Osteomyelitis of the calcaneus can be a limb threatening diagnosis, which is typically treated with antibiotic therapy with or without partial resection of the bone. Extensive infection of the bone commonly results in...Osteomyelitis of the calcaneus can be a limb threatening diagnosis, which is typically treated with antibiotic therapy with or without partial resection of the bone. Extensive infection of the bone commonly results in limb amputation via transtibial or transfemoral amputation, which can increase morbidity and mortality. This case report involves a 29-year-old male who sustained bilateral calcaneal fracture after a fall, who developed osteomyelitis of the right calcaneus after being treated with internal/external fixation and antibiotic therapy. In order to preserve the limb total calcaneal replacement with 3D printed implant was done.展开更多
BACKGROUND Dentition defect,a common clinical oral disease developed in humans,not only causes masticatory dysfunction and articulation difficulties but also affects facial appearance and increases the burden on the i...BACKGROUND Dentition defect,a common clinical oral disease developed in humans,not only causes masticatory dysfunction and articulation difficulties but also affects facial appearance and increases the burden on the intestinal tract.Restorative treatment is the primary option for this disease.However,traditional restorations have many drawbacks,such as mismatch with the body,low reliability,and incomplete occlusal function recovery.AIM to analyze the efficacy of orthodontics combined with 3D printing guide plate implant restoration in treating patients with dentition defects and its influence on masticatory and phonic functions.METHODS A prospective study was carried out in 86 patients with dentition defects who received implant prosthesis after orthodontic treatment in our hospital between January 2018 and January 2019.Those patients were divided into a control group and an intervention group with 43 patients in each group using a random number table.The control group received traditional implant restoration,whereas the intervention group received 3D printing guide plate implant restoration.Treatment outcomes,cosmetic appearance,dental function,implant deviation,and quality of life were compared between the two groups.RESULTS The overall response rate in the intervention group was significantly higher than that in the control group(95.35%vs 81.40%,χ^(2)=4.071,P=0.044).The number of cases with neatly trimmed cosmetic appearance(χ^(2)=4.497,P=0.034),complete coverage(χ^(2)=4.170,P=0.041),and normal occlusion(χ^(2)=5.512,P=0.019)in the intervention group was higher than that in the control group.After treatment,mastication,swallowing,and articulation were significantly improved in both groups.Masticatory(t=2.980,P=0.004),swallowing(t=2.199,P=0.031),and phonic functions(t=3.950,P=0.004)were better in the intervention group than those in the control group.The deviation value and the deviation angle(t=5.440,P=0.000)at the top(t=6.320,P=0.000)and middle parts of the implants(t=22.295,P=0.000)in the intervention group were lower than those in the control group after treatment.Functional limitations,psychosocial and physical pain and discomfort,and total scores decreased in both groups.The functional limitation(t=2.379,P=0.020),psychosocial(t=2.420,P=0.000),physical pain and discomfort(t=6.581,P=0.000),and total scores(t=2.140,P=0.035)were lower in the intervention group than those in the control group.CONCLUSION Orthodontic treatment combined with 3D printing guide plate implant restoration can significantly improve the masticatory and phonic functions,quality of life,and psychological health of patients with dentition defects.Therefore,it is highly recommended in clinic application.展开更多
[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] ...[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] The cone-beam CT( CBCT) image information of 20 premolars extracted by orthodontic requirement was collected,and a new porous bone bionic dental implant was produced using modeling software and 3D printer. The premolars were divided into two groups( A and B). The universal testing machine was used to test the flexural strength of the two groups and the difference in flexural strength between the two groups was compared through statistics. [Results]Twenty 3D printed porous titanium bone bionic implants were accurately produced; the morphology of group A and group B were extremely similar to each other; the average flexural strength of group A was 2 767. 92 N,while the average flexural strength of group B was 778. 77 N,showing that the average flexural strength of group A was significantly higher than that of group B,and the difference was statistically significant( P < 0. 05).[Conclusions]The personalized porous structure root implants produced by 3D printing technology are very similar to the target tooth morphology,and show high accuracy and small error of production. Besides,the flexural strength of 3D printed personalized porous structure root implants can fully meet the requirements of the maximum occlusal force for dental implant restoration. It is expected to provide a scientific basis for clinical application of 3 D printed porous bionic bone tooth implants.展开更多
