Several new light minimum times for the eclipsing binary GSC 0445-1993 have been determined from the observations by Koppelman et al. and the orbital period of this system was revised. A photometric analysis was carri...Several new light minimum times for the eclipsing binary GSC 0445-1993 have been determined from the observations by Koppelman et al. and the orbital period of this system was revised. A photometric analysis was carried out using the 2003 version of the Wilson-Devinney code. The results reveal that GSC 0445-1993 is a W-type eclipsing binary with a mass ratio of q = 0.323(±0.002) and an over-contact degree of f = 22.8%(±4.2%). A small temperature difference between the components of △T = 135 K and an orbital inclination of i = 65.7°(±0.3°) were obtained. The asymmetry of its light curve (i.e., the O'Connell effect) for this binary star is explained by the presence of a dark spot on the more massive component.展开更多
In the present study, the air quality is assessed for the year 2010 regarding to the Total Suspended Particles (TSP) for six cities of Sonora, Mexico, representing the first regional study in Sonora in air quality. Th...In the present study, the air quality is assessed for the year 2010 regarding to the Total Suspended Particles (TSP) for six cities of Sonora, Mexico, representing the first regional study in Sonora in air quality. The assessment used performance indicators and indicators of compliance with the regulations. It is established that in all the cities the maximum limit value of daily concentration of 210 μg/m3 is exceeded, being the percentage of days above the rule of 30%, 78%, 76%, 6%, 3% and 62% for Agua Prieta, Nogales, Puerto Penasco, Hermosillo, Guaymas and Obregón respectively, classifying these days with poor air quality. According to the annualized index used, the air quality was not satisfactory for the period of study in the six cities. Nogales and Puerto Penasco presented the most adverse conditions of air quality with annual average values of TSP of 363 and 345 μg/m3 and maximum daily of 1047 and 1239 μg/m3 (498% and 590% above the norm) respectively. The requirements of coverage that establishes the Mexican Official Standard NOM-025-SSA1-1993 (SSA, 2005) are questioned for its compliance, proposing in this paper a criterion of non-compliance by prioritizing the protection of health and the precautionary principle. It is recommended to implement air quality management programs (PROAIRE) in these cities.展开更多
基金Supported by the Chinese Academy of Sciences (No. KJCXZSW-T06)The Science and Technology Department of Yunnan Province (2003RC19).
文摘Several new light minimum times for the eclipsing binary GSC 0445-1993 have been determined from the observations by Koppelman et al. and the orbital period of this system was revised. A photometric analysis was carried out using the 2003 version of the Wilson-Devinney code. The results reveal that GSC 0445-1993 is a W-type eclipsing binary with a mass ratio of q = 0.323(±0.002) and an over-contact degree of f = 22.8%(±4.2%). A small temperature difference between the components of △T = 135 K and an orbital inclination of i = 65.7°(±0.3°) were obtained. The asymmetry of its light curve (i.e., the O'Connell effect) for this binary star is explained by the presence of a dark spot on the more massive component.
基金supported by the Institute of Engineering of the Autonomous University of Baja California,also by to the Industrial Environmental Engineering Program of the Sonora State University,and the Division of Engineering,Department of Chemical Engineering and Metallurgy of the University of Sonora.
文摘In the present study, the air quality is assessed for the year 2010 regarding to the Total Suspended Particles (TSP) for six cities of Sonora, Mexico, representing the first regional study in Sonora in air quality. The assessment used performance indicators and indicators of compliance with the regulations. It is established that in all the cities the maximum limit value of daily concentration of 210 μg/m3 is exceeded, being the percentage of days above the rule of 30%, 78%, 76%, 6%, 3% and 62% for Agua Prieta, Nogales, Puerto Penasco, Hermosillo, Guaymas and Obregón respectively, classifying these days with poor air quality. According to the annualized index used, the air quality was not satisfactory for the period of study in the six cities. Nogales and Puerto Penasco presented the most adverse conditions of air quality with annual average values of TSP of 363 and 345 μg/m3 and maximum daily of 1047 and 1239 μg/m3 (498% and 590% above the norm) respectively. The requirements of coverage that establishes the Mexican Official Standard NOM-025-SSA1-1993 (SSA, 2005) are questioned for its compliance, proposing in this paper a criterion of non-compliance by prioritizing the protection of health and the precautionary principle. It is recommended to implement air quality management programs (PROAIRE) in these cities.