期刊文献+
共找到94,197篇文章
< 1 2 250 >
每页显示 20 50 100
Induced pluripotent stem cell-related approaches to generate dopaminergic neurons for Parkinson's disease
1
作者 Ling-Xiao Yi Hui Ren Woon +3 位作者 Genevieve Saw Li Zeng Eng King Tan Zhi Dong Zhou 《Neural Regeneration Research》 SCIE CAS 2025年第11期3193-3206,共14页
The progressive loss of dopaminergic neurons in affected patient brains is one of the pathological features of Parkinson's disease,the second most common human neurodegenerative disease.Although the detailed patho... The progressive loss of dopaminergic neurons in affected patient brains is one of the pathological features of Parkinson's disease,the second most common human neurodegenerative disease.Although the detailed pathogenesis accounting for dopaminergic neuron degeneration in Parkinson's disease is still unclear,the advancement of stem cell approaches has shown promise for Parkinson's disease research and therapy.The induced pluripotent stem cells have been commonly used to generate dopaminergic neurons,which has provided valuable insights to improve our understanding of Parkinson's disease pathogenesis and contributed to anti-Parkinson's disease therapies.The current review discusses the practical approaches and potential applications of induced pluripotent stem cell techniques for generating and differentiating dopaminergic neurons from induced pluripotent stem cells.The benefits of induced pluripotent stem cell-based research are highlighted.Various dopaminergic neuron differentiation protocols from induced pluripotent stem cells are compared.The emerging three-dimension-based brain organoid models compared with conventional two-dimensional cell culture are evaluated.Finally,limitations,challenges,and future directions of induced pluripotent stem cell–based approaches are analyzed and proposed,which will be significant to the future application of induced pluripotent stem cell-related techniques for Parkinson's disease. 展开更多
关键词 dopaminergic neurons induced pluripotent stem cells Parkinson's disease stem cell approaches
下载PDF
Enhancing perianal disease management with integrated physical and psychological approaches
2
作者 Uchenna E Okpete Haewon Byeon 《World Journal of Clinical Cases》 SCIE 2025年第2期59-63,共5页
This article provides a comprehensive analysis of the study by Hou et al,focusing on the complex interplay between psychological and physical factors in the postoperative recovery(POR)of patients with perianal disease... This article provides a comprehensive analysis of the study by Hou et al,focusing on the complex interplay between psychological and physical factors in the postoperative recovery(POR)of patients with perianal diseases.The study sheds light on how illness perception,anxiety,and depression significantly influence recovery outcomes.Hou et al developed a predictive model that demonstrated high accuracy in identifying patients at risk of poor recovery.The article explores the critical role of pre-operative psychological assessment,highlighting the need for mental health support and personalized recovery plans in enhancing POR quality.A multidisciplinary approach,integrating mental health professionals with surgeons,anesthesiologists,and other specialists,is emphasized to ensure comprehensive care for patients.The study’s findings serve as a call to integrate psychological care into surgical practice to optimize outcomes for patients with perianal diseases. 展开更多
关键词 Perianal disease Post-operative recovery ANXIETY DEPRESSION Pain management Emotional well-being Multidisciplinary approach
下载PDF
APPROACH TO IMPROVEMENT OF ROBOT TRAJECTORY ACCURACY BY DYNAMIC COMPENSATION 被引量:5
3
作者 WangGang RenGuoli YanXiang'an WangGuodong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第3期446-449,共4页
Some dynamic factors, such as inertial forces and friction, may affect therobot trajectory accuracy. But these effects are not taken into account in robot motion controlschemes. Dynamic control methods, on the other h... Some dynamic factors, such as inertial forces and friction, may affect therobot trajectory accuracy. But these effects are not taken into account in robot motion controlschemes. Dynamic control methods, on the other hand, require the dynamic model of robot and theimplementation of new type controller. A method to improve robot trajectory accuracy by dynamiccompensation in robot motion control system is proposed. The dynamic compensation is applied as anadditional velocity