Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the tec...Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the technical quality of the obtained tomography using 3.0 T and 1.5 T MRI, and to compare the subjective feeling of discomfort of patients and subjective acoustic noise experience during imaging using MRI at 3.0 T and 1.5 T. Brain MRI (1.5 and 3.0 T) was performed in 58 patients, according to a standardized protocol. All studies have been randomly described by independent two radiologists. The reference standard for the existence of technical artifact is established on the basis of both radiologists’ consensus. We also compared the subjective feelings of the discomfort and acoustic noise during the both MRI (1.5 T and 3.0 T) exams. Artifacts were significantly more common during 3.0 T MRI in comparison with the 1.5 T MRI (χ2 = 5.286, P < 0.05), as well as in male patients (χ2 = 8.841, P < 0.05), and sub-jective assessments of discomfort and acoustic noise were higher in patients who underwent imaging using 3.0 T MRI, (χ2 = 125.959, df = 1, P < 0.001) and in females (χ2 = 195.449, df = 1, P < 0.001). Additional research is needed to prove that appropriate information for patients about the discomfort during 3.0 T MRI and their psychological preparation is very important element for optimal use of 3.0 T MRI in daily clinical practice.展开更多
目的评价3.0 T MRI检查在肝硬化再生性结节(RN)、异型增生性结节(DN)和小肝癌(SHCC)诊断和鉴别诊断中价值。方法回顾性分析经病理检查确诊的69例RN、DN及SHCC患者的3.0 T MRI平扫及容积采集技术(LAVA)三期动态增强扫描特点。结果 RN主...目的评价3.0 T MRI检查在肝硬化再生性结节(RN)、异型增生性结节(DN)和小肝癌(SHCC)诊断和鉴别诊断中价值。方法回顾性分析经病理检查确诊的69例RN、DN及SHCC患者的3.0 T MRI平扫及容积采集技术(LAVA)三期动态增强扫描特点。结果 RN主要表现为T2WI低信号,动态增强方式呈"缓慢上升型";DN主要表现为T2WI高、低信号,信号较均匀结节的动态方式以"速升缓降型"为主,可有"结中结"(特征表现);SHCC主要表现为T1WI低信号、T2WI高信号,动态增强方式为"速升速降型"。结论肝硬化结节及小肝癌在3.0 T MRI上各有较为典型的表现,临床可据此进行诊断与鉴别诊断;对其他强化类型的肝脏病灶应结合肿瘤血管的扭曲增粗及包膜等表现排除SHCC。展开更多
目的比较3.0 T磁共振(MRI)动态增强与64层螺旋CT(64-MDCT)多期扫描对肝硬化背景下小肝癌的诊断价值。方法选择肝硬化合并小肝癌患者55例(66个癌性小结节),分别进行3.0 T MRI动态增强与64-MDCT多期扫描,由两位专家对检查结果进行判定,比...目的比较3.0 T磁共振(MRI)动态增强与64层螺旋CT(64-MDCT)多期扫描对肝硬化背景下小肝癌的诊断价值。方法选择肝硬化合并小肝癌患者55例(66个癌性小结节),分别进行3.0 T MRI动态增强与64-MDCT多期扫描,由两位专家对检查结果进行判定,比较两种检查方法的诊断价值。结果两位观察者通过3.0 T MRI动态增强得到的ROC曲线下面积(AUC)分别为0.893±0.013、0.859±0.027,通过64-MDCT得到的AUC分别为0.657±0.034、0.679±0.026;两位观察者对两种检查方法的诊断价值比较,P均<0.01。两位观察者采用3.0T MRI动态增强诊断肝硬化背景下小肝癌的敏感度、特异度、阴性预测值均高于64-MDCT,P均<0.01。结论 3.0T MRI动态增强对肝硬化背景下小肝癌的诊断价值高于64-MDCT。展开更多
目的分析3.0 T高分辨率磁共振成像(3.0 T HR-MRI)评估椎-基底动脉粥样硬化斑块稳定性在短暂性脑缺血发作(TIA)的应用价值。方法选取2015年2月至2018年2月期间于本院诊治的TIA患者80例,所有患者均行3.0 T HR-MRI检查出椎-基底动脉粥样硬...目的分析3.0 T高分辨率磁共振成像(3.0 T HR-MRI)评估椎-基底动脉粥样硬化斑块稳定性在短暂性脑缺血发作(TIA)的应用价值。方法选取2015年2月至2018年2月期间于本院诊治的TIA患者80例,所有患者均行3.0 T HR-MRI检查出椎-基底动脉粥样硬化斑块,记录椎-基底动脉粥样硬化斑块分布和厚度,并根据斑块稳定性将患者分为斑块稳定组(n=38)和斑块不稳定组(n=42),比较两组患者TIA发作次数以及发作持续时间,门诊随访1年,比较两组患者脑梗死或TIA再发时间、TIA再发次数及脑梗死例数。结果椎-基底动脉粥样硬化斑块最容易在背侧壁形成,斑块厚度以0.5~1.5mm为主;斑块不稳定组患者TIA发作次数显著多于斑块稳定组患者(P<0.05),TIA发作持续时间显著长于斑块稳定组患者(P<0.05);随访1年发现,斑块不稳定组患者脑梗死或TIA再次发作时间显著短于斑块稳定组患者(P<0.05),TIA发作次数、脑梗死例数高于斑块稳定组患者(P<0.05)。结论3.0 T HR-MRI能够评估椎-基底动脉粥样硬化斑块分布、厚度等情况,并对斑块进行定性分析,进一步预测TIA病情发展,为脑血管病二级预防提供更多依据。展开更多
