Objective:In our investigation,we studied the patients with medulloblastoma who received 3-dimensional conformal radiation therapy(3DCRT) and recorded their effects,side effects and failure reasons.Methods:From August...Objective:In our investigation,we studied the patients with medulloblastoma who received 3-dimensional conformal radiation therapy(3DCRT) and recorded their effects,side effects and failure reasons.Methods:From August 2001 to August 2007,34 children with medulloblastoma were treated in our hospital.The age at diagnosis was 3-16 years old,and the mean age at diagnosis was 9.5 years old.Among all the patients,16 cases were included in the high risk group and 18 cases were included in the low risk group.All the patients were performed total resection or subtotal resection and no patients received radiotherapy or chemotherapy before operation.All patients received 3DCRT within 3 weeks after resection.The dose of 30 Gy were given to the whole brain and whole spine,followed by 20-25 Gy boosted to the posterior brain fossa.The median fraction dose was 180 cGy.Every patient received the chemotherapy scheme of the Lomustine,Cisplatinum and Vincristine.Nobody received intrathecal chemotherapy.The tests of the complete blood count,blood biochemistry,hepatic and renal functions were required before every cycle of chemotherapy.Results:5-year overall survival(OS) and 5-year disease free survival(DFS) were 71% and 62% respectively.The median follow-up time was 36.5 months.The 5-year OS of the high risk group was 71% compared to 62% of the low risk group.There were significant difference between the two groups(P = 0.01).There were 13 failure cases in all the patients.Of these 13 patients,10 were dead and the other 3 were alive with tumor.The complete remission(CR) rate was 70.5% and the partial remission(PR) rate was 14%.Among the failure patients,there were 3 patients(8.8%) with the recurrences located in the brain of cribriform region.The 5-year OS of the patients with preoperative metastases was 12.5%(1/8),and which of the patients with residual tumor volume > 1.5 cm3 was 0%(0/5).Through the statistic analysis,it was found that both whether or not the metastases were found before surgery and residual tumor volume have the significant impacts on the prognosis of the children with medulloblastoma(P < 0.05).The major adverse reactions were hematological toxicity(7/34,20.6%) and gastrointestinal reaction(4/34,11.8%).Conclusion:Through the using of 3DCRT for the children with medulloblastoma,the severe side effects rate was not high.The prognosis of the patients in low risk group was satisfied which was opposite to that of the patients in high risk group.And the patients with residual tumor volume > 1.5 cm3 and preoperative metastases also had poor prognosis.It is needed to pay attention to the possible low dose of the brain of cribriform region.展开更多
Electromagnetic interference shielding(EMI SE)modules are the core com-ponent of modern electronics.However,the tra-ditional metal-based SE modules always take up indispensable three-dimensional space inside electroni...Electromagnetic interference shielding(EMI SE)modules are the core com-ponent of modern electronics.However,the tra-ditional metal-based SE modules always take up indispensable three-dimensional space inside electronics,posing a major obstacle to the integra-tion of electronics.The innovation of integrating 3D-printed conformal shielding(c-SE)modules with packaging materials onto core electronics offers infinite possibilities to satisfy ideal SE func-tion without occupying additional space.Herein,the 3D printable carbon-based inks with various proportions of graphene and carbon nanotube nanoparticles are well-formulated by manipulating their rheological peculiarity.Accordingly,the free-constructed architectures with arbitrarily-customized structure and multifunctionality are created via 3D printing.In particular,the SE performance of 3D-printed frame is up to 61.4 dB,simultaneously accompanied with an ultralight architecture of 0.076 g cm^(-3) and a superhigh specific shielding of 802.4 dB cm3 g^(-1).Moreover,as a proof-of-concept,the 3D-printed c-SE module is in situ integrated into core electronics,successfully replacing the traditional metal-based module to afford multiple functions for electromagnetic compatibility and thermal dissipa-tion.Thus,this scientific innovation completely makes up the blank for assembling carbon-based c-SE modules and sheds a brilliant light on developing the next generation of high-performance shielding materials with arbitrarily-customized structure for integrated electronics.展开更多
Background A growing number of studies worldwide have advocated the replacement of whole-breast irradiation with accelerated partial breast irradiation using three-dimensional conformal external-beam radiation (APBI-...Background A growing number of studies worldwide have advocated the replacement of whole-breast irradiation with accelerated partial breast irradiation using three-dimensional conformal external-beam radiation (APBI-3DCRr) for early-stage breast cancer. But APBI can be only used in selected population of patients with early-staged breast cancer. It is not replacing the whole breast radiotherapy. This study aimed to examine the feasibility and acute normal tissue toxicity of the APBI-3DCRT technique in Chinese female patients who generally have smaller breasts compared to their Western counterparts.Methods From May 2006 to December 2009, a total of 48 Chinese female patients (with early-stage breast cancer who met the inclusion criteria) received APBI-3DCRT after breast-conserving surgery at Sun Yat-sen University Cancer Center. The total dosage from APBI-3DCRT was 34 Gy, delivered in 3.4 Gy per fractions, twice per day at intervals of at least six hours. The radiation dose, volume of the target area and volume of irradiated normal tissues were calculated.Acute toxicity was evaluated according to the Common Toxicity Criteria (CTC) 3.0.Results Among the 48 patients, the planning target volume for evaluation (PTVE) was (90.42±9.26) cm3, the ipsilateral breast volume (IBV) was (421.74±28.53) cm3, and the ratio between the two was (20.74±5.86)%. Evaluation of the dosimetric characteristics of the PTVE revealed excellent dosimetric results in 14 patients and acceptable results in 34 patients. The dose delivered to the PTVE ranged from 93% to 110% of the prescribed dose. The average ratio of the volume of PTVE receiving 95% of the prescription dose (V95) was (99.26±0.37)%. The habituation index (HI) and the conformity index (CI) were 1.08±0.01 and 0.72±0.02, respectively, suggesting good homogeneity and conformity of the dose delivered to the target field. The radiation dose to normal tissues and organs was within the dose limitation.Subjects experienced mild acute toxicity. The main manifestations were breast edema in 22 patients, breast pain in 7,skin erythema in 25, general malaise in 22 and cytopenia in 8. No acute radiological cardiac or pulmonary injury was found.Conclusions The results of our short-term follow-up showed that it is feasible to perform APBI-3DCRT for early-stage breast cancer after breast-conserving surgery in Chinese female patients with smaller breasts. However, further studies are required to elucidate its efficacy and long-term side effects.展开更多