feedforward and a multilayer neural network is employed to realize the robotinverse dynamics. The complicated dynamic parameter identification problem becomes a learningprocess of neural network connecting weights under supervision. The finite Fourier series is used toactivate each actuator of robot joints for obtaining training samples. Robot control system,consisting of an industrial computer and a digital motion controller, is implemented. The system isof open architecture with velocity feedforward function. The proposed method is not model-based andcombines the advantages of close-loop position control and computed torque control. Experimentalresults have shown that the method is validatities to improve the robot trajectory accuracy. 展开更多
关键词 ROBOT Dynamic compensation Trajectory accuracy IDENTIFICATION
下载PDF
Accuracy Analysis of Gravity Model Based on Fictitious Compress Recovery Approach 被引量:3
4
作者 SHEN Wenbin TAO Benzao 《Geo-Spatial Information Science》 2007年第3期157-162,共6页
The potential field determined based on the fictitious compress recovery approach is influenced by the errors contained in the boundary (the Earth's surface or the surface corresponding to the satellite altitude) v... The potential field determined based on the fictitious compress recovery approach is influenced by the errors contained in the boundary (the Earth's surface or the surface corresponding to the satellite altitude) values. Given the boundary value with definite accuracy, the accuracy of the field determined based on the fictitious compress recovery approach is estimated, and it is theoretically shown that the determined field has the same accuracy level as the given boundary value. 展开更多
关键词 fictitious compress recovery error function error estimate accuracy of the potential field
下载PDF
An Approach to Improving the Retrieval Accuracy of Oceanic Constituents in Case Ⅱ Waters 被引量:2
5
作者 ZHANGTinglu FrankFell 《Journal of Ocean University of China》 SCIE CAS 2004年第2期220-224,共5页
In the present paper, a method is proposed to improve the performance of Artificial Neural Network (ANN) based algorithms for the retrieval of oceanic constituents in Case Ⅱ waters. The ANN-based algorithms have been... In the present paper, a method is proposed to improve the performance of Artificial Neural Network (ANN) based algorithms for the retrieval of oceanic constituents in Case Ⅱ waters. The ANN-based algorithms have been developed based on a constraint condition, which represents, to a certain degree, the correlation between suspended particulate matter (SPM) and pigment (CHL), coloured dissolved organic matter (CDOM) and CHL, as well as CDOM and SPM, found in Case Ⅱ waters. Compared with the ANN-based algorithm developed without a constraint condition, the performance of ANN-based algorithms developed with a constraint conditions is much better for the retrieval of CHL and CDOM, especially in the case of high noise levels; however, there is not significant improvement for the retrieval of SPM. 展开更多
关键词 retrieval accuracy oceanic constituents artificial neural network Case waters ocean colour remote sensing
下载PDF
Forward-Kinematics-Based Approaches for Pose Accuracy of Docking Mechanism with Joint Clearance
6
作者 李建广 丁建 +4 位作者 姚英学 许春田 荆怀靖 方红根 曹刚 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第4期365-371,共7页
Joint clearance,as an important stochastic factor,can significantly deteriorate positioning and repeatability accuracies and lower assembly quality of a 6-DOF docking mechanism.Considering pose accuracy with tradition... Joint clearance,as an important stochastic factor,can significantly deteriorate positioning and repeatability accuracies and lower assembly quality of a 6-DOF docking mechanism.Considering pose accuracy with traditional error model that possesses inherent imprecision,both probabilistic and deterministic approaches based on forward kinematics are presented to analyze comprehensive pose error(CPE)in simulation.Results indicate an identical trend emerges for each CPE with both approaches,and both CPEs perform opposite variations as the moving platform upgrades.The findings provide theoretical reference for refinement of assembly quality evaluation of this mechanism. 展开更多
关键词 joint clearance docking mechanism probabilistic approach deterministic approach comprehensive pose error(CPE)
下载PDF
Complication rates after direct anterior vs posterior approach for hip hemiarthroplasty in elderly individuals with femoral neck fractures 被引量:3