Different causative factors acting on the pancreas can result in diseases such as pancreatitis, diabetes and pancreatic tumors. The high incidence and mortality of pancreatic diseases have placed diagnostic imaging in...Different causative factors acting on the pancreas can result in diseases such as pancreatitis, diabetes and pancreatic tumors. The high incidence and mortality of pancreatic diseases have placed diagnostic imaging in a crucial position in daily clinical practice. In this minireview article different pancreatic imaging techniques are discussed, from the standard clinical imaging modalities and state of the art clinical magnetic resonance imaging techniques to current situations in pre-clinical pancreatic imaging studies. In particular, the challenges of pre-clinical rodent pancreatic imaging are addressed, with both the image acquisition techniques and the post-processing methods for rodent pancreatic imaging elaborated.展开更多
With the development of tissue engineering and regenerative medicine,it is much desired to establish bioimaging techniques to monitor the real-time regeneration efficacy in vivo in a non-invasive way.Herein,we tried m...With the development of tissue engineering and regenerative medicine,it is much desired to establish bioimaging techniques to monitor the real-time regeneration efficacy in vivo in a non-invasive way.Herein,we tried magnetic resonance imaging(MRI)to evaluate knee cartilage regeneration after implanting a biomaterial scaffold seeded with chondrocytes,namely,matrix-induced autologous chondrocyte implantation(MACI).After summary of the T2 mapping and the T1-related delayed gadolinium-enhanced MRI imaging of cartilage(dGEMRIC)in vitro and in vivo in the literature,these two MRI techniques were tried clinically.In this study,18 patients were followed up for 1 year.It was found that there was a significant difference between the regeneration site and the neighboring normal site(control),and the difference gradually diminished with regeneration time up to 1 year according to both the quantitative T1 and T2 MRI methods.We further established the correlation between the quantitative evaluation of MRI and the clinical Lysholm scores for the first time.Hence,the MRI technique was confirmed to be a feasible semiquantitative yet non-invasive way to evaluate the in vivo regeneration of knee articular cartilage.展开更多
文摘Increased interest of clinicians for using 3.0 T magnetic resonance imaging (MRI), as imaging modality of choice for their patients, has been evident in the past few years. The aim of this study was to compare the technical quality of the obtained tomography using 3.0 T and 1.5 T MRI, and to compare the subjective feeling of discomfort of patients and subjective acoustic noise experience during imaging using MRI at 3.0 T and 1.5 T. Brain MRI (1.5 and 3.0 T) was performed in 58 patients, according to a standardized protocol. All studies have been randomly described by independent two radiologists. The reference standard for the existence of technical artifact is established on the basis of both radiologists’ consensus. We also compared the subjective feelings of the discomfort and acoustic noise during the both MRI (1.5 T and 3.0 T) exams. Artifacts were significantly more common during 3.0 T MRI in comparison with the 1.5 T MRI (χ2 = 5.286, P < 0.05), as well as in male patients (χ2 = 8.841, P < 0.05), and sub-jective assessments of discomfort and acoustic noise were higher in patients who underwent imaging using 3.0 T MRI, (χ2 = 125.959, df = 1, P < 0.001) and in females (χ2 = 195.449, df = 1, P < 0.001). Additional research is needed to prove that appropriate information for patients about the discomfort during 3.0 T MRI and their psychological preparation is very important element for optimal use of 3.0 T MRI in daily clinical practice.
