针对工业机械设备实时监测中不可控因素导致的振动信号数据缺失问题,提出一种基于自适应二次临近项交替方向乘子算法(adaptive quadratic proximity-alternating direction method of multipliers, AQ-ADMM)的压缩感知缺失信号重构方法...针对工业机械设备实时监测中不可控因素导致的振动信号数据缺失问题,提出一种基于自适应二次临近项交替方向乘子算法(adaptive quadratic proximity-alternating direction method of multipliers, AQ-ADMM)的压缩感知缺失信号重构方法。AQ-ADMM算法在经典交替方向乘子算法算法迭代过程中添加二次临近项,且能够自适应选取惩罚参数。首先在数据中心建立信号参考数据库用于构造初始字典,然后将K-奇异值分解(K-singular value decomposition, K-SVD)字典学习算法和AQ-ADMM算法结合重构缺失信号。对仿真信号和两种真实轴承信号数据集添加高斯白噪声后作为样本,试验结果表明当信号压缩率在50%~70%时,所提方法性能指标明显优于其它传统方法,在重构信号的同时实现了对含缺失数据机械振动信号的快速精确修复。展开更多
Anthraquinone-2-sulfonate(AQS) was employed in humus substitutes to evaluate the effects and influencing factors of U(VI) reduction by Shewanella oneidensis MR-1(S. oneidensis MR-1) under anaerobic condition. Th...Anthraquinone-2-sulfonate(AQS) was employed in humus substitutes to evaluate the effects and influencing factors of U(VI) reduction by Shewanella oneidensis MR-1(S. oneidensis MR-1) under anaerobic condition. The removal rate of U(VI) at 30 °C reaches 99.0% afterd 96 h with the p H value of 7.0 and AQS concentration of 1.0 mmol/L. The effective concentrations of AQS as the accelerator for U(VI) bioreduction are approximately 0.5-1.0 mmol/L. The bioreduction of U(VI) is inhibited when the concentration of AQS exceeds 2.0 mmol/L. The coexistence of ions, such as Cu2+, Cr6+, Mn2+, shows a remarkable negative effect on the U(VI) reduction, and Zn2+ shows less influence on the process compared with other tested ions. The U(VI) reduction is remarkably inhibited when the concentration of nitrate ion exceeds 1.0 mmol/L. Otherwise, no difference is found when the nitrate ion concentration is less than 0.5 mmol/L. Sulfate ion(5.0 mmol/L) slightly promotes the U(VI) reduction. Zero-valent iron(ZVI) promotes the U(VI) reduction by S. oneidensis, and the reduction rate improves with increasing the amount of ZVI in the range of 0-2.0 g/L. The XPS result indicates that uranium deposits on the cell surface are in U(VI) and U(IV) forms, and the majority of uranium in the solution is stable UO2.展开更多
文摘针对工业机械设备实时监测中不可控因素导致的振动信号数据缺失问题,提出一种基于自适应二次临近项交替方向乘子算法(adaptive quadratic proximity-alternating direction method of multipliers, AQ-ADMM)的压缩感知缺失信号重构方法。AQ-ADMM算法在经典交替方向乘子算法算法迭代过程中添加二次临近项,且能够自适应选取惩罚参数。首先在数据中心建立信号参考数据库用于构造初始字典,然后将K-奇异值分解(K-singular value decomposition, K-SVD)字典学习算法和AQ-ADMM算法结合重构缺失信号。对仿真信号和两种真实轴承信号数据集添加高斯白噪声后作为样本,试验结果表明当信号压缩率在50%~70%时,所提方法性能指标明显优于其它传统方法,在重构信号的同时实现了对含缺失数据机械振动信号的快速精确修复。
基金Projects(1117508111475080)supported by the National Natural Science Foundation of China+3 种基金project(13JJ3078)supported by the Natural Science Foundation of Hunan ProvinceChinaProject(14k083)supported by the Innovation Platform Open Fund Project of University in Hunan ProvinceChina
文摘Anthraquinone-2-sulfonate(AQS) was employed in humus substitutes to evaluate the effects and influencing factors of U(VI) reduction by Shewanella oneidensis MR-1(S. oneidensis MR-1) under anaerobic condition. The removal rate of U(VI) at 30 °C reaches 99.0% afterd 96 h with the p H value of 7.0 and AQS concentration of 1.0 mmol/L. The effective concentrations of AQS as the accelerator for U(VI) bioreduction are approximately 0.5-1.0 mmol/L. The bioreduction of U(VI) is inhibited when the concentration of AQS exceeds 2.0 mmol/L. The coexistence of ions, such as Cu2+, Cr6+, Mn2+, shows a remarkable negative effect on the U(VI) reduction, and Zn2+ shows less influence on the process compared with other tested ions. The U(VI) reduction is remarkably inhibited when the concentration of nitrate ion exceeds 1.0 mmol/L. Otherwise, no difference is found when the nitrate ion concentration is less than 0.5 mmol/L. Sulfate ion(5.0 mmol/L) slightly promotes the U(VI) reduction. Zero-valent iron(ZVI) promotes the U(VI) reduction by S. oneidensis, and the reduction rate improves with increasing the amount of ZVI in the range of 0-2.0 g/L. The XPS result indicates that uranium deposits on the cell surface are in U(VI) and U(IV) forms, and the majority of uranium in the solution is stable UO2.