7
作者 Tatiana Charles Nicolas Bloemers +1 位作者 Bilal Kapanci Marc Jayankura 《World Journal of Orthopedics》 2024年第1期22-29,共8页
BACKGROUND Dislocation rates after hemiarthroplasty reportedly vary from 1%to 17%.This serious complication is associated with increased morbidity and mortality rates.Approaches to this surgery are still debated,with ... BACKGROUND Dislocation rates after hemiarthroplasty reportedly vary from 1%to 17%.This serious complication is associated with increased morbidity and mortality rates.Approaches to this surgery are still debated,with no consensus regarding the superiority of any single approach.AIM To compare early postoperative complications after implementing the direct anterior and posterior approaches(PL)for hip hemiarthroplasty after femoral neck fractures.METHODS This is a comparative,retrospective,single-center cohort study conducted at a university hospital.Between March 2008 and December 2018,273 patients(a total of 280 hips)underwent bipolar hemiarthroplasties(n=280)for displaced femoral neck fractures using either the PL(n=171)or the minimally invasive direct anterior approach(DAA)(n=109).The choice of approach was related to the surgeons’practices;the implant types were similar and unrelated to the approach.Dislocation rates and other complications were reviewed after a minimum followup of 6 mo.RESULTS Both treatment groups had similarly aged patients(mean age:82 years),sex ratios,patient body mass indexes,and patient comorbidities.Surgical data(surgery delay time,operative time,and blood loss volume)did not differ significantly between the groups.The 30 d mortality rate was higher in the PL group(9.9%)than in the DAA group(3.7%),but the difference was not statistically significant(P=0.052).Among the one-month survivors,a significantly higher rate of dislocation was observed in the PL group(14/154;9.1%)than in the DAA group(0/105;0%)(P=0.002).Of the 14 patients with dislocation,8 underwent revision surgery for recurrent instability(posterior group),and one of them had 2 additional procedures due to a deep infection.The rate of other complications(e.g.,perioperative and early postoperative periprosthetic fractures and infection-related complications)did not differ significantly between the groups.CONCLUSION These findings suggest that the DAA to bipolar hemiarthroplasty for patients with femoral neck fractures is associated with a lower dislocation rate(<1%)than the PL. 展开更多
关键词 HEMIARTHROPLASTY Femoral neck fracture Direct anterior approach Posterior approach DISLOCATION MORTALITY
下载PDF
Improvement the Accuracy of Six Applied Classification Algorithms through Integrated Supervised and Unsupervised Learning Approach
8
作者 Sharareh R. Niakan Kalhori Xiao-Jun Zeng 《Journal of Computer and Communications》 2014年第4期201-209,共9页
We have presented an integrated approach based on supervised and unsupervised learning tech- nique to improve the accuracy of six predictive models. They are developed to predict outcome of tuberculosis treatment cour... We have presented an integrated approach based on supervised and unsupervised learning tech- nique to improve the accuracy of six predictive models. They are developed to predict outcome of tuberculosis treatment course and their accuracy needs to be improved as they are not precise as much as necessary. The integrated supervised and unsupervised learning method (ISULM) has been proposed as a new way to improve model accuracy. The dataset of 6450 Iranian TB patients under DOTS therapy was applied to initially select the significant predictors and then develop six predictive models using decision tree, Bayesian network, logistic regression, multilayer perceptron, radial basis function, and support vector machine algorithms. Developed models have integrated with k-mean clustering analysis to calculate more accurate predicted outcome of tuberculosis treatment course. Obtained results, then, have been evaluated to compare prediction accuracy before and after ISULM application. Recall, Precision, F-measure, and ROC area are other criteria used to assess the models validity as well as change percentage to show how different are models before and after ISULM. ISULM led to improve the prediction accuracy for all applied classifiers ranging between 4% and 10%. The most and least improvement for prediction accuracy were shown by logistic regression and support vector machine respectively. Pre-learning by k- mean clustering to relocate the objects and put similar cases in the same group can improve the classification accuracy in the process of integrating supervised and unsupervised learning. 展开更多
