irradiance case study,in which four years of ensemble irradiance forecasts at seven locations,issued by the European Centre for Medium-Range Weather Forecasts,are calibrated via NCQRNN,as well as via an eclectic mix of benchmarking models,ranging from the naïve climatology to the state-of-the-art deep-learning and other non-crossing models.Formal and stringent forecast verification suggests that the forecasts post-processed via NCQRNN attain the maximum sharpness subject to calibration,amongst all competitors.Furthermore,the proposed conception to resolve quantile crossing is remarkably simple yet general,and thus has broad applicability as it can be integrated with many shallow-and deep-learning-based neural networks. 展开更多
关键词 ensemble weather forecasting forecast calibration non-crossing quantile regression neural network CORP reliability diagram POST-PROCESSING
下载PDF
Evaluation of the calibration factors of neutron dose rate meters in a 241Am–Be neutron field 被引量:2
2
作者 Thiem Ngoc Le Sy Minh Tuan Hoang +1 位作者 Quynh Ngoc Nguyen Hoai-Nam Tran 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第9期18-23,共6页
Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of... Calibrations were performed for three types of neutron ambient dose equivalent rate meters, i.e., Aloka TPS-451C (Hitachi), KSAR1U.06 (Baltic Scientific Instruments), and Model 12-4 (Ludlum), using a standard field of a 241Am–Be source. The measured total neutron ambient dose equivalent rates, H*(10)' tot, were analyzed to obtain the direct neutron ambient dose equivalent rates, H*(10)' dir, using the ISO 8529-2-recommended generalized- fit method, semiempirical fit method, and reducedfitting method (RFM) fit methods. The calibration factor (CF), defined as the ratio between the conventional true value of the neutron ambient dose equivalent rates in a free field, H*(10)' FF, and H*(10)' dir, was evaluated as one of the important characteristics of the neutron meters in the present work. The fitting results show that the H*(10)' dir values of the meters are in good agreement within the theoretical data within 4%. The averaged CFs of the three neutron meters were evaluated as 0:99 ± 0:01, 1:00 ± 0.03;and 0:99 ± 0:08, respectively. The largest standard uncertainty of these values was determined to be approximately 18.47%(k =1). The standard uncertainty of the CFs obtained using the RFM method was less than 4.23%(k=1), which is the smallest uncertainty among the three methods. 展开更多
关键词 NEUTRON METER calibration FACTOR ^241 Am–Be SOURCE
下载PDF
Model calibration concerning risk coefficients of driving safety field model 被引量:5
3
作者 LI Yang WANG Jian-qiang WU Jian 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第6期1494-1502,共9页
Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model ba... Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model based on grey relation degree analysis to calibrate risk coefficients of DSF model. To solve the optimum solution, a genetic algorithm is employed. Finally, the DSF model is verified through a real-world driving experiment. Results show that the DSF model is consistent with driver's hazard perception and more sensitive than TTC. Moreover, the proposed DSF model offers a novel way for criticality assessment and decision-making of advanced driver assistance systems and intelligent connected vehicles. 展开更多
关键词 intelligent CONNECTED vehicles advanced DRIVER ASSISTANCE systems (ADAS) driving risk assessment driving safety field (DSF) model parameter calibration GREY RELATION degree
下载PDF
A real-time calibration method based on time-to-digital converter for accelerator timing system
4
作者 Qi-Hao Duan Liang Ge +2 位作者 Yan-Hao Jia Jie-Yu Zhu Wei Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期127-140,共14页
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov... The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF. 展开更多
关键词 HIAF White rabbit calibration system Time-to-digital converter(TDC)
下载PDF
An approach to measure the pose of RHJD4-1 arc welding robot for calibration 被引量:1
5
作者 宋月娥 吴林 +1 位作者 田劲松 戴明 《China Welding》 EI CAS 2002年第1期5-8,共4页
A measurement setup used for robot calibration was designed to meet the requirement of off line programming technique. The robot end effector pose (position and orientation) can be calculated indirectly by using thi... A measurement setup used for robot calibration was designed to meet the requirement of off line programming technique. The robot end effector pose (position and orientation) can be calculated indirectly by using this setup. The setup has been applied to RHJD4 1 arc welding robot. The experimental results show the method of pose measuring using the measurement setup is simple and reliable to finish pose measuring for robot calibration. In addition, the setup can measure the position repeatability of robot. 展开更多
关键词 arc welding robot calibration position and orientation measurement REPEATABILITY
