When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t...When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.展开更多
The purpose of this study was to further develop the constant power model of a previous study and to provide the final solution of Hill’s force-velocity equation. Forearm and whole arm rotations of three different su...The purpose of this study was to further develop the constant power model of a previous study and to provide the final solution of Hill’s force-velocity equation. Forearm and whole arm rotations of three different subjects were performed downwards (elbow and shoulder extension) and upwards (elbow and shoulder flexion) with maximum velocity. These arm rotations were recorded with a special camera system and the theoretically derived model of constant maximum power was fitted to the experimentally measured data. The moment of inertia of the arm sectors was calculated using immersion technique for determining accurate values of friction coefficients of elbow and whole arm rotations. The experiments of the present study verified the conclusions of a previous study in which theoretically derived equation with constant maximum power was in agreement with experimentally measured results. The results of the present study were compared with the mechanics of Hill’s model and a further development of Hill’s force-velocity relationship was derived: Hill’s model was transformed into a constant maximum power model consisting of three different components of power. It was concluded that there are three different states of motion: 1) the state of low speed, maximal acceleration without external load which applies to the hypothesis of constant moment;2) the state of high speed, maximal power without external load which applies to the hypothesis of constant power and 3) the state of maximal power with external load which applies to Hill’s equation. This is a new approach to Hill’s equation.展开更多
按照现代地电探测仪器的特点和技术要求,首次将 ARM 嵌入式系统引入地电信号探测领域,建立了基于ARM 的海底大地电磁数据采集系统.面向系统开发过程,提出 ARM 嵌入式系统实现的硬件和软件设计方案,初步尝试实现了地电信号数据采集...按照现代地电探测仪器的特点和技术要求,首次将 ARM 嵌入式系统引入地电信号探测领域,建立了基于ARM 的海底大地电磁数据采集系统.面向系统开发过程,提出 ARM 嵌入式系统实现的硬件和软件设计方案,初步尝试实现了地电信号数据采集仪器的低功耗、小型化和智能化.展开更多
基金supported by the Natural Science Foundation of Sichuan Province(No.2022NSFSC0405).
文摘When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved.
文摘The purpose of this study was to further develop the constant power model of a previous study and to provide the final solution of Hill’s force-velocity equation. Forearm and whole arm rotations of three different subjects were performed downwards (elbow and shoulder extension) and upwards (elbow and shoulder flexion) with maximum velocity. These arm rotations were recorded with a special camera system and the theoretically derived model of constant maximum power was fitted to the experimentally measured data. The moment of inertia of the arm sectors was calculated using immersion technique for determining accurate values of friction coefficients of elbow and whole arm rotations. The experiments of the present study verified the conclusions of a previous study in which theoretically derived equation with constant maximum power was in agreement with experimentally measured results. The results of the present study were compared with the mechanics of Hill’s model and a further development of Hill’s force-velocity relationship was derived: Hill’s model was transformed into a constant maximum power model consisting of three different components of power. It was concluded that there are three different states of motion: 1) the state of low speed, maximal acceleration without external load which applies to the hypothesis of constant moment;2) the state of high speed, maximal power without external load which applies to the hypothesis of constant power and 3) the state of maximal power with external load which applies to Hill’s equation. This is a new approach to Hill’s equation.