关键词 ISULM Integration Supervised and UNSUPERVISED Learning Classification accuracy TUBERCULOSIS
下载PDF
Quantifying the agreement and accuracy characteristics of four satellite-based LULC products for cropland classification in China 被引量:1
9
作者 Jie Xue Xianglin Zhang +3 位作者 Songchao Chen Bifeng Hu Nan Wang Zhou Shi 《Journal of Integrative Agriculture》 SCIE CSCD 2024年第1期283-297,共15页
Various land use and land cover(LULC)products have been produced over the past decade with the development of remote sensing technology.Despite the differences in LULC classification schemes,there is a lack of researc... Various land use and land cover(LULC)products have been produced over the past decade with the development of remote sensing technology.Despite the differences in LULC classification schemes,there is a lack of research on assessing the accuracy of their application to croplands in a unified framework.Thus,this study evaluated the spatial and area accuracies of cropland classification for four commonly used global LULC products(i.e.,MCD12Q1V6,GlobCover2009,FROM-GLC and GlobeLand30)based on the harmonised FAO criterion,and quantified the relationships between four factors(i.e.,slope,elevation,field size and crop system)and cropland classification agreement.The validation results indicated that MCD12Q1 and GlobeLand30 performed well in cropland classification regarding spatial consistency,with overall accuracies of 94.90 and 93.52%,respectively.The FROMGLC showed the worst performance,with an overall accuracy of 83.17%.Overlaying the cropland generated by the four global LULC products,we found the proportions of complete agreement and disagreement were 15.51 and 44.72% for the cropland classification,respectively.High consistency was mainly observed in the Northeast China Plain,the Huang-Huai-Hai Plain and the northern part of the Middle-lower Yangtze Plain,China.In contrast,low consistency was detected primarily on the eastern edge of the northern and semiarid region,the Yunnan-Guizhou Plateau and southern China.Field size was the most important factor for mapping cropland.For area accuracy,compared with China Statistical Yearbook data at the provincial scale,the accuracies of different products in descending order were:GlobeLand30,FROM-GLC,MCD12Q1,and GlobCover2009.The cropland classification schemes mainly caused large area deviations among the four products,and they also resulted in the different ranks of spatial accuracy and area accuracy among the four products.Our results can provide valuable suggestions for selecting cropland products at the national or provincial scale and help cropland mapping and reconstruction,which is essential for food security and crop management,so they can also contribute to achieving the Sustainable Development Goals issued by the United Nations. 展开更多
关键词 global LULC products cropland mapping accuracy evaluation food security China
下载PDF
A FLEXIBLE OBJECTIVE-CONSTRAINT APPROACH AND A NEW ALGORITHM FOR CONSTRUCTING THE PARETO FRONT OF MULTIOBJECTIVE OPTIMIZATION PROBLEMS 被引量:1
10
作者 N.HOSEINPOOR M.GHAZNAVI 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期702-720,共19页
In this article, a novel scalarization technique, called the improved objective-constraint approach, is introduced to find efficient solutions of a given multiobjective programming problem. The presented scalarized pr... In this article, a novel scalarization technique, called the improved objective-constraint approach, is introduced to find efficient solutions of a given multiobjective programming problem. The presented scalarized problem extends the objective-constraint problem. It is demonstrated that how adding variables to the scalarized problem, can lead to find conditions for (weakly, properly) Pareto optimal solutions. Applying the obtained necessary and sufficient conditions, two algorithms for generating the Pareto front approximation of bi-objective and three-objective programming problems are designed. These algorithms are easy to implement and can achieve an even approximation of (weakly, properly) Pareto optimal solutions. These algorithms can be generalized for optimization problems with more than three criterion functions, too. The effectiveness and capability of the algorithms are demonstrated in test problems. 展开更多