下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
6
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
A Weakly-Supervised Crowd Density Estimation Method Based on Two-Stage Linear Feature Calibration
7
作者 Yong-Chao Li Rui-Sheng Jia +1 位作者 Ying-Xiang Hu Hong-Mei Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第4期965-981,共17页
In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd dat... In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd datasets,and propose a crowd density estimation method based on weakly-supervised learning,in the absence of crowd position supervision information,which directly reduces the number of crowds by using the number of pedestrians in the image as the supervised information.For this purpose,we design a new training method,which exploits the correlation between global and local image features by incremental learning to train the network.Specifically,we design a parent-child network(PC-Net)focusing on the global and local image respectively,and propose a linear feature calibration structure to train the PC-Net simultaneously,and the child network learns feature transfer factors and feature bias weights,and uses the transfer factors and bias weights to linearly feature calibrate the features extracted from the Parent network,to improve the convergence of the network by using local features hidden in the crowd images.In addition,we use the pyramid vision transformer as the backbone of the PC-Net to extract crowd features at different levels,and design a global-local feature loss function(L2).We combine it with a crowd counting loss(LC)to enhance the sensitivity of the network to crowd features during the training process,which effectively improves the accuracy of crowd density estimation.The experimental results show that the PC-Net significantly reduces the gap between fullysupervised and weakly-supervised crowd density estimation,and outperforms the comparison methods on five datasets of Shanghai Tech Part A,ShanghaiTech Part B,UCF_CC_50,UCF_QNRF and JHU-CROWD++. 展开更多
关键词 Crowd density estimation linear feature calibration vision transformer weakly-supervision learning
下载PDF
A new calibration method for radon detector in seismic systems
8
作者 Hongwei Ren Yaowei Liu 《Earthquake Science》 2024年第5期445-458,共14页
Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector ... Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems,such as aging and scrap,acquisition difficulties,high supervision costs,and transportation limitations of radon sources.As a result,a large number of radon detectors cannot be accurately calibrated regularly,seriously affecting the accuracy and reliability of radon observation data in China.To solve this problem,a new calibration method for radon detectors was established.The advantage of this method is that the dangerous radioactive substance,i.e.,the radon source,can be avoided,but only“standard instruments”and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration.This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China.The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5%compared with that by the traditional method,which meets the requirements of seismic observation systems,confirming the reliability of the new method.This new method can completely replace the traditional calibration method of using a radon source in seismic systems. 展开更多
关键词 radon detector calibration “standard instrument” scintillation chamber radon source
下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
9
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
下载PDF
Mathematical Modeling,Field Calibration and Numerical Simulation of Low-Speed Mixed Traffic Flow in Cities 被引量:1
10
作者 Doctoral Candidate: Feng SuweiAdvisor: Prof. Dai Shiqiang 《Advances in Manufacturing》 SCIE CAS 1998年第2期86-88,共3页
Withtherapiddevelopmentoftransportationandautomobileindustry,theconflictbetweenmotormanufactureandhighwaycon... Withtherapiddevelopmentoftransportationandautomobileindustry,theconflictbetweenmotormanufactureandhighwayconstructionbecomess... 展开更多
关键词 low speed mixed traffic flow in cities mathematical modeling numerical simulation field calibration vehicular parking traffic light control
下载PDF
Calibration of CO and CO2 Monitors Used in Periodic Inspection of Vehicles at Fixed Stations for Environmental Control
11
作者 Adel Bassuoni Shehata Abdulrahman Rashed Al Askar +2 位作者 Najjy Hamad Al Yami Abdullah Suleiman Al Owaysi Sultan K. Alharbi 《Green and Sustainable Chemistry》 2024年第2期29-41,共13页
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri... Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment. 展开更多
关键词 MONITORS Periodic Inspection CO/CO2 calibration LINEARITY Precision Accuracy
下载PDF
Parameter calibration of the tensile-shear interactive damage constitutive model for sandstone failure
12