Objective: The aim of the study was to explore the efficacy of three-dimensional conformal radiotherapy (3D- CRT) combined with TP concurrent chemotherapy in treatment of recurrent cervical cancers. Methods: From ...Objective: The aim of the study was to explore the efficacy of three-dimensional conformal radiotherapy (3D- CRT) combined with TP concurrent chemotherapy in treatment of recurrent cervical cancers. Methods: From May 2005 to May 2009, 36 patients with recurrent cervical cancer were treated by 3D-CRT of 60-66 Gy and TP (docetaxel 70 mg/m^2, d1; cisplatin 20 mg/m^2, dl-d3; 21 days per cycle, totally 2 cycles) concurrent chemotherapy. Results: All of the patients had finished the 3D-CRT, the total response rate, complete response rate and partial response rate were 80.0% (28/35), 45.7% (16/35), and 34.3% (12/35), respectively. The pain-alleviation rate was 91.4% (32/35). The hemorrhage control rate was 94.3% (33/35). The median overall survival was 21.2 months. The 1-, 2- and 3-year survival rates were 54.3%, 37.1% and 22.8%, respectively. The life qualities of the patients were improved, without any treatment related death. Conclusion: Radiotherapy is effective and well-tolerated for recurrent cervical cancers, and it can promote regional control of the disease and prolong survival time.展开更多
The (3+1)-dimensional Jimbo-Miwa (JM) equation is solved approximately by using the conformal invariant asymptotic expansion approach presented by Ruan. By solving the new (3+1)-dimensional integrable models, ...The (3+1)-dimensional Jimbo-Miwa (JM) equation is solved approximately by using the conformal invariant asymptotic expansion approach presented by Ruan. By solving the new (3+1)-dimensional integrable models, which are conformal invariant and possess Painlevé property, the approximate solutions are obtained for the JM equation, containing not only one-soliton solutions but also periodic solutions and multi-soliton solutions. Some approximate solutions happen to be exact and some approximate solutions can become exact by choosing relations between the parameters properly.展开更多
Implantable hydrogel-based bioelectronics(IHB)can precisely monitor human health and diagnose diseases.However,achieving biodegradability,biocompatibility,and high conformality with soft tissues poses significant chal...Implantable hydrogel-based bioelectronics(IHB)can precisely monitor human health and diagnose diseases.However,achieving biodegradability,biocompatibility,and high conformality with soft tissues poses significant challenges for IHB.Gelatin is the most suitable candidate for IHB since it is a collagen hydrolysate and a substantial part of the extracellular matrix found naturally in most tissues.This study used 3D printing ultrafine fiber networks with metamaterial design to embed into ultra-low elastic modulus hydrogel to create a novel gelatin-based conductive film(GCF)with mechanical programmability.The regulation of GCF nearly covers soft tissue mechanics,an elastic modulus from 20 to 420 kPa,and a Poisson’s ratio from-0.25 to 0.52.The negative Poisson’s ratio promotes conformality with soft tissues to improve the efficiency of biological interfaces.The GCF can monitor heartbeat signals and respiratory rate by determining cardiac deformation due to its high conformability.Notably,the gelatin characteristics of the biodegradable GCF enable the sensor to monitor and support tissue restoration.The GCF metamaterial design offers a unique idea for bioelectronics to develop implantable sensors that integrate monitoring and tissue repair and a customized method for endowing implanted sensors to be highly conformal with soft tissues.展开更多
Objective:The aim of the study was to investigate the efficacy of three-dimensional conformal radiotherapy (3D-CRT) combined with Temozolomide (TMZ) concurrent chemotherapy in treatment of postoperative cerebral gliom...Objective:The aim of the study was to investigate the efficacy of three-dimensional conformal radiotherapy (3D-CRT) combined with Temozolomide (TMZ) concurrent chemotherapy in treatment of postoperative cerebral gliomas by prospective randomized controlled trials. Methods: Sixty-two patients with cerebral glioma who had residual tumor were divided into 3D-CRT group (radiotherapy group, n=31) and 3D-CRT with concurrent chemotherapy group (chemoradiotherapy group, n=31) prospectively. All patients received a dose of 50-60 Gy/25-30 F/5-6 weeks by 6 MV-X ray, three-dimensional conformal radiotherapy, 1 f/d, 5 times a week. Chemotherapy regimen was Temozolomide:75 mg/m2/d, concomitantly with radiotherapy, followed by 150-200 mg/m2/d, 5 days, 28 days per cycle, totally 3-6 cycles. Results: The total response rate was 35.3% (11/31) in radiotherapy group. The response rate was 61.3% (19/31) in chemoradiotherapy group. There was significant difference in curative effect (P=0.042). There was no significant difference in survival comparison of two groups (P=0.263). Stratified analysis showed the patients with grade Ⅲ gliomas of chemoradiotherapy group had better prognosis than ones of radiotherapy group (P=0.043). Conclusion: The 3D-CRT with concurrent chemotherapy can improve the survival of cerebral gliomas with pathological grade Ⅲ.展开更多
Lie symmetry analysis is applied to a(3+1)-dimensional Virasoro integrable model and the corresponding similarity reduction equations are obtained with the different infinitesimal generators.Invariant solutions with a...Lie symmetry analysis is applied to a(3+1)-dimensional Virasoro integrable model and the corresponding similarity reduction equations are obtained with the different infinitesimal generators.Invariant solutions with arbitrary functions for the(3+1)-dimensional Virasoro integrable model,including the interaction solution between a kink and a soliton,the lump-type solution and periodic solutions,have been studied analytically and graphically.展开更多