关键词 multiobjective optimization Pareto front SCALARIZATION objective-constraint approach proper efficient solution
下载PDF
Influence of initial check, information exchange, final accuracy check, reaction information nursing on the psychology of elderly with lung cancer 被引量:2
11
作者 Cui Jiang Jing Ma +1 位作者 Wen He Hai-Ying Zhang 《World Journal of Clinical Cases》 SCIE 2024年第4期737-745,共9页
BACKGROUND As one of the fatal diseases with high incidence,lung cancer has seriously endangered public health and safety.Elderly patients usually have poor self-care and are more likely to show a series of psychologi... BACKGROUND As one of the fatal diseases with high incidence,lung cancer has seriously endangered public health and safety.Elderly patients usually have poor self-care and are more likely to show a series of psychological problems.AIM To investigate the effectiveness of the initial check,information exchange,final accuracy check,reaction(IIFAR)information care model on the mental health status of elderly patients with lung cancer.METHODS This study is a single-centre study.We randomly recruited 60 elderly patients with lung cancer who attended our hospital from January 2021 to January 2022.These elderly patients with lung cancer were randomly divided into two groups,with the control group taking the conventional propaganda and education and the observation group taking the IIFAR information care model based on the conventional care protocol.The differences in psychological distress,anxiety and depression,life quality,fatigue,and the locus of control in psychology were compared between these two groups,and the causes of psychological distress were analyzed.RESULTS After the intervention,Distress Thermometer,Hospital Anxiety and Depression Scale(HADS)for anxiety and the HADS for depression,Revised Piper’s Fatigue Scale,and Chance Health Locus of Control scores were lower in the observation group compared to the pre-intervention period in the same group and were significantly lower in the observation group compared to those of the control group(P<0.05).After the intervention,Quality of Life Questionnaire Core 30(QLQ-C30),Internal Health Locus of Control,and Powerful Others Health Locus of Control scores were significantly higher in the observation and the control groups compared to the pre-intervention period in their same group,and QLQ-C30 scores were significantly higher in the observation group compared to those of the control group(P<0.05).CONCLUSION The IIFAR information care model can help elderly patients with lung cancer by reducing their anxiety and depression,psychological distress,and fatigue,improving their tendencies on the locus of control in psychology,and enhancing their life qualities. 展开更多
关键词 Initial check information exchange final accuracy check reaction information care model Lung cancer Mental health
下载PDF
Laparoscopic left hemihepatectomy guided by indocyanine green fluorescence: A cranial-dorsal approach 被引量:1
12
作者 Xing-Ru Wang Xiao-Ju Li +6 位作者 Dan-Dan Wan Qian Zhang Tian-Xi Liu Zong-Wen Shen Hong-Xing Tong Yan Li Jian-Wei Li 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期409-418,共10页
BACKGROUND Advancements in laparoscopic technology and a deeper understanding of intra-hepatic anatomy have led to the establishment of more precise laparoscopic hepatectomy(LH)techniques.The indocyanine green(ICG)flu... BACKGROUND Advancements in laparoscopic technology and a deeper understanding of intra-hepatic anatomy have led to the establishment of more precise laparoscopic hepatectomy(LH)techniques.The indocyanine green(ICG)fluorescence navi-gation technique has emerged as the most effective method for identifying hepatic regions,potentially overcoming the limitations of LH.While laparoscopic left hemihepatectomy(LLH)is a standardized procedure,there is a need for innova-tive strategies to enhance its outcomes.important anatomical markers,surgical skills,and ICG staining methods.METHODS Thirty-seven patients who underwent ICG fluorescence-guided LLH at Qujing Second People's Hospital between January 2019 and February 2022 were retrospectively analyzed.The cranial-dorsal approach was performed which involves dissecting the left hepatic vein cephalad,isolating the Arantius ligament,exposing the middle hepatic vein,and dissecting the parenchyma from the dorsal to the foot in order to complete the anatomical LLH.The surgical methods,as well as intra-and post-surgical data,were recorded and analyzed.Our hospital’s Medical Ethics Committee approved this study(Ethical review:2022-019-01).RESULTS Intraoperative blood loss during LLH was 335.68±99.869 mL and the rates of transfusion and conversion to laparotomy were 13.5%and 0%,respectively.The overall incidence of complications throughout the follow-up(median of 18 months;range 1-36 months)was 21.6%.No mortality or severe complications(level IV)were reported.CONCLUSION LLH has the potential to become a novel,standardized approach that can effectively,safely,and simply expose the middle hepatic vein and meet the requirements of precision surgery. 展开更多
