期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Dosimetric Comparison of Amorphous Silicon EPID and 2D Array Detector for Pre-Treatment Verification of Intensity Modulated Radiation Therapy 被引量:1
1
作者 Ayman G. Ibrahim Ismail E. Mohamed Hamdy M. Zidan 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期438-452,共15页
Purpose: To study the dosimetric characteristics of amorphous silicon Electronic Portal Imaging Device EPID and 2D array detector for dose verification of radiotherapy treatment plans, and the quality assurance QA tes... Purpose: To study the dosimetric characteristics of amorphous silicon Electronic Portal Imaging Device EPID and 2D array detector for dose verification of radiotherapy treatment plans, and the quality assurance QA testing of IMRT was investigated. Materials and methods: All measurements were done with Varian IX linear accelerator, aSi-1000 EPID and 2D array detector. The dose linearity, reproducibility, output factors, dose rate, SDD and response with slap phantom thickness have been measured and compared against those measured by ion chamber. Results: The characteristics of EPID and 2D array: the response of EPID agreed with 2D array and ion chamber 0.6cc. EPID and 2D array showed short-term output reproducibility with SD = 0.1%. The dose rates of 2D array SD = ±0.7%, EPID = ±0.4% compared with a 0.6 cc SD = ±0.5%. Output factor measurements for the central chamber of the EPID and 2D array showed no considerable deviation from ion chamber measurements. Measurement of beam profiles with the EPID and 2D array matched very well with the ion chamber measurements in the water phantom. The EPID is more sensitive to lower energy photons by increasing solid water phantom thickness. The mean and standard deviation passing rates (γ%≤1) for film, 2D array and EPID for 30 IMRT fields of five patients were 95.93 ± 0.96%, 99.05 ± 0.24%, and 99.37 ± 0.12%, respectively. Conclusion: The study shows that EPID and 2D array are a reliable and accurate dosimeter and a useful tool for quality assurance. We found that the EPID was more accurate compared with both 2D array and ion chamber. The gamma criterion of 3%/3 mm is the most suitable criteria for IMRT plans of QA. 展开更多
关键词 IMRT EPId 2d array detector GAMMA Index Quality ASSURANCE
下载PDF
Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning 被引量:2
2
作者 Meng-Ya Guo Xiu-Fang Li +6 位作者 Jie Wang Qi Liu Xiu-Zhen Deng Man-Zhou Zhang Li-Ren Shen Yue-Hu Pu Zhi-Ling Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期83-93,共11页
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are... The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%. 展开更多
关键词 2d ion chamber array detectors Laplacian pyramid image blending High-resolution reformatted methods Pencil beam scanning Proton therapy
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部