Based on the Hirota bilinear method,the second extended(3+1)-dimensional Jimbo–Miwa equation is established.By Maple symbolic calculation,lump and lump-kink soliton solutions are obtained.The interaction solutions be...Based on the Hirota bilinear method,the second extended(3+1)-dimensional Jimbo–Miwa equation is established.By Maple symbolic calculation,lump and lump-kink soliton solutions are obtained.The interaction solutions between the lump and multi-kink soliton,and the interaction between the lump and triangular periodic soliton are derived by combining a multi-exponential function or trigonometric sine and cosine functions with quadratic functions.Furthermore,periodiclump wave solution is derived via the ansatz including hyperbolic and trigonometric functions.Finally,3D plots,2D curves,density plots,and contour plots with particular choices of the suitable parameters are depicted to illustrate the dynamical features of these solutions.展开更多
Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional thr...Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy (3DCRT) in the radiotherapy of rectal cancer. Methods: Fifteen patients with rectal cancer treated with radio- therapy (RT) were retrospectively analyzed. Among the patients, seven received RT preoperatively and 8 postoperatively. The target volume and the OARs such as the small bowel, bladder and femoral heads were contoured for each patient. 3DCRT-plan and IMRT-plan were performed for each patient respectively, with the prescribed dose covering at least 95% of the planning target volume (PTV). The conformity index (CI) and homogeneity index (HI) were used for evaluation of the dose distribution in the target volume, and the Dx% (the lowest dose to the x% volume of the OARs that received the highest dose of irradiation) and the mean dose were used for evaluation of the dose to OARs. Paired-T test was used for companson of the difference between the two plans. Results: In the IMRT-plan and 3DCRT-plan, the CI were 0.94 and 0.87 (P = 0.000) and the HI were 1.13 and 1.17, respectively (P = 0.001). For small bowel, the D30%, D50% and the mean dose were 19.67 Gy, 15.13 Gy and 18.81 Gy in the IMRT-plan and 25.20 Gy, 22.20 Gy and 22.89 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For bladder, the D30%, D50%, and the mean dose were 24.80 Gy, 34.20 Gy and 28.70 Gy in the IMRT- plan, and 35.07 Gy, 44.67 Gy and 35.68 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For femoral heads, the D5% in the IMRT-plan and 3DCRT-plan were 40.6 Gy and 40.47 Gy, respectively (P = 0.936), and the mean dose were 30.14 Gy and 25.57 Gy, respectively (P = 0.001). Conclusion: Five-field IMRT-plan is better than 3DCRT-plan in the conformity and the dose homogeneity within target volume and also better in sparing the small bowel and bladder.展开更多
Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiothera...Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiotherapy (LCAFR) on patients with esophageal carcinoma. Methods: one hundred and one patients with esophageal carcinoma were divided into two groups. Observing group (49 cases) were treated by whole-course 3DCRT. Patients in control group (52 cases) were treated by conventional radiotherapy. Clinical efficiencies and radiation toxicities were compared between two groups. Results: The side effects including radiation esophagitis (63.2%) and tracheitis (49.0%) decreased in observing group, but there was no significant difference between two groups (69.2% and 55.7% in controls). The 1-, 2-and 3-year tumor local control rates and overall survival rates in the observing group were significantly improved compared with the control group, being respectively 87.8%, 75.5%, 63.3% vs 71.2%, 55.8%, 42.3% and 85.7%, 71.4%, 46.7% vs 69.2%, 51.9%, 26.9% (all P 0.05). Conclusion: The therapeutic effect of whole-course 3DCRT combined with LCAFR for esophageal carcinomas is superior to conventional radiotherapy.展开更多
Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor al...Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target.展开更多
Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patien...Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patients who had undergone previous external beam radiation therapy were retreated with 3-D CRT for locally recurrent NPC (33 poorly differentiated squamous cell carcinomas, 1 adenoma). The patients were re-staged according to Huaqing staging system with the following distribution: T1N0M0 in 5 cases, T2N0M0 in 11 cases, T3N0M0 in 12 cases, T4N0M0 in 6 cases. The maximal dimension of the gross tumor volume (GTV) ranged from 1.0 cm to 5.0 cm (median: 2.9 cm). CT simulation and 3-D planning were used to ensure full and conformal coverage of the planning target volume (PTV) by treated volume, while minimizing the absorbed dose of the adjacent normal tissue. 5–7 static conformal coplanar or noncoplanar portals were delivered for each fraction irradiation. The total dose delivered ranged from 65–70 Gy, with 2.5 Gy per fractionation, one fractionation per day, 5 days a week. Median follow-up time from 3-D CRT was 25 months (range: 12–36 months). Results: Over the follow-up period, local recurrence was observed in 3 patients, regional failure in 3, distant metastasis in 3, and six patients died; 88.2% (30/34) of the patient maintained local control, 82.4% (28/34) survived, and 76.5% (26/34) survived with no evidence of tumor. Acute complications were minor and few. The overall incidence of late complication was 20.6% (7/34), and severe complication was 14.7% (5/34), after re-irradiation with 3-D CRT. Conclusion: 3-D CRT is safety and effectiveness for most of the patients with locally recurrent NPC. Our preliminary results indicate a high local control rate and a low complication rate. The long-term curative effect and sequelae await further study.展开更多
Aims and background: we evaluate CT-3Tesla MRI fusion in conformal radiotherapy for localized prostate cancer.Methods: 18 consecutive patients underwent a 3T MRI scan under radiotherapy planning conditions, after the ...Aims and background: we evaluate CT-3Tesla MRI fusion in conformal radiotherapy for localized prostate cancer.Methods: 18 consecutive patients underwent a 3T MRI scan under radiotherapy planning conditions, after the CT scan. Bowel and bladder preparation were prescribed. CT and MR images were automatically fused;prostate and seminal vesicles were contoured on CT and on MRI, organs at risk were defined on CT-MRI fusion. Late rectal and sexual toxicity, differences in target volume between MRI and CT and differences in rectal and penile bulb dose distribution based on CT only or on CT-MRI fusion were evaluated.Results: one patient experienced a late rectal toxicity;no patient had sexual toxicity. The difference between the mean MRI and CT target volumes was statistically significant (p = 0.0001 paired Student's t-test). The dose-volume histogram (DVH) analysis shows a significant reduction of the dose received by the rectum and the penile bulb in MRI-plans compared to CT-plans.Conclusions: 3 Tesla MRI scan under radiotherapy planning conditions along with bowel preparation significantly improves the definition of the target volume sparing normal tissue irradiation.展开更多