关键词 Laparoscopic left hemihepatectomy Indocyanine green Cranial-dorsal approach Laparoscopic hepatectomy Arantius ligament Glissonean pedicle
下载PDF
Applying machine learning approaches to improving the accuracy of breast-tumour diagnosis via fine needle aspiration
13
作者 袁前飞 CAI Cong-zhong +1 位作者 XIAO Han-guang LIU Xing-hua 《Journal of Chongqing University》 CAS 2007年第1期1-7,共7页
Diagnosis and treatment of breast cancer have been improved during the last decade; however, breast cancer is still a leading cause of death among women in the whole world. Early detection and accurate diagnosis of th... Diagnosis and treatment of breast cancer have been improved during the last decade; however, breast cancer is still a leading cause of death among women in the whole world. Early detection and accurate diagnosis of this disease has been demonstrated an approach to long survival of the patients. As an attempt to develop a reliable diagnosing method for breast cancer, we integrated support vector machine (SVM), k-nearest neighbor and probabilistic neural network into a complex machine learning approach to detect malignant breast tumour through a set of indicators consisting of age and ten cellular features of fine-needle aspiration of breast which were ranked according to signal-to-noise ratio to identify determinants distinguishing benign breast tumours from malignant ones. The method turned out to significantly improve the diagnosis, with a sensitivity of 94.04%, a specificity of 97.37%, and an overall accuracy up to 96.24% when SVM was adopted with the sigmoid kernel function under 5-fold cross validation. The results suggest that SVM is a promising methodology to be further developed into a practical adjunct implement to help discerning benign and malignant breast tumours and thus reduce the incidence of misdiagnosis. 展开更多
关键词 breast cancer DIAGNOSIS machine learning approach fine needle aspirate feature ranking/filtering
下载PDF
Which approach of total hip arthroplasty is the best efficacy and least complication? 被引量:1
14
作者 Lertkong Nitiwarangkul Natthapong Hongku +3 位作者 Oraluck Pattanaprateep Sasivimol Rattanasiri Patarawan Woratanarat Ammarin Thakkinstian 《World Journal of Orthopedics》 2024年第1期73-93,共21页
BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications o... BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications of hip approaches remains inconclusive.This study conducted an umbrella review to systematically appraise previous meta-analysis(MAs)including conventional posterior approach(PA),and minimally invasive surgeries as the lateral approach(LA),direct anterior approach(DAA),2-incisions method,mini-lateral approach and the newest technique direct superior approach(DSA)or supercapsular percutaneouslyassisted total hip(SuperPath).AIM To compare the efficacy and complications of hip approaches that have been published in all MAs and randomized controlled trials(RCTs).METHODS MAs were identified from MEDLINE and Scopus from inception until 2023.RCTs were then updated from the latest MA to September 2023.This study included studies which compared hip approaches and reported at least one outcome such as Harris Hip Score(HHS),dislocation,intra-operative fracture,wound compliData were independently selected,extracted and assessed by two reviewers.Network MA and cluster rank and surface under the cumulative ranking curve(SUCRA)were estimated for treatment efficacy and safety.RESULTS Finally,twenty-eight MAs(40 RCTs),and 13 RCTs were retrieved.In total 47 RCTs were included for reanalysis.The results of corrected covered area showed high degree(13.80%).Among 47 RCTs,most of the studies were low risk of bias in part of random process and outcome reporting,while other domains were medium to high risk of bias.DAA significantly provided higher HHS at three months than PA[pooled unstandardized mean difference(USMD):3.49,95%confidence interval(CI):0.98,6.00 with SUCRA:85.9],followed by DSA/SuperPath(USMD:1.57,95%CI:-1.55,4.69 with SUCRA:57.6).All approaches had indifferent dislocation and intraoperative fracture rates.SUCRA comparing early functional outcome and composite complications(dislocation,intra-operative fracture,wound complication,and nerve injury)found DAA was the best approach followed by DSA/SuperPath.CONCLUSION DSA/SuperPath had better earlier functional outcome than PA,but still could not overcome the result of DAA.This technique might be the other preferred option with acceptable complications. 展开更多
