An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoo...An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoor environment were measured at different control modes of DSF.The results show that the energy consumption of the air conditioning system in room B with opened exterior vents a closed interior facade and an air cavity with shading was 21.0% less than that in room A with closed exterior vents a closed interior facade and air cavity without shading in 9.5 h. The temperature distributions of the DSF and indoor environment in both horizontal and vertical directions were decisively influenced by shading conditions. The usage of shading devices strengthens the stack effect on the air cavity. Compared to room A the temperature distribution in room B is more uniform with smaller fluctuations.Meanwhile the problem of overheating in the air cavity of the DSF is still present in all tested conditions.展开更多
In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demon...In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demonstration system (ET 200). Commercial glass pane of 3 mm thick having the same dimensions as that of the apparatus was placed above the collector at a distance of 2 cm, 4 cm and 6 cm. Tests were done with and without the added glass. Experiments were performed for double glazing with two positions of the light meter. In one position, it was placed in the middle of the collector surface. While, in the other one, the light meter was placed in the middle of the added glass. To study the effect of double glazing on the performance of the solar collector ET 200, the correct position of the light meter was to place it exactly in the middle of the additional pane under the lamp. Double glazing does not enhance the performance of the solar collector because of the high resistance of the system glass air glass. The efficiency of double glazing solar collector decreases with the increasing the distance of the two separated glasses.展开更多
基金The National Natural Science Foundation of China(No.51308295,51206080)China Postdoctoral Science Foundation(No.2013M531368)
文摘An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoor environment were measured at different control modes of DSF.The results show that the energy consumption of the air conditioning system in room B with opened exterior vents a closed interior facade and an air cavity with shading was 21.0% less than that in room A with closed exterior vents a closed interior facade and air cavity without shading in 9.5 h. The temperature distributions of the DSF and indoor environment in both horizontal and vertical directions were decisively influenced by shading conditions. The usage of shading devices strengthens the stack effect on the air cavity. Compared to room A the temperature distribution in room B is more uniform with smaller fluctuations.Meanwhile the problem of overheating in the air cavity of the DSF is still present in all tested conditions.
文摘In this research paper, an attempt has been made to come across the effect of distance between double glazing on the efficiency of a solar thermal collector. Experiments were carded out on an active solar energy demonstration system (ET 200). Commercial glass pane of 3 mm thick having the same dimensions as that of the apparatus was placed above the collector at a distance of 2 cm, 4 cm and 6 cm. Tests were done with and without the added glass. Experiments were performed for double glazing with two positions of the light meter. In one position, it was placed in the middle of the collector surface. While, in the other one, the light meter was placed in the middle of the added glass. To study the effect of double glazing on the performance of the solar collector ET 200, the correct position of the light meter was to place it exactly in the middle of the additional pane under the lamp. Double glazing does not enhance the performance of the solar collector because of the high resistance of the system glass air glass. The efficiency of double glazing solar collector decreases with the increasing the distance of the two separated glasses.