作者 Yun Shu Zheming Zhu +4 位作者 Meng Wang Weiting Gao Fei Wang Duanying Wan Yuntao Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1153-1174,共22页
The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The bas... The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The basic parameters of sandstone are determined through a series of static and dynamic tests,including uniaxial compression,Brazilian disc,triaxial compression under varying confining pressures,hydrostatic compression,and dynamic compression and tensile tests with a split Hopkinson pressure bar.Based on the sandstone test results from this study and previous research,a step-by-step procedure for parameter calibration is outlined,which accounts for the categories of the strength surface,equation of state(EOS),strain rate effect,and damage.The calibrated parameters are verified through numerical tests that correspond to the experimental loading conditions.Consistency between numerical results and experimental data indicates the precision and reliability of the calibrated parameters.The methodology presented in this study is scientifically sound,straightforward,and essential for improving the TSID model.Furthermore,it has the potential to contribute to other rock constitutive models,particularly new user-defined models. 展开更多
关键词 Damage constitutive model Parameter calibration Rock modeling SANDSTONE Dynamic impact load Tensile-shear interactive damage(TSID)model
下载PDF
Global Calibration Method for Monocular Multi-View System Using Rotational Dual-Target
13
作者 Kun He Hongwei He 《Open Journal of Applied Sciences》 2024年第5期1192-1203,共12页
To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calib... To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calibration method is proposed for the geometric properties of rotational correlation motion and the absolute orientation of the field of view without over lap. Firstly, a dual-camera system is constructed for photographing and collecting the rotating image sequence of two flat targets rigidly connected by a long rod at different positions, and based on the known parameters, such as, target feature image, world coordinates, camera internal parameters and so on, then the global PnP optimization method is used to solve the rotation axis and the reference point at different positions;Then, the absolute orientation matrix is constructed based on the parameters of rotation axis, reference point and connecting rod length obtained by this method. In the end, the singular value decomposition method is used to find the optimal rotation matrix, and then get the translation matrix. It’s shown based on simulation and actual tests that in comparison with the existing methods, the maximum attitude and pose errors is 0.0083˚ and 0.3657 mm, respectively, which improves the accuracy by 27.8% and 24.4%, respectively. The calibration device in this paper is simple, and there are no parallel, vertical and coplanar requirements between multiple rotating positions. At the same time, in view of the calibration accuracy, the accuracy requirements of most application scenarios can be met. 展开更多
关键词 Machine Vision Accurate Demarcating Global calibration Absolute Orientation
下载PDF
Calibration of a neutron dose rate meter in various neutron standard fields 被引量:1
14
作者 Tuan Khai Nguyen Hoai-Nam Tran +4 位作者 Quynh Ngoc Nguyen Thi My Linh Dang Van Loat Bui Thiansin Liamsuwan Ngoc-Thiem Le 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第6期75-82,共8页
This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and ... This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%. 展开更多
关键词 Neutron standard fields Neutron dose rate meter calibration factor 252Cf source 241AmBe source
下载PDF
Calibration and Validation of Decision Support System for Agro-Technology Transfer Model for Simulating Growth and Yield of Maize in Bangladesh
15
作者 F. Ahmed Apurba K. Choudhury +14 位作者 S. Akhter M. A. Aziz Jatish C. Biswas M. Maniruzzaman M. Main Uddin Miah M. M. Rahman M. A. H. S. Jahan Imrul Mosaddek Ahmed R. Sen S. Ishtiaque A. F. M. Tariqul Islam M. M. Haque M. Belal Hossain Naveen Kalra M. Hafijur Rahman 《American Journal of Plant Sciences》 2017年第7期1632-1645,共14页