关键词 Total hip arthroplasty Total hip replacement approach Supercapsular percutaneously-assisted total hip Harris Hip Score Intra-operative fracture
下载PDF
Minimalistic approach to left atrial appendage occlusion guided by cardiac computed tomography angiography
15
作者 Xian-Sai MENG Qing-Song WANG +7 位作者 Xin-Yan WANG Xu LU Yang MU Jing WANG Ting-Ting SONG Yun-Dai CHEN Tao CHEN Jun GUO 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期431-442,共12页
OBJECTIVE To assess the feasibility and safety of the minimalistic approach to left atrial appendage occlusion(LAAO) guided by cardiac computed tomography angiography(CCTA).METHODS Ninety consecutive patients who unde... OBJECTIVE To assess the feasibility and safety of the minimalistic approach to left atrial appendage occlusion(LAAO) guided by cardiac computed tomography angiography(CCTA).METHODS Ninety consecutive patients who underwent LAAO, with or without CCTA-guided, were matched(1:2). Each step of the LAAO procedure in the computed tomography(CT) guidance group(CT group) was directed by preprocedural CT planning. In the control group, LAAO was performed using the standard method. All patients were followed up for 12 months, and device surveillance was conducted using CCTA.RESULTS A total of 90 patients were included in the analysis, with 30 patients in the CT group and 60 matched patients in the control group. All patients were successfully implanted with Watchman devices. The mean ages for the CT group and the control group were 70.0 ± 9.4 years and 68.4 ± 11.9 years(P = 0.52), respectively. The procedure duration(45.6 ± 10.7 min vs. 58.8 ± 13.0 min,P < 0.001) and hospital stay(7.5 ± 2.4 day vs. 9.6 ± 2.8 day, P = 0.001) in the CT group was significantly shorter compared to the control group. However, the total radiation dose was higher in the CT group compared to the control group(904.9 ± 348.0 m Gy vs.711.9 ± 211.2 m Gy, P = 0.002). There were no significant differences in periprocedural pericardial effusion(3.3% vs. 6.3%, P = 0.8) between the two groups. The rate of postprocedural adverse events(13.3% vs. 18.3%, P = 0.55) were comparable between both groups at 12 months follow-up.CONCLUSIONS CCTA is capable of detailed LAAO procedure planning. Minimalistic LAAO with preprocedural CCTA planning was feasible and safe, with shortened procedure time and acceptable increased radiation and contras consumption. For patients with contraindications to general anesthesia and/or transesophageal echocardiography, this promising method may be an alternative to conventional LAAO. 展开更多
关键词 ANESTHESIA matched approach
下载PDF
Virtual source approach for maximizing resolution in high-penetration gamma-ray imaging
16
作者 Yuchi Wu Shaoyi Wang +14 位作者 Bin Zhu Yonghong Yan Minghai Yu Gang Li Xiaohui Zhang Yue Yang Fang Tan Feng Lu Bi Bi Xiaoqin Mao Zhonghai Wang Zongqing Zhao Jingqin Su Weimin Zhou Yuqiu Gu 《Matter and Radiation at Extremes》 SCIE EI CSCD 2024年第3期19-30,共12页
High-energy gamma-ray radiography has exceptional penetration ability and has become an indispensable nondestructive testing(NDT)tool in various fields.For high-energy photons,point projection radiography is almost th... High-energy gamma-ray radiography has exceptional penetration ability and has become an indispensable nondestructive testing(NDT)tool in various fields.For high-energy photons,point projection radiography is almost the only feasible imaging method,and its spatial resolution is primarily constrained by the size of the gamma-ray source.In conventional industrial applications,gamma-ray sources are commonly based on electron beams driven by accelerators,utilizing the process of bremsstrahlung radiation.The size of the gamma-ray source is dependent on the dimensional characteristics of the electron beam.Extensive research has been conducted on various advanced