The radiant tube burner was modeled and analyzed by the numerical simulation method to investigate the influence factors and rules of NO_(x) emissions in a W-type radiant tube.These factors,which include air preheatin...The radiant tube burner was modeled and analyzed by the numerical simulation method to investigate the influence factors and rules of NO_(x) emissions in a W-type radiant tube.These factors,which include air preheating temperature,excess air coefficient,and fuel gas composition,were modified to study their effects on NO_(x) emissions under varying working conditions.Simulation results were compared with the theoretical calculation value based on chemical reaction equilibrium theory and the onsite experimental value to verify the simulation accuracy.The results show that NO_(x) emissions rise with increasing air preheating temperatures.NO_(x) production increases to an extreme value and then decreases during the oxygen-poor to oxygen-enriched process with the rise of the excess air coefficient.Enhancing the proportion of coke oven gas in the fuel gas raises the combustion temperature as well as the NO_(x) discharge.Both the thermal efficiency and NO_(x) emissions should be balanced.Therefore,the recommended values based on the simulation results are as follows:the air preheating temperature should not exceed 400℃,the excess air coefficient should be between 1.1 and 1.2,and the volume fraction of the coke oven gas should not exceed 30%.展开更多
以夏热冬冷地区的办公建筑为例,利用瞬态系统仿真程序(transient system simulation program, TRNSYS)构建主动式相变蓄能地板模块,建立了主动式相变蓄能地板空调系统和常规风机盘管加新风空调系统的仿真模型,对其节能性和经济性进行模...以夏热冬冷地区的办公建筑为例,利用瞬态系统仿真程序(transient system simulation program, TRNSYS)构建主动式相变蓄能地板模块,建立了主动式相变蓄能地板空调系统和常规风机盘管加新风空调系统的仿真模型,对其节能性和经济性进行模拟计算.以典型日和供冷季晚间蓄冷运行工况为条件,研究冷冻水温对主动式相变蓄能地板的蓄释能特性、室温波动与热泵制冷系数的影响.结果表明:夜间相变蓄冷工况下,在满足每平方米冷负荷为74.78 W情况下,9℃为最佳供水水温;采取晚间低电价时段间歇运行蓄冷热泵的方案,能够有效提高热泵运行时的制冷系数,并降低运行费用;主动式相变蓄能地板空调系统供冷季的能耗相比于常规风机盘管加新风空调系统减少30.5%,运行费用减少44.24%,夏季制冷综合能效比达到了2.38.展开更多
辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的...辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的室内热舒适和房间能耗。结果表明:3种辐射供冷模型下,室内的相对湿度都在40%~60%舒适范围内;墙面和顶板辐射供冷的预测平均投票(Predicted Mean Vote, PMV)值在0.25~0.50之间,而预测不满意百分数(Predicted Percentage of Dissatisfied, PPD)值小于10%,PMV-PPD指标达到了Ⅰ级,热舒适性较好;在设计日运行时间内,地面、顶板、墙面辐射供冷的总能耗分别为5.59、6.23、6.16 kW·h,地面辐射供冷的节能性最好。展开更多
文摘The radiant tube burner was modeled and analyzed by the numerical simulation method to investigate the influence factors and rules of NO_(x) emissions in a W-type radiant tube.These factors,which include air preheating temperature,excess air coefficient,and fuel gas composition,were modified to study their effects on NO_(x) emissions under varying working conditions.Simulation results were compared with the theoretical calculation value based on chemical reaction equilibrium theory and the onsite experimental value to verify the simulation accuracy.The results show that NO_(x) emissions rise with increasing air preheating temperatures.NO_(x) production increases to an extreme value and then decreases during the oxygen-poor to oxygen-enriched process with the rise of the excess air coefficient.Enhancing the proportion of coke oven gas in the fuel gas raises the combustion temperature as well as the NO_(x) discharge.Both the thermal efficiency and NO_(x) emissions should be balanced.Therefore,the recommended values based on the simulation results are as follows:the air preheating temperature should not exceed 400℃,the excess air coefficient should be between 1.1 and 1.2,and the volume fraction of the coke oven gas should not exceed 30%.
文摘辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的室内热舒适和房间能耗。结果表明:3种辐射供冷模型下,室内的相对湿度都在40%~60%舒适范围内;墙面和顶板辐射供冷的预测平均投票(Predicted Mean Vote, PMV)值在0.25~0.50之间,而预测不满意百分数(Predicted Percentage of Dissatisfied, PPD)值小于10%,PMV-PPD指标达到了Ⅰ级,热舒适性较好;在设计日运行时间内,地面、顶板、墙面辐射供冷的总能耗分别为5.59、6.23、6.16 kW·h,地面辐射供冷的节能性最好。