期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Application of 2-D and 3-D Geo-electrical Resistivity Tomography and Geotechnical Soil Evaluation for Engineering Site Investigation:A Case Study of Okerenkoko Primary School,Warri-Southwest,Delta State,Nigeria
1
作者 U.Stanley Eze M.Edirin Okiotor +3 位作者 J.E.Ighodalo B.Jennifer Owonaro A.Saleh Saleh A.Sikiru Jamiu 《Advances in Geological and Geotechnical Engineering Research》 2023年第2期1-23,共23页
In the design of building structures,joint efforts must be decided to resolve the depth of competent layers across the intended site to safeguard the durability of civil engineering structures and to avert the disastr... In the design of building structures,joint efforts must be decided to resolve the depth of competent layers across the intended site to safeguard the durability of civil engineering structures and to avert the disastrous consequences of structural failure and collapse.In this study,an integrated methodology that employed DC resistivity tomography involving 2-D and 3-D techniques and geotechnical-soil analysis was used to evaluate subsoil conditions for engineering site investigation at Okerenkoko primary school,in the Warri-southwest area of Delta State,to adduce the phenomena responsible for the visible cracks/structural failure observed in the buildings.The results obtained brought to light the geological structure beneath the subsurface,which consists of four geoelectric layers identified as topsoil,dry/lithified upper sandy layer,wet sand(water-saturated)and peat/clay/sandy clayey soil(highly water-saturated).The deeply-seated peat/clay materials(ρ≤20Ωm)were delineated in the study area to the depths of 17.1 m and 19.8 m from 2-D and 3-D tomography respectively.3-D images presented as horizontal depth slices revealed the dominance of very low resistivity materials i.e.peat/clay/sandy clay within the fourth,fifth and sixth layers at depths ranging from 8.68-12.5 m,12.5-16.9 m and 16.9-21.9 m respectively.The dominance of mechanically unstable peat/clay/sandy clay layers beneath the subsurface,which are highly mobile in response to volumetric changes,is responsible for the noticeable cracks/failure detected on structures within the study site.These observations were validated by a geotechnical test of soil samples in the study area.Atterberg’s limits of the samples revealed plasticity indices of zero.Thus,the soil samples within the depth analyzed were representatives of sandy soil that does not possess any plasticity.The methods justifiably provided relevant information on the subsurface geology beneath the study site and should be appropriated as major tools for engineering site assessment/geotechnical projects. 展开更多
关键词 2d and 3d resistivity tomography Engineering site/structure Atterberg limits Orthogonal lines Radar sounding
下载PDF
Application of 3D Electrical Resistivity Tomography for Diagnosing Leakage in Earth Rock-Fill Dam
2
作者 Xin Zhang Mingjie Zhao +2 位作者 Kui Wang Pan Liu Huan Liu 《Engineering(科研)》 2016年第5期269-275,共7页
The leakage occurs during operation of the dam in Liuhuanggou reservoir. It’s a threat to the safety of the people’s lives and property in downstream. In order to eliminate the hidden danger of reservoir, ensure the... The leakage occurs during operation of the dam in Liuhuanggou reservoir. It’s a threat to the safety of the people’s lives and property in downstream. In order to eliminate the hidden danger of reservoir, ensure the safety of the dam, play better the function of flood control and water storage of the reservoir etc., we apply the 3D electrical resistivity tomography detecting technology and volume rendering image processing technology, make the measurement in field, process the data and combine the field survey to find out the leakage channels inside the dam. The results show that the 3D resistivity images appear the low resistivity zone corresponding with the leakage channels. There are two main leakage channels that come from different location inside the dam. It is feasible to diagnose the leakage in earth rock-fill dam by applying 3D electrical resistivity tomography. 展开更多
关键词 Earth Rock-Fill Dam LEAKAGE 3d electrical resistivity tomography Volume Rendering
下载PDF
Numerical Simulation Study on the Detection of Weak Structural Plane of Rock Slope by Using 3D Electrical Resistivity Tomography
3
作者 Xin Zhang 《Engineering(科研)》 2016年第7期438-444,共8页
The weak structure plane is an important factor affecting the stability of rock slope, and detecting the spatial structure of the weak structural plane is beneficial to analyze the stability of the slope and estimate ... The weak structure plane is an important factor affecting the stability of rock slope, and detecting the spatial structure of the weak structural plane is beneficial to analyze the stability of the slope and estimate the quantity of the landslide. Based on 3D electrical resistivity tomography, a model of rock slope with weak structure plane is established, and the characteristics of three-dimensional resistivity imaging of weak structure plane under different ground water conditions are simulated. The results show that the weak structural plane has a better reflection in 3D electrical resistivity tomography;the distribution of weak structural plane of 3D resistivity imaging can be roughly determined under different ground water conditions;the three-dimensional electrical resistivity tomography is feasible in the detection of weak structural plane of rock slope. 展开更多
关键词 Rock Slope Soft Structure Plane 3d electrical resistivity tomography Numerical Simulation
下载PDF