文摘目的评价3.0 T MRI检查在肝硬化再生性结节(RN)、异型增生性结节(DN)和小肝癌(SHCC)诊断和鉴别诊断中价值。方法回顾性分析经病理检查确诊的69例RN、DN及SHCC患者的3.0 T MRI平扫及容积采集技术(LAVA)三期动态增强扫描特点。结果 RN主要表现为T2WI低信号,动态增强方式呈"缓慢上升型";DN主要表现为T2WI高、低信号,信号较均匀结节的动态方式以"速升缓降型"为主,可有"结中结"(特征表现);SHCC主要表现为T1WI低信号、T2WI高信号,动态增强方式为"速升速降型"。结论肝硬化结节及小肝癌在3.0 T MRI上各有较为典型的表现,临床可据此进行诊断与鉴别诊断;对其他强化类型的肝脏病灶应结合肿瘤血管的扭曲增粗及包膜等表现排除SHCC。
文摘目的比较3.0 T磁共振(MRI)动态增强与64层螺旋CT(64-MDCT)多期扫描对肝硬化背景下小肝癌的诊断价值。方法选择肝硬化合并小肝癌患者55例(66个癌性小结节),分别进行3.0 T MRI动态增强与64-MDCT多期扫描,由两位专家对检查结果进行判定,比较两种检查方法的诊断价值。结果两位观察者通过3.0 T MRI动态增强得到的ROC曲线下面积(AUC)分别为0.893±0.013、0.859±0.027,通过64-MDCT得到的AUC分别为0.657±0.034、0.679±0.026;两位观察者对两种检查方法的诊断价值比较,P均<0.01。两位观察者采用3.0T MRI动态增强诊断肝硬化背景下小肝癌的敏感度、特异度、阴性预测值均高于64-MDCT,P均<0.01。结论 3.0T MRI动态增强对肝硬化背景下小肝癌的诊断价值高于64-MDCT。
文摘目的分析3.0 T高分辨率磁共振成像(3.0 T HR-MRI)评估椎-基底动脉粥样硬化斑块稳定性在短暂性脑缺血发作(TIA)的应用价值。方法选取2015年2月至2018年2月期间于本院诊治的TIA患者80例,所有患者均行3.0 T HR-MRI检查出椎-基底动脉粥样硬化斑块,记录椎-基底动脉粥样硬化斑块分布和厚度,并根据斑块稳定性将患者分为斑块稳定组(n=38)和斑块不稳定组(n=42),比较两组患者TIA发作次数以及发作持续时间,门诊随访1年,比较两组患者脑梗死或TIA再发时间、TIA再发次数及脑梗死例数。结果椎-基底动脉粥样硬化斑块最容易在背侧壁形成,斑块厚度以0.5~1.5mm为主;斑块不稳定组患者TIA发作次数显著多于斑块稳定组患者(P<0.05),TIA发作持续时间显著长于斑块稳定组患者(P<0.05);随访1年发现,斑块不稳定组患者脑梗死或TIA再次发作时间显著短于斑块稳定组患者(P<0.05),TIA发作次数、脑梗死例数高于斑块稳定组患者(P<0.05)。结论3.0 T HR-MRI能够评估椎-基底动脉粥样硬化斑块分布、厚度等情况,并对斑块进行定性分析,进一步预测TIA病情发展,为脑血管病二级预防提供更多依据。
文摘Different causative factors acting on the pancreas can result in diseases such as pancreatitis, diabetes and pancreatic tumors. The high incidence and mortality of pancreatic diseases have placed diagnostic imaging in a crucial position in daily clinical practice. In this minireview article different pancreatic imaging techniques are discussed, from the standard clinical imaging modalities and state of the art clinical magnetic resonance imaging techniques to current situations in pre-clinical pancreatic imaging studies. In particular, the challenges of pre-clinical rodent pancreatic imaging are addressed, with both the image acquisition techniques and the post-processing methods for rodent pancreatic imaging elaborated.
基金supported by National Key Research and Development Program of China(grant no.2018YFC1105900,2016YFC1100300 and 2016YFC1103203)National Natural Science Foundation of China(grant no.21961160721).
文摘With the development of tissue engineering and regenerative medicine,it is much desired to establish bioimaging techniques to monitor the real-time regeneration efficacy in vivo in a non-invasive way.Herein,we tried magnetic resonance imaging(MRI)to evaluate knee cartilage regeneration after implanting a biomaterial scaffold seeded with chondrocytes,namely,matrix-induced autologous chondrocyte implantation(MACI).After summary of the T2 mapping and the T1-related delayed gadolinium-enhanced MRI imaging of cartilage(dGEMRIC)in vitro and in vivo in the literature,these two MRI techniques were tried clinically.In this study,18 patients were followed up for 1 year.It was found that there was a significant difference between the regeneration site and the neighboring normal site(control),and the difference gradually diminished with regeneration time up to 1 year according to both the quantitative T1 and T2 MRI methods.We further established the correlation between the quantitative evaluation of MRI and the clinical Lysholm scores for the first time.Hence,the MRI technique was confirmed to be a feasible semiquantitative yet non-invasive way to evaluate the in vivo regeneration of knee articular cartilage.