accelerator technologies that have the potential to greatly improve spatial resolution in NDT.In our investigation of laser-driven gamma-ray sources,a spatial resolution of about 90μm is achieved when the areal density of the penetrated object is 120 g/cm^(2).A virtual source approach is proposed to optimize the size of the gamma-ray source used for imaging,with the aim of maximizing spatial resolution.In this virtual source approach,the gamma ray can be considered as being emitted from a virtual source within the convertor,where the equivalent gamma-ray source size in imaging is much smaller than the actual emission area.On the basis of Monte Carlo simulations,we derive a set of evaluation formulas for virtual source scale and gamma-ray emission angle.Under optimal conditions,the virtual source size can be as small as 15μm,which can significantly improve the spatial resolution of high-penetration imaging to less than 50μm. 展开更多
关键词 RESOLUTION approach utilizing
下载PDF
Debate on direct-anterior vs posterior approach for hip hemiarthroplasty:The authors’insights
17
作者 Deepak Kumar Tarkik Thami Manjunath Nishani 《World Journal of Orthopedics》 2024年第5期486-488,共3页
We read and discussed the study entitled“Complication rates after direct anterior vs posterior approach for Hip Hemiarthroplasty in elderly individuals with femoral neck fractures”with great interest.The authors hav... We read and discussed the study entitled“Complication rates after direct anterior vs posterior approach for Hip Hemiarthroplasty in elderly individuals with femoral neck fractures”with great interest.The authors have done justice to the topic of comparison of anterior and posterior surgical approaches for bipolar hemiarthroplasty which has been an everlasting debate in the existing literature.However,there are certain aspects of this study that need clarification from the authors. 展开更多
关键词 COMMENTARY Direct anterior approach Posterior approach Hip hemiarthroplasty
下载PDF
Urea breath test for Helicobacter pylori infection in adult dyspeptic patients: A meta-analysis of diagnostic test accuracy
18
作者 Fabian Fellipe Bueno Lemos Caroline Tianeze de Castro +9 位作者 Marcel Silva Luz Gabriel Reis Rocha Gabriel Lima Correa Santos Luís Guilherme de Oliveira Silva Mariana Santos Calmon Cláudio Lima Souza Ana Carla Zarpelon-Schutz Kádima Nayara Teixeira Dulciene Maria de Magalhães Queiroz Fabrício Freire de Melo 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期579-598,共20页
BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for... BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice. 展开更多
关键词 Helicobacter pylori Urea breath test DIAGNOSIS Diagnostic test accuracy META-ANALYSIS
下载PDF
Direct anterior compared to posterior approach for hip hemiarthroplasty following femoral neck fractures
19
作者 Kevin A Wu Alexandra N Krez Albert T Anastasio 《World Journal of Orthopedics》 2024年第6期605-607,共3页
The differences in complication rates between the direct anterior and posterior approaches for hemiarthroplasty in elderly patients with femoral neck fractures are not yet fully understood.Dislocation,a severe complic... The differences in complication rates between the direct anterior and posterior approaches for hemiarthroplasty in elderly patients with femoral neck fractures are not yet fully understood.Dislocation,a severe complication associated with increased mortality and often requiring additional surgery,may occur less frequently with the direct anterior approach compared to the posterior approach.Careful consideration of patient demographics is essential when planning the surgical approach.Future research in this area should focus on robust randomized controlled trials involving elderly patients recovering from femoral neck fractures. 展开更多
关键词 Direct anterior approach Posterior approach HEMIARTHROPLASTY Femoral neck fractures ARTHROPLASTY DISLOCATION Surgical technique
下载PDF
Diagnostic Accuracy of Computerized Bowel Sound Analysis with Non-Invasive Devices for Irritable Bowel Syndrome:A Systematic Review and Meta-Analysis
20
作者 Xia-Xiao Yan Yue-Lun Zhang +2 位作者 Yu-Pei Zhang Ying-Yun Yang Dong Wu 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期122-130,共9页
Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,an... Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS. 展开更多
关键词 irritable bowel syndrome bowel sound analysis diagnostic accuracy systematic review META-ANALYSIS
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部