For local radiotherapy, a three-dimensional(3D)conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single sour...For local radiotherapy, a three-dimensional(3D)conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single source is obtained using the Monte Carlo method, and the spatial dose maps are combined linearly to acquire the dose distribution. The dose distribution is visualized through the real-time display of the isodose line and isodose surface combined with the reconstructed 3D organ groups. By observing 3D dose coverage to the target volume and surrounding tissues, dose planning could be initiated with greater accuracy and precision to avoid dose dead zones and excessively high-dose levels, thus achieving the 3D conformal dose planning objective. Further research into the impact that blockages have on a needle trajectory can be conducted to optimize the insertion accuracy. A treatment planning system was developed to formulate and implement the 3D local treatment plan before the surgery,during the surgery, and after the surgery. Several experiments pertaining to both single-seed and multiple-seed dose distributions were conducted to verify the accuracy of the single-seed dose calculation module and 3D superposition dose calculation in the treatment planning system.展开更多
Objective: To determine the possible therapeutic gain of using three-dimensional conformal radiotherapy (3D-CRT) as a treatment option for portal vein tumor thrombus (PVTT) in patients with hepatocellular carcinoma (H...Objective: To determine the possible therapeutic gain of using three-dimensional conformal radiotherapy (3D-CRT) as a treatment option for portal vein tumor thrombus (PVTT) in patients with hepatocellular carcinoma (HCC) and to evaluate the tolerance and toxicity of using such treatment. Materials and methods: Sixty two patients were enrolled in this prospective study between June 2013 and August 2015. The clinical target volume (CTV) was the PVTT and the prescribed dose was 50 Gy/25 fractions. The median follow-up time was 7.4 months. Results: The thrombus crude response rate was 40.4% and the only significant prognostic factor for response was the thrombus size. Responders had significant better survival compared to non-responders with a median survival of 12.5 and 8 months respectively (P Conclusions: The results of this study suggest that radiotherapy should be considered as a safe treatment option for HCC patients with PVTT. It is effective not only for PVTT local control but also for survival, although prospective randomized trials are needed to confirm these results.展开更多
The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its ma...The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its main body is bestraddle in air,and has aerial intersections between its parts. This complex feature made cloverleaf junction quite different from buildings and terrain, therefore, it is difficult to express this kind of spatial objects in the same way as for buildings and terrain. In this paper,authors analyze spatial characteristics of cloverleaf junction, propose an all-constraint points TIN algorithm to partition cloverleaf junction road surface, and develop a method to visualize cloverleaf junction road surface using TIN. In order to manage cloverleaf junction data efficiently, the authors also analyzed the mechanism of 3DCM data management, extended BLOB type in relational database, and combined R-tree index to manage 3D spatial data. Based on this extension, an appropriate data展开更多
Using elementary integral method, a complete classification of all possible exact traveling wave solutions to (3+1)-dimensional Nizhnok-Novikov-Veselov equation is given. Some solutions are new.
Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-d...Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-dimensional potentiaial-YTSF equation. Baaed on the invariant group theory, Lie symmetries of the (3+1)-dimensional potential-YTSF equation are obtained. We equation with the given Lie symmetry.展开更多
This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A tota...This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A total of 41 male patients who presented with 2 of the following symptoms,i.e.,daytime sleepiness and fatigue,frequent snoring,and apnea with witness,were diagnosed as having OSAHS.They underwent full-night polysomnography and then dynamic 3-D CT imaging of the upper airway during quiet breathing and in Muller's maneuver.The soft palate length(SPL),the minimal cross-sectional area of the retropalatal region(mXSA-RP),and the vertical distance from the hard palate to the upper posterior part of the hyoid(hhL) were compared between the two breathing states.These parameters,together with hard palate length(HPL),were also compared between mild/moderate and severe OSAHS groups.Association of these parameters with the severity of OSAHS [as reflected by apnea hypopnea index(AHI) and the lowest saturation of blood oxygen(LSaO2)] was examined.The results showed that 31 patients had severe OSAHS,and 10 mild/moderate OSAHS.All the patients had airway obstruction at soft palate level.mXSA-RP was significantly decreased and SPL remarkably increased during Muller's maneuver as compared with the quiet breathing state.There were no significant differences in these airway parameters(except the position of the hyoid bone) between severe and mild/moderate OSAHS groups.And no significant correlation between these airway parameters and the severity of OSAHS was found.The position of hyoid was lower in the severe OSAHS group than in the mild/moderate OSAHS group.The patients in group with body mass index(BMI)≥26 had higher collapse ratio of mXSA-RP,greater neck circumference and smaller mXSA-RP in the Muller's maneuver than those in group with BMI26(P0.05 for all).It was concluded that dynamic 3-D CT imaging could dynamically show the upper airway changes at soft palate level in OSAHS patients.All the OSAHS patients had airway obstruction of various degrees at soft palate level.But no correlation was observed between the airway change at soft palate level and the severity of OSAHS.The patients in group with BMI≥26 were more likely to develop airway obstruction at soft palate level than those with BMI26.展开更多
