Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabricat...Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.展开更多
A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which...A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.展开更多
文摘Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the drift problem.One is to tune the parameters of the fabrication process to improve the properties of the front-ended device.Another is to compensate the drift phenomenon by adding extra drift compensation circuit or software in the back-ended readout circuit.In this study,a drift calibration method for the potentiometric sensor was presented and the drift calibration method was performed by using the circuit.According to experimental results,the drift phenomenon of the SnO_2 pH electrode was reduced by the drift calibration device.
文摘A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.