A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph.In this paper,we show some necessary conditions that a 2-walk(a,b)-linear graph must obey.Using these conditions and some basic the...A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph.In this paper,we show some necessary conditions that a 2-walk(a,b)-linear graph must obey.Using these conditions and some basic theorems in graph theory,we characterize all 2-walk linear graphs with small cyclic graphs without pendants.The results are given in sort on unicyclic,bicyclic,tricyclic graphs.展开更多
A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph. In this paper, we show some structural properties that a 2-walk (a, b)-linear graph holds. According to these properties, we can e...A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph. In this paper, we show some structural properties that a 2-walk (a, b)-linear graph holds. According to these properties, we can estimate and characterize more 2-walk linear graphs that have exactly two main eigenvalues.展开更多
目的评价中文版行走受损问卷在2型糖尿病外周动脉疾病患者行走能力评估中的信效度。方法纳入2型糖尿病患者126例,据踝肱指数(Ankle-Brachial Index,ABI)分为PAD组(ABI<0.9,n=39)与非PAD组(ABI≥0.9,n=87),以中文版WIQ问卷、简明健康...目的评价中文版行走受损问卷在2型糖尿病外周动脉疾病患者行走能力评估中的信效度。方法纳入2型糖尿病患者126例,据踝肱指数(Ankle-Brachial Index,ABI)分为PAD组(ABI<0.9,n=39)与非PAD组(ABI≥0.9,n=87),以中文版WIQ问卷、简明健康调查问卷(SF-36)及6min步行试验(Six-minute walk test,6MWT)为研究工具行资料收集,采用信度分析、相关分析、两样本t检验等统计学方法评价量表信效度。结果WIQ量表总的Cronbach’sα系数为0.91,组内相关系数(Intraclass correlation reliability,ICC)为0.89。PAD组WIQ量表的距离、速度、爬梯维度评分及总评分与6min行走距离(Six-minute walk distance,6MWD)相关(r=0.76、0.84、0.60、0.86,均P<0.01)。PAD组WIQ各维度评分和总评分与SF-36生理功能(Physical Functioning,PF)、生理职能(Role-Physical,RP)维度评分相关(均P<0.01)。校正年龄后,PAD组与非PAD组间WIQ各维度评分及总评分的差异有显著意义(均P<0.01)。结论中文版行走受损问卷(WIQ)信效度较好,且简单、可靠、实用,可作为临床工具用于评估2型糖尿病外周动脉疾病患者的行走能力。展开更多
目的系统评价运动干预对2型糖尿病老年患者的步行功能的影响。方法计算机检索数据库PubMed、Web of Science、Cochrane Library、EMbase、CBM、中国知网、万方、维普,自建库至2019年7月1日,数据库中有关运动干预对2型糖尿病老年患者步...目的系统评价运动干预对2型糖尿病老年患者的步行功能的影响。方法计算机检索数据库PubMed、Web of Science、Cochrane Library、EMbase、CBM、中国知网、万方、维普,自建库至2019年7月1日,数据库中有关运动干预对2型糖尿病老年患者步行功能影响的随机对照试验,并追朔纳入研究的参考文献。按照纳入排除标准、提取资料并评价纳入研究的方法学质量后,采用RevMan5.3软件进行Meta分析。结果最终共纳入8篇文献,合计549例研究对象。Meta分析结果显示:运动能够减少2型糖尿病老年患者起立行走计时测试的时间,提高步行功能[MD=-1.63,95%CI(-1.83,-1.44),P<0.01];运动干预能够提高2型糖尿病老年患者6 min步行的长度,提高步行耐力和速度[MD=68.72,95%CI(39.98,97.45),P<0.01],运动干预能够提高2型糖尿病老年患者2 min原地踏步的步数,提高下肢活动能力[MD=23.34,95%CI(19.28,27.40),P<0.01],运动干预能够提高2型糖尿病老年患者30 s座椅站立的次数,提高下肢力量[MD=3.69,95%CI(2.84,4.55),P<0.01]。结论运动干预可以改善2型糖尿病老年患者的步行功能。展开更多
提出了一个刷新率达2GHz的10位电流驱动型数模转换器.在综合了精度与芯片面积等因素之后,该数模转换器使用6+4结构.采用电流型逻辑以提高转换器的速度,并采用Q2 random walk方法设计了一个双中心对称的电流矩阵,确保数模转换器的线性度...提出了一个刷新率达2GHz的10位电流驱动型数模转换器.在综合了精度与芯片面积等因素之后,该数模转换器使用6+4结构.采用电流型逻辑以提高转换器的速度,并采用Q2 random walk方法设计了一个双中心对称的电流矩阵,确保数模转换器的线性度.该数模转换器核心版图面积为2.2mm×2.2mm,在3.3V单电压供电的情况下,该芯片功耗为790mW.展开更多
基金Supported by the National Natural Science Foundation of China (10671081)
文摘A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph.In this paper,we show some necessary conditions that a 2-walk(a,b)-linear graph must obey.Using these conditions and some basic theorems in graph theory,we characterize all 2-walk linear graphs with small cyclic graphs without pendants.The results are given in sort on unicyclic,bicyclic,tricyclic graphs.
基金Supported by the National Natural Science Foundation of China(11171129)
文摘A graph has exactly two main eigenvalues if and only if it is a 2-walk linear graph. In this paper, we show some structural properties that a 2-walk (a, b)-linear graph holds. According to these properties, we can estimate and characterize more 2-walk linear graphs that have exactly two main eigenvalues.
文摘目的评价中文版行走受损问卷在2型糖尿病外周动脉疾病患者行走能力评估中的信效度。方法纳入2型糖尿病患者126例,据踝肱指数(Ankle-Brachial Index,ABI)分为PAD组(ABI<0.9,n=39)与非PAD组(ABI≥0.9,n=87),以中文版WIQ问卷、简明健康调查问卷(SF-36)及6min步行试验(Six-minute walk test,6MWT)为研究工具行资料收集,采用信度分析、相关分析、两样本t检验等统计学方法评价量表信效度。结果WIQ量表总的Cronbach’sα系数为0.91,组内相关系数(Intraclass correlation reliability,ICC)为0.89。PAD组WIQ量表的距离、速度、爬梯维度评分及总评分与6min行走距离(Six-minute walk distance,6MWD)相关(r=0.76、0.84、0.60、0.86,均P<0.01)。PAD组WIQ各维度评分和总评分与SF-36生理功能(Physical Functioning,PF)、生理职能(Role-Physical,RP)维度评分相关(均P<0.01)。校正年龄后,PAD组与非PAD组间WIQ各维度评分及总评分的差异有显著意义(均P<0.01)。结论中文版行走受损问卷(WIQ)信效度较好,且简单、可靠、实用,可作为临床工具用于评估2型糖尿病外周动脉疾病患者的行走能力。
文摘提出了一个刷新率达2GHz的10位电流驱动型数模转换器.在综合了精度与芯片面积等因素之后,该数模转换器使用6+4结构.采用电流型逻辑以提高转换器的速度,并采用Q2 random walk方法设计了一个双中心对称的电流矩阵,确保数模转换器的线性度.该数模转换器核心版图面积为2.2mm×2.2mm,在3.3V单电压供电的情况下,该芯片功耗为790mW.