文摘Objective:In our investigation,we studied the patients with medulloblastoma who received 3-dimensional conformal radiation therapy(3DCRT) and recorded their effects,side effects and failure reasons.Methods:From August 2001 to August 2007,34 children with medulloblastoma were treated in our hospital.The age at diagnosis was 3-16 years old,and the mean age at diagnosis was 9.5 years old.Among all the patients,16 cases were included in the high risk group and 18 cases were included in the low risk group.All the patients were performed total resection or subtotal resection and no patients received radiotherapy or chemotherapy before operation.All patients received 3DCRT within 3 weeks after resection.The dose of 30 Gy were given to the whole brain and whole spine,followed by 20-25 Gy boosted to the posterior brain fossa.The median fraction dose was 180 cGy.Every patient received the chemotherapy scheme of the Lomustine,Cisplatinum and Vincristine.Nobody received intrathecal chemotherapy.The tests of the complete blood count,blood biochemistry,hepatic and renal functions were required before every cycle of chemotherapy.Results:5-year overall survival(OS) and 5-year disease free survival(DFS) were 71% and 62% respectively.The median follow-up time was 36.5 months.The 5-year OS of the high risk group was 71% compared to 62% of the low risk group.There were significant difference between the two groups(P = 0.01).There were 13 failure cases in all the patients.Of these 13 patients,10 were dead and the other 3 were alive with tumor.The complete remission(CR) rate was 70.5% and the partial remission(PR) rate was 14%.Among the failure patients,there were 3 patients(8.8%) with the recurrences located in the brain of cribriform region.The 5-year OS of the patients with preoperative metastases was 12.5%(1/8),and which of the patients with residual tumor volume > 1.5 cm3 was 0%(0/5).Through the statistic analysis,it was found that both whether or not the metastases were found before surgery and residual tumor volume have the significant impacts on the prognosis of the children with medulloblastoma(P < 0.05).The major adverse reactions were hematological toxicity(7/34,20.6%) and gastrointestinal reaction(4/34,11.8%).Conclusion:Through the using of 3DCRT for the children with medulloblastoma,the severe side effects rate was not high.The prognosis of the patients in low risk group was satisfied which was opposite to that of the patients in high risk group.And the patients with residual tumor volume > 1.5 cm3 and preoperative metastases also had poor prognosis.It is needed to pay attention to the possible low dose of the brain of cribriform region.
基金This work is financially supported by the National Natural Science Foundation of China(52303036)the Natural Science Foundation of Guangxi Province(2020GXNSFAA297028)+4 种基金the Guangxi Science and Technology Base and Talent Special Project(GUIKE AD23026179)the International Science&Technology Cooperation Project of Chengdu(2021-GH03-00009-HZ)the Program of Innovative Research Team for Young Scientists of Sichuan Province(22CXTD0019)the Natural Science Foundation of Sichuan Province(2023NSFSC0986)the Opening Project of State Key Laboratory of Polymer Materials Engineering(Sichuan University)(Sklpme2023-3-18).
文摘Electromagnetic interference shielding(EMI SE)modules are the core com-ponent of modern electronics.However,the tra-ditional metal-based SE modules always take up indispensable three-dimensional space inside electronics,posing a major obstacle to the integra-tion of electronics.The innovation of integrating 3D-printed conformal shielding(c-SE)modules with packaging materials onto core electronics offers infinite possibilities to satisfy ideal SE func-tion without occupying additional space.Herein,the 3D printable carbon-based inks with various proportions of graphene and carbon nanotube nanoparticles are well-formulated by manipulating their rheological peculiarity.Accordingly,the free-constructed architectures with arbitrarily-customized structure and multifunctionality are created via 3D printing.In particular,the SE performance of 3D-printed frame is up to 61.4 dB,simultaneously accompanied with an ultralight architecture of 0.076 g cm^(-3) and a superhigh specific shielding of 802.4 dB cm3 g^(-1).Moreover,as a proof-of-concept,the 3D-printed c-SE module is in situ integrated into core electronics,successfully replacing the traditional metal-based module to afford multiple functions for electromagnetic compatibility and thermal dissipa-tion.Thus,this scientific innovation completely makes up the blank for assembling carbon-based c-SE modules and sheds a brilliant light on developing the next generation of high-performance shielding materials with arbitrarily-customized structure for integrated electronics.
文摘Background A growing number of studies worldwide have advocated the replacement of whole-breast irradiation with accelerated partial breast irradiation using three-dimensional conformal external-beam radiation (APBI-3DCRr) for early-stage breast cancer. But APBI can be only used in selected population of patients with early-staged breast cancer. It is not replacing the whole breast radiotherapy. This study aimed to examine the feasibility and acute normal tissue toxicity of the APBI-3DCRT technique in Chinese female patients who generally have smaller breasts compared to their Western counterparts.Methods From May 2006 to December 2009, a total of 48 Chinese female patients (with early-stage breast cancer who met the inclusion criteria) received APBI-3DCRT after breast-conserving surgery at Sun Yat-sen University Cancer Center. The total dosage from APBI-3DCRT was 34 Gy, delivered in 3.4 Gy per fractions, twice per day at intervals of at least six hours. The radiation dose, volume of the target area and volume of irradiated normal tissues were calculated.Acute toxicity was evaluated according to the Common Toxicity Criteria (CTC) 3.0.Results Among the 48 patients, the planning target volume for evaluation (PTVE) was (90.42±9.26) cm3, the ipsilateral breast volume (IBV) was (421.74±28.53) cm3, and the ratio between the two was (20.74±5.86)%. Evaluation of the dosimetric characteristics of the PTVE revealed excellent dosimetric results in 14 patients and acceptable results in 34 patients. The dose delivered to the PTVE ranged from 93% to 110% of the prescribed dose. The average ratio of the volume of PTVE receiving 95% of the prescription dose (V95) was (99.26±0.37)%. The habituation index (HI) and the conformity index (CI) were 1.08±0.01 and 0.72±0.02, respectively, suggesting good homogeneity and conformity of the dose delivered to the target field. The radiation dose to normal tissues and organs was within the dose limitation.Subjects experienced mild acute toxicity. The main manifestations were breast edema in 22 patients, breast pain in 7,skin erythema in 25, general malaise in 22 and cytopenia in 8. No acute radiological cardiac or pulmonary injury was found.Conclusions The results of our short-term follow-up showed that it is feasible to perform APBI-3DCRT for early-stage breast cancer after breast-conserving surgery in Chinese female patients with smaller breasts. However, further studies are required to elucidate its efficacy and long-term side effects.