Integrated Geoelectrical Resistivity Method for Environmental Assessment of Landfill Leachate Pollution and Aquifer Vulnerability Studies
4
作者 Stanley U. Eze Omafume M. Orji +2 位作者 Abriku E. Onoriode Saleh A. Saleh Macpaul O. Abolarin 《Journal of Geoscience and Environment Protection》 2022年第9期1-26,共26页
Leachate plumes from landfills are a major source of pollution in Nigeria, especially in urban areas. Assessing leachate contamination in the subsoil is considered a complex process that needs detailed field measureme... Leachate plumes from landfills are a major source of pollution in Nigeria, especially in urban areas. Assessing leachate contamination in the subsoil is considered a complex process that needs detailed field measurement to accurately define the extent of contamination. To ascertain the extent of pollution of the subsoil and groundwater sources which were reportedly contaminated by leachate plumes from an old dumpsite located in Osubi town, an integrated geo-electrical method involving 1-D vertical electrical sounding (VES) and 2-D, 3-D ERT techniques were employed. Orthogonal set of 2-D apparent resistivity data was collected in a 100 × 50 m<sup>2</sup> rectangular grid around the dumpsite, using the Wenner array. Two years later, three (3) 2-D resistivity imaging profiles were also recorded in time-lapse mode at the dumpsite to monitor the possible effects of attenuation on the leachate over time. Ten (10) VES data were also acquired and used along with the 2-D imaging data. 2-D apparent resistivity data were inverted with Dipprowin software program. The orthogonal set of 2-D lines of apparent resistivity was merged into 3-D data and inverted with RES3DINV program to create a 3-D subsurface resistivity model. Geological models observed from 2-D and 3-D resistivity inversion revealed low resistivity values in the order ρ Ω·m which is indicative of leachate plumes in the saturation zone (pore water). The 2-D resistivity-depth sections imaged low resistivity leachate plumes at the near surface (<5 m) to a depth of 25.0 m, while 3-D inversion depth slices imaged leachate contaminant within the first, second and third layers at depth ranging from 0.00 - 2.50 m, 2.50 - 5.38 m and 5.38 - 8.68 m respectively. Thus, leachate contamination clearly increased with depth beyond the depth of first and second aquifers in the area which implies that available groundwater for domestic use is already contaminated with leachate from the dumpsite. Leachate contaminant-depth map estimated for the second geoelectric layers for VES 2, 3, 4, 7, 8, 9, and 10 shows that the second layer has been invaded completely by leachate contamination up to 6.5 m depth. 2-D apparent resistivity data acquired two years after show lower resistivity anomalies of the leachate plume caused by time-lapse attenuation effect on the observed resistivity of the leachate. This indicates that the leachate plume has become more conductive and toxic to the environment. The Longitudinal conductance map of the area shows that the aquifer protective capacity of this area is weak (0.1 - 0.19 Mho) thus, aquifers in the area are prone to pollution from the dumpsite. The three techniques used in this study (2-D, 3-D ERT and 1-D VES) fitly provided crucial information on the degree of contamination caused by the landfill leachate plume. Therefore, it is advisable to implement an environmental remediation and leachate management program. 展开更多
关键词 Leachate Contamination Groundwater Pollution 2d and 3d electrical resistivity tomography (ert) Aquifer Vulnerability Environmental Assessment
下载PDF
Detection technology and application of electromagnetic method for hidden danger of water gushing at coal face 被引量:2
5
作者 SHI Xian-xin YAN Shu +1 位作者 CHEN Ming-sheng FU Jun-mei 《Journal of Coal Science & Engineering(China)》 2009年第2期197-205,共9页
The principles,methods,technologies and application effects of several electromagneticmethods for the detection of the hidden danger of water gushing at the coalface were introduced.Also,emphasis was laid on expoundin... The principles,methods,technologies and application effects of several electromagneticmethods for the detection of the hidden danger of water gushing at the coalface were introduced.Also,emphasis was laid on expounding the methods,principles andeffects of down-hole detections by electric transmission tomography and transient electromagneticmethod.The potential of point power supplied in the underground homogeneoussemi-space,as well as the response to a low-resistivity abnormal body in file hemogeneoussemi-space,was simulated by adopting 3-D finite element method to interpretthe basic theory of the electric transmission tomography.The results of actual measurementshow that the mine electromagnetic method is sensitive to water-bearinglow-resistivity bodies and can play a unique role in detecting the hidden danger of watergushing at the coal face. 展开更多
关键词 采煤工作面 瞬变电磁法 检测技术 涌水 隐患 应用 三维有限元法 低电阻率
下载PDF
二维孔隙介质中重非水相液体饱和度测定与分析 被引量:7
6
作者 郭健 叶淑君 +2 位作者 肖安林 周启友 徐建平 《高校地质学报》 CAS CSCD 北大核心 2014年第2期324-332,共9页
在二维均质饱和孔隙介质中利用光透法与高密度电阻率法定量监测重非水相液体(DNAPL)的运移过程与饱和度。将光透法与高密度电阻率法相结合,进行高密度电阻率法对DNAPL在饱和多孔介质中渗流过程的定量监测。在二维砂箱中进行DNAPL的入渗... 在二维均质饱和孔隙介质中利用光透法与高密度电阻率法定量监测重非水相液体(DNAPL)的运移过程与饱和度。将光透法与高密度电阻率法相结合,进行高密度电阻率法对DNAPL在饱和多孔介质中渗流过程的定量监测。在二维砂箱中进行DNAPL的入渗试验,应用光透法与高密度电阻率法进行动态监测,分别利用CCD相机、LCR数字电桥采集数据。光透法的数据处理采用"水-DNAPL"两相中DNAPL饱和度的计算公式。而高密度电阻率法的数据处理是将获得的电阻值数据转化为电阻率值,然后利用Archie公式获得重非水相液体的饱和度空间分布。Archie公式中参数β值本文采用与光透法相结合的新方法来获取,克服了传统方法获取β值时存在的困难。根据不同时刻的饱和度空间分布可以估算注入砂箱内的DNAPL总量,并将其与实测的入渗量进行对比。结果表明,与光透法结合后的高密度电阻率成像法能定量监测饱和孔隙介质中DNAPL的入渗过程,且估算的DNAPL入渗量与实测值比较吻合,提出的基于光透法计算β值的新方法是有效且可行的。 展开更多
关键词 DNPAL 光透法 高密度电阻率法 孔隙介质 饱和度 二维
下载PDF