Maize is an emerging important crop in Bangladesh because of its high yield potential and economic profitability compared to rice and wheat crops. There is a need to understand the growth and yield behavior of this cr... Maize is an emerging important crop in Bangladesh because of its high yield potential and economic profitability compared to rice and wheat crops. There is a need to understand the growth and yield behavior of this crop in varying production environments of Bangladesh. Crop model such as Decision Support System For Agro-technology Transfer (DSSAT) version 4.6 (DSSAT hereafter) can be utilized cost effectively to study the performances of maize under different production environments. It needs to calibrate and validate DSSAT model for commonly cultivated maize cultivars in Bangladesh and subsequently take the model to various applications, including inputs and agronomic management options and climate change that impacts analyses. So, the present study was undertaken to firstly calibrate DSSAT model for popular four hybrid maize cultivars (BARI Hybrid Maize-7, BARI Hybrid Maize-9, Pioneer 30B07 and NK-40). Subsequently, it proceeded with the validation with independent field data sets for evaluating their growth performances. The genetic coefficients for these cultivars were evaluated by using Genotype coefficient calculator (GENCALC) and Generalized likelihood uncertainty estimation (GLUE) module of DSSAT on the basis of first season experiment. The performance of the model was satisfactory and within the significant limits. After calibration, the model was tested for its performance through validation procedure by using second season data. The model performed satisfactorily through phenology, biomass, leaf area index (LAI) and grain yield. Phenology, as estimated through days to flower initiation and maturity, was in good agreement, although simulated results were slightly over predicted compared to observed values but within the statistical significance limit...when compared with observed values at specific growth stages of the crop. The final yield values (10.12 to 10.59 t·ha-1) were in close agreement with the observed values (10.16 to 10.94 t·ha-1), as the percentage error was within tolerable limit (0.39% to 6.81%). The model has been successfully calibrated and validated for Gazipur environment and now can be used for climate change impact studies for similar environments in Bangladesh. 展开更多
关键词 calibration VALIDATION DSSAT Model and MAIZE
下载PDF
Calibration and data restoration of light field modulated imaging spectrometer
16
作者 Li-Juan Su Qiang-Qiang Yan +2 位作者 Yan Yuan Shi-Feng Wang Yu-Jian Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期179-186,共8页
A light field modulated imaging spectrometer (LFMIS) can acquire the spatial-spectral datacube of targets of interest or a scene in a single shot. The spectral information of a point target is imaged on the pixels c... A light field modulated imaging spectrometer (LFMIS) can acquire the spatial-spectral datacube of targets of interest or a scene in a single shot. The spectral information of a point target is imaged on the pixels covered by a microlens. The pixels receive spectral information from different spectral filters to the diffraction and misalignments of the optical components. In this paper, we present a linear spectral multiplexing model of the acquired target spectrum. A calibration method is proposed for calibrating the center wavelengths and bandwidths of channels of an LFMIS system based on the liner-variable filter (LVF) and for determining the spectral multiplexing matrix. In order to improve the accuracy of the restored spectral data, we introduce a reconstruction algorithm based on the total least square (TLS) approach. Simulation and experimental results confirm the performance of the spectrum reconstruction algorithm and validate the feasibility of the proposed calibrating scheme. 展开更多
关键词 light field modulated imaging spectrometer linear-variable filter spectral calibration spectral re-construction
下载PDF
Field measurements for calibration of simplified models of the stiffening effect of infill masonry walls in high-rise RC framed and shear-wall buildings
17
作者 Zhou Yun Pei Yilin +2 位作者 Zhou Yi Hyeon-Jong Hwang Yi Weijian 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期87-104,共18页
As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplif... As a type of nonstructural component, infill walls play a significant role in the seismic behavior of high-rise buildings. However, the stiffness of the infill wall is generally either ignored or considered by simplified empirical criteria that lead to a period shortening. The difference can be greatly decreased by using a structural identification methodology. In this study, an ambient vibration test was performed on four on-site reinforced concrete high-rise buildings, and the design results were compared with the PKPM models using corresponding finite element(FE) models. A diagonal strut model was used to simulate the behavior of the infill wall, and the identified modal parameters measured from the on-site test were employed to calibrate the parameters of the diagonal strut in the FE models. The SAP2000 models with calibrated elastic modulus were used to evaluate the seismic response in the elastic state. Based on the load-displacement relationship of the infill wall, nonlinear dynamic analysis models were built in PERFORM-3 D and calibrated using the measured modal periods. The analysis results revealed that the structural performance under small/large earthquake records were both strengthened by infill walls, and the contribution of infill walls should be considered for better accuracy in the design process. 展开更多