文摘Objective: The aim of the study was to explore the efficacy of three-dimensional conformal radiotherapy (3D- CRT) combined with TP concurrent chemotherapy in treatment of recurrent cervical cancers. Methods: From May 2005 to May 2009, 36 patients with recurrent cervical cancer were treated by 3D-CRT of 60-66 Gy and TP (docetaxel 70 mg/m^2, d1; cisplatin 20 mg/m^2, dl-d3; 21 days per cycle, totally 2 cycles) concurrent chemotherapy. Results: All of the patients had finished the 3D-CRT, the total response rate, complete response rate and partial response rate were 80.0% (28/35), 45.7% (16/35), and 34.3% (12/35), respectively. The pain-alleviation rate was 91.4% (32/35). The hemorrhage control rate was 94.3% (33/35). The median overall survival was 21.2 months. The 1-, 2- and 3-year survival rates were 54.3%, 37.1% and 22.8%, respectively. The life qualities of the patients were improved, without any treatment related death. Conclusion: Radiotherapy is effective and well-tolerated for recurrent cervical cancers, and it can promote regional control of the disease and prolong survival time.
基金The project supported by the Natural Science Foundation of Zhejiang Province of China under Grant No. Y604036 and State Key Laboratory of 0il/Gas Reservoir Geology and Exploitation "PLN0402" The authors would like to thank Prof. Sen-Yue Lou for his help and discussion.
文摘The (3+1)-dimensional Jimbo-Miwa (JM) equation is solved approximately by using the conformal invariant asymptotic expansion approach presented by Ruan. By solving the new (3+1)-dimensional integrable models, which are conformal invariant and possess Painlevé property, the approximate solutions are obtained for the JM equation, containing not only one-soliton solutions but also periodic solutions and multi-soliton solutions. Some approximate solutions happen to be exact and some approximate solutions can become exact by choosing relations between the parameters properly.
基金This work was sponsored by the National Natural Science Foundation of China(No.52235007,52325504)the Science Fund for Creative Research Groups of the National Natural Science Foundation of China(No.T2121004).
文摘Implantable hydrogel-based bioelectronics(IHB)can precisely monitor human health and diagnose diseases.However,achieving biodegradability,biocompatibility,and high conformality with soft tissues poses significant challenges for IHB.Gelatin is the most suitable candidate for IHB since it is a collagen hydrolysate and a substantial part of the extracellular matrix found naturally in most tissues.This study used 3D printing ultrafine fiber networks with metamaterial design to embed into ultra-low elastic modulus hydrogel to create a novel gelatin-based conductive film(GCF)with mechanical programmability.The regulation of GCF nearly covers soft tissue mechanics,an elastic modulus from 20 to 420 kPa,and a Poisson’s ratio from-0.25 to 0.52.The negative Poisson’s ratio promotes conformality with soft tissues to improve the efficiency of biological interfaces.The GCF can monitor heartbeat signals and respiratory rate by determining cardiac deformation due to its high conformability.Notably,the gelatin characteristics of the biodegradable GCF enable the sensor to monitor and support tissue restoration.The GCF metamaterial design offers a unique idea for bioelectronics to develop implantable sensors that integrate monitoring and tissue repair and a customized method for endowing implanted sensors to be highly conformal with soft tissues.
文摘Objective:The aim of the study was to investigate the efficacy of three-dimensional conformal radiotherapy (3D-CRT) combined with Temozolomide (TMZ) concurrent chemotherapy in treatment of postoperative cerebral gliomas by prospective randomized controlled trials. Methods: Sixty-two patients with cerebral glioma who had residual tumor were divided into 3D-CRT group (radiotherapy group, n=31) and 3D-CRT with concurrent chemotherapy group (chemoradiotherapy group, n=31) prospectively. All patients received a dose of 50-60 Gy/25-30 F/5-6 weeks by 6 MV-X ray, three-dimensional conformal radiotherapy, 1 f/d, 5 times a week. Chemotherapy regimen was Temozolomide:75 mg/m2/d, concomitantly with radiotherapy, followed by 150-200 mg/m2/d, 5 days, 28 days per cycle, totally 3-6 cycles. Results: The total response rate was 35.3% (11/31) in radiotherapy group. The response rate was 61.3% (19/31) in chemoradiotherapy group. There was significant difference in curative effect (P=0.042). There was no significant difference in survival comparison of two groups (P=0.263). Stratified analysis showed the patients with grade Ⅲ gliomas of chemoradiotherapy group had better prognosis than ones of radiotherapy group (P=0.043). Conclusion: The 3D-CRT with concurrent chemotherapy can improve the survival of cerebral gliomas with pathological grade Ⅲ.
文摘Lie symmetry analysis is applied to a(3+1)-dimensional Virasoro integrable model and the corresponding similarity reduction equations are obtained with the different infinitesimal generators.Invariant solutions with arbitrary functions for the(3+1)-dimensional Virasoro integrable model,including the interaction solution between a kink and a soliton,the lump-type solution and periodic solutions,have been studied analytically and graphically.
文摘Based on the Hirota bilinear method,the second extended(3+1)-dimensional Jimbo–Miwa equation is established.By Maple symbolic calculation,lump and lump-kink soliton solutions are obtained.The interaction solutions between the lump and multi-kink soliton,and the interaction between the lump and triangular periodic soliton are derived by combining a multi-exponential function or trigonometric sine and cosine functions with quadratic functions.Furthermore,periodiclump wave solution is derived via the ansatz including hyperbolic and trigonometric functions.Finally,3D plots,2D curves,density plots,and contour plots with particular choices of the suitable parameters are depicted to illustrate the dynamical features of these solutions.
文摘Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy (3DCRT) in the radiotherapy of rectal cancer. Methods: Fifteen patients with rectal cancer treated with radio- therapy (RT) were retrospectively analyzed. Among the patients, seven received RT preoperatively and 8 postoperatively. The target volume and the OARs such as the small bowel, bladder and femoral heads were contoured for each patient. 3DCRT-plan and IMRT-plan were performed for each patient respectively, with the prescribed dose covering at least 95% of the planning target volume (PTV). The conformity index (CI) and homogeneity index (HI) were used for evaluation of the dose distribution in the target volume, and the Dx% (the lowest dose to the x% volume of the OARs that received the highest dose of irradiation) and the mean dose were used for evaluation of the dose to OARs. Paired-T test was used for companson of the difference between the two plans. Results: In the IMRT-plan and 3DCRT-plan, the CI were 0.94 and 0.87 (P = 0.000) and the HI were 1.13 and 1.17, respectively (P = 0.001). For small bowel, the D30%, D50% and the mean dose were 19.67 Gy, 15.13 Gy and 18.81 Gy in the IMRT-plan and 25.20 Gy, 22.20 Gy and 22.89 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For bladder, the D30%, D50%, and the mean dose were 24.80 Gy, 34.20 Gy and 28.70 Gy in the IMRT- plan, and 35.07 Gy, 44.67 Gy and 35.68 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For femoral heads, the D5% in the IMRT-plan and 3DCRT-plan were 40.6 Gy and 40.47 Gy, respectively (P = 0.936), and the mean dose were 30.14 Gy and 25.57 Gy, respectively (P = 0.001). Conclusion: Five-field IMRT-plan is better than 3DCRT-plan in the conformity and the dose homogeneity within target volume and also better in sparing the small bowel and bladder.
文摘Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiotherapy (LCAFR) on patients with esophageal carcinoma. Methods: one hundred and one patients with esophageal carcinoma were divided into two groups. Observing group (49 cases) were treated by whole-course 3DCRT. Patients in control group (52 cases) were treated by conventional radiotherapy. Clinical efficiencies and radiation toxicities were compared between two groups. Results: The side effects including radiation esophagitis (63.2%) and tracheitis (49.0%) decreased in observing group, but there was no significant difference between two groups (69.2% and 55.7% in controls). The 1-, 2-and 3-year tumor local control rates and overall survival rates in the observing group were significantly improved compared with the control group, being respectively 87.8%, 75.5%, 63.3% vs 71.2%, 55.8%, 42.3% and 85.7%, 71.4%, 46.7% vs 69.2%, 51.9%, 26.9% (all P 0.05). Conclusion: The therapeutic effect of whole-course 3DCRT combined with LCAFR for esophageal carcinomas is superior to conventional radiotherapy.
基金Grant sponsor:Guangzhou Municipal Medicin &Health ProgramGrant number:2006-YB-177
文摘Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target.
文摘Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patients who had undergone previous external beam radiation therapy were retreated with 3-D CRT for locally recurrent NPC (33 poorly differentiated squamous cell carcinomas, 1 adenoma). The patients were re-staged according to Huaqing staging system with the following distribution: T1N0M0 in 5 cases, T2N0M0 in 11 cases, T3N0M0 in 12 cases, T4N0M0 in 6 cases. The maximal dimension of the gross tumor volume (GTV) ranged from 1.0 cm to 5.0 cm (median: 2.9 cm). CT simulation and 3-D planning were used to ensure full and conformal coverage of the planning target volume (PTV) by treated volume, while minimizing the absorbed dose of the adjacent normal tissue. 5–7 static conformal coplanar or noncoplanar portals were delivered for each fraction irradiation. The total dose delivered ranged from 65–70 Gy, with 2.5 Gy per fractionation, one fractionation per day, 5 days a week. Median follow-up time from 3-D CRT was 25 months (range: 12–36 months). Results: Over the follow-up period, local recurrence was observed in 3 patients, regional failure in 3, distant metastasis in 3, and six patients died; 88.2% (30/34) of the patient maintained local control, 82.4% (28/34) survived, and 76.5% (26/34) survived with no evidence of tumor. Acute complications were minor and few. The overall incidence of late complication was 20.6% (7/34), and severe complication was 14.7% (5/34), after re-irradiation with 3-D CRT. Conclusion: 3-D CRT is safety and effectiveness for most of the patients with locally recurrent NPC. Our preliminary results indicate a high local control rate and a low complication rate. The long-term curative effect and sequelae await further study.
文摘Aims and background: we evaluate CT-3Tesla MRI fusion in conformal radiotherapy for localized prostate cancer.Methods: 18 consecutive patients underwent a 3T MRI scan under radiotherapy planning conditions, after the CT scan. Bowel and bladder preparation were prescribed. CT and MR images were automatically fused;prostate and seminal vesicles were contoured on CT and on MRI, organs at risk were defined on CT-MRI fusion. Late rectal and sexual toxicity, differences in target volume between MRI and CT and differences in rectal and penile bulb dose distribution based on CT only or on CT-MRI fusion were evaluated.Results: one patient experienced a late rectal toxicity;no patient had sexual toxicity. The difference between the mean MRI and CT target volumes was statistically significant (p = 0.0001 paired Student's t-test). The dose-volume histogram (DVH) analysis shows a significant reduction of the dose received by the rectum and the penile bulb in MRI-plans compared to CT-plans.Conclusions: 3 Tesla MRI scan under radiotherapy planning conditions along with bowel preparation significantly improves the definition of the target volume sparing normal tissue irradiation.