关键词 high-rise building ambient vibration test model calibration infi ll wall seismic performance nonlinear dynamic analysis
下载PDF
Calibration of Camera with Large Field-of-View Based on Flexible Planar Target
18
作者 Ju Huo Wen-Bo Dong +1 位作者 Ning Yang Wu-Kang Lin 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第4期14-20,共7页
For high precision calibration of camera with large field-of-view,massive calibration points will be needed if traditional methods are selected,which makes the calibration complex and time-consuming.In order to solve ... For high precision calibration of camera with large field-of-view,massive calibration points will be needed if traditional methods are selected,which makes the calibration complex and time-consuming.In order to solve this problem,a calibration method based on flexible planar target is proposed.In this method,distortion factor is firstly acquired by the invariance of cross ratio,and existing feature points are adjusted with the distortion factor.Then,a large number of points that will be used for the calibration are constructed with the adjusted feature points.Simultaneously,Tsai method is modified so as to reduce the complexity of calibration,which makes the process linear.The simulation and real experiments show that the method proposed in this paper is simple,linear,accurate and robust,and the precision of this method is close to that of Tsai method using abundant points.The method can satisfy the requirement of high precision calibration for camera with large field-of-view. 展开更多
关键词 large field-of-view calibration distortion factor flexible planar target linear two-step method
下载PDF
Integration of Tracer Test Data to Refine Geostatistical Hydraulic Conductivity Fields Using Sequential Self-Calibration Method 被引量:5
19
作者 胡晓农 蒋小伟 万力 《Journal of China University of Geosciences》 SCIE CSCD 2007年第3期242-256,共15页
On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the m... On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the methods are not suited to directly integrate dynamic production data, such as, hydraulic head and solute concentration, into the study of conductivity distribution. These data, which record the flow and transport processes in the medium, are closely related to the spatial distribution of hydraulic conductivity. In this study, a three-dimensional gradient-based inverse method--the sequential self-calibration (SSC) method--is developed to calibrate a hydraulic conductivity field, initially generated by a geostatistical simulation method, conditioned on tracer test results. The SSC method can honor both local hydraulic conductivity measurements and tracer test data. The mismatch between the simulated hydraulic conductivity field and the reference true one, measured by its mean square error (MSE), is reduced through the SSC conditional study. In comparison with the unconditional results, the SSC conditional study creates the mean breakthrough curve much closer to the reference true curve, and significantly reduces the prediction uncertainty of the solute transport in the observed locations. Further, the reduction of uncertainty is spatially dependent, which indicates that good locations, geological structure, and boundary conditions will affect the efficiency of the SSC study results. 展开更多
关键词 sequential self-calibration tracer test hydraulic conductivity geostatistical simulation inverse problem
下载PDF
Calculation of Calibration Functions and Explosive Aftershock Magnitudes in the Near Field
20
作者 LiXuezheng WangHaijun LeiJun 《Earthquake Research in China》 2003年第4期305-314,共10页
The current calibration function used in calculating the magnitude of natural earthquakes within 5km is a constant; a fact that causes several serious difficulties for the calculation of the magnitude of small and sha... The current calibration function used in calculating the magnitude of natural earthquakes within 5km is a constant; a fact that causes several serious difficulties for the calculation of the magnitude of small and shallow-focus earthquakes. According to the attenuation law of explosions and the propagation theory of elastic waves, the calibration function is calculated for near field quakes from 0km to 5km. Magnitudes of two aftershock sequences are calculated. The magnitudes of most explosion earthquakes are small, ranging mainly from magnitude -0.5 to 1.0. The M-t chart of the explosive aftershocks is completely different from that of strong earthquake aftershocks. It not only shows positive columnar lines indicating large magnitudes but also short negative columnar lines indicating small magnitudes. 展开更多
关键词 Explosion aftershocks calibration function Magnitude distribution
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部