基金supported by the National Natural Science Foundation of China(no.51175373)the Key Technology and Development Program of the Tianjin Municipal Science and Technology Commission(no.14ZCDZGX00490)
文摘For local radiotherapy, a three-dimensional(3D)conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single source is obtained using the Monte Carlo method, and the spatial dose maps are combined linearly to acquire the dose distribution. The dose distribution is visualized through the real-time display of the isodose line and isodose surface combined with the reconstructed 3D organ groups. By observing 3D dose coverage to the target volume and surrounding tissues, dose planning could be initiated with greater accuracy and precision to avoid dose dead zones and excessively high-dose levels, thus achieving the 3D conformal dose planning objective. Further research into the impact that blockages have on a needle trajectory can be conducted to optimize the insertion accuracy. A treatment planning system was developed to formulate and implement the 3D local treatment plan before the surgery,during the surgery, and after the surgery. Several experiments pertaining to both single-seed and multiple-seed dose distributions were conducted to verify the accuracy of the single-seed dose calculation module and 3D superposition dose calculation in the treatment planning system.
文摘Objective: To determine the possible therapeutic gain of using three-dimensional conformal radiotherapy (3D-CRT) as a treatment option for portal vein tumor thrombus (PVTT) in patients with hepatocellular carcinoma (HCC) and to evaluate the tolerance and toxicity of using such treatment. Materials and methods: Sixty two patients were enrolled in this prospective study between June 2013 and August 2015. The clinical target volume (CTV) was the PVTT and the prescribed dose was 50 Gy/25 fractions. The median follow-up time was 7.4 months. Results: The thrombus crude response rate was 40.4% and the only significant prognostic factor for response was the thrombus size. Responders had significant better survival compared to non-responders with a median survival of 12.5 and 8 months respectively (P Conclusions: The results of this study suggest that radiotherapy should be considered as a safe treatment option for HCC patients with PVTT. It is effective not only for PVTT local control but also for survival, although prospective randomized trials are needed to confirm these results.
文摘The research work has been seldom done about cloverleaf junction expression in a 3-dimensional city model (3DCM). The main reason is that the cloverleaf junction is often in a complex and enormous construction. Its main body is bestraddle in air,and has aerial intersections between its parts. This complex feature made cloverleaf junction quite different from buildings and terrain, therefore, it is difficult to express this kind of spatial objects in the same way as for buildings and terrain. In this paper,authors analyze spatial characteristics of cloverleaf junction, propose an all-constraint points TIN algorithm to partition cloverleaf junction road surface, and develop a method to visualize cloverleaf junction road surface using TIN. In order to manage cloverleaf junction data efficiently, the authors also analyzed the mechanism of 3DCM data management, extended BLOB type in relational database, and combined R-tree index to manage 3D spatial data. Based on this extension, an appropriate data
基金The project supported by Scientific Research Fund of Heilongjiang Province of China under Grant No. 11511008The author would like to thank referees for their valuable suggestions.
文摘Using elementary integral method, a complete classification of all possible exact traveling wave solutions to (3+1)-dimensional Nizhnok-Novikov-Veselov equation is given. Some solutions are new.
基金The project supported by the Natural Science Foundation of Shandong Province of China under Grant No. 2004zx16 tCorresponding author, E-maih zzlh100@163.com
文摘Using the modified find some new exact solutions to Lie point symmetry groups and also get conservation laws, of the CK's direct method, we build the relationship between new solutions and old ones and the (3+1)-dimensional potentiaial-YTSF equation. Baaed on the invariant group theory, Lie symmetries of the (3+1)-dimensional potential-YTSF equation are obtained. We equation with the given Lie symmetry.
文摘This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A total of 41 male patients who presented with 2 of the following symptoms,i.e.,daytime sleepiness and fatigue,frequent snoring,and apnea with witness,were diagnosed as having OSAHS.They underwent full-night polysomnography and then dynamic 3-D CT imaging of the upper airway during quiet breathing and in Muller's maneuver.The soft palate length(SPL),the minimal cross-sectional area of the retropalatal region(mXSA-RP),and the vertical distance from the hard palate to the upper posterior part of the hyoid(hhL) were compared between the two breathing states.These parameters,together with hard palate length(HPL),were also compared between mild/moderate and severe OSAHS groups.Association of these parameters with the severity of OSAHS [as reflected by apnea hypopnea index(AHI) and the lowest saturation of blood oxygen(LSaO2)] was examined.The results showed that 31 patients had severe OSAHS,and 10 mild/moderate OSAHS.All the patients had airway obstruction at soft palate level.mXSA-RP was significantly decreased and SPL remarkably increased during Muller's maneuver as compared with the quiet breathing state.There were no significant differences in these airway parameters(except the position of the hyoid bone) between severe and mild/moderate OSAHS groups.And no significant correlation between these airway parameters and the severity of OSAHS was found.The position of hyoid was lower in the severe OSAHS group than in the mild/moderate OSAHS group.The patients in group with body mass index(BMI)≥26 had higher collapse ratio of mXSA-RP,greater neck circumference and smaller mXSA-RP in the Muller's maneuver than those in group with BMI26(P0.05 for all).It was concluded that dynamic 3-D CT imaging could dynamically show the upper airway changes at soft palate level in OSAHS patients.All the OSAHS patients had airway obstruction of various degrees at soft palate level.But no correlation was observed between the airway change at soft palate level and the severity of OSAHS.The patients in group with BMI≥26 were more likely to develop airway obstruction at soft palate level than those with BMI26.