Oral antibiotics are often prescribed to prevent infection after implant surgery;however, only a small fraction of the antibiotics can reach the implants. Thus, there are concerns about overusing antibiotics. We desig...Oral antibiotics are often prescribed to prevent infection after implant surgery;however, only a small fraction of the antibiotics can reach the implants. Thus, there are concerns about overusing antibiotics. We designed and fabricated porous implants with interconnecting 3D structures (I3D) and hypothesized that such I3D structures could serve as a depository for antimicrobial agents to prevent infection locally. The implants were either treated with antibiotics or coated with silver nanoparticles (AgNPs) by electrodeposition to test this hypothesis. The antimicrobial assay was conducted, and bacterial growth zones of inhibition (ZOIs) were monitored. Overall, I3D implants resulted in larger ZOIs than did the solid implants, and the center I3D (cI3D)-implant produced the largest ZOI. In the antibiotic treatment testing, the diameters of ZOIs of the solid implant vs. I3D implant were about 14 mm vs. 15 to 18 mm on day 2;however, the diameter quickly reduced to 9 mm on day 3 and 5 mm on days 6 and 8 for the solid implant, while no obvious change of the zone was seen for I3D implants. For the AgNPs coated implants, the ZOIs for the I3D implants were generally greater than the solid implant over four weeks of incubation. A significantly larger ZOI (~1 - 2 mm larger on average) was seen for AgNPs coated I3D implants at 0.1 V - 0.01 M, 0.3 V - 0.01 M, and 1.5 V - 0.01 M treatments compared to AgNPs coated solid implants. Given that we have previously shown that I3D implants can reserve chemoattractants to recruit stem cells to enhance osseointegration, we conclude that implants with the I3D structures could be beneficial not only for osseointegration but also in preventing infection.展开更多
文摘Osteomyelitis of the calcaneus can be a limb threatening diagnosis, which is typically treated with antibiotic therapy with or without partial resection of the bone. Extensive infection of the bone commonly results in limb amputation via transtibial or transfemoral amputation, which can increase morbidity and mortality. This case report involves a 29-year-old male who sustained bilateral calcaneal fracture after a fall, who developed osteomyelitis of the right calcaneus after being treated with internal/external fixation and antibiotic therapy. In order to preserve the limb total calcaneal replacement with 3D printed implant was done.
文摘BACKGROUND Dentition defect,a common clinical oral disease developed in humans,not only causes masticatory dysfunction and articulation difficulties but also affects facial appearance and increases the burden on the intestinal tract.Restorative treatment is the primary option for this disease.However,traditional restorations have many drawbacks,such as mismatch with the body,low reliability,and incomplete occlusal function recovery.AIM to analyze the efficacy of orthodontics combined with 3D printing guide plate implant restoration in treating patients with dentition defects and its influence on masticatory and phonic functions.METHODS A prospective study was carried out in 86 patients with dentition defects who received implant prosthesis after orthodontic treatment in our hospital between January 2018 and January 2019.Those patients were divided into a control group and an intervention group with 43 patients in each group using a random number table.The control group received traditional implant restoration,whereas the intervention group received 3D printing guide plate implant restoration.Treatment outcomes,cosmetic appearance,dental function,implant deviation,and quality of life were compared between the two groups.RESULTS The overall response rate in the intervention group was significantly higher than that in the control group(95.35%vs 81.40%,χ^(2)=4.071,P=0.044).The number of cases with neatly trimmed cosmetic appearance(χ^(2)=4.497,P=0.034),complete coverage(χ^(2)=4.170,P=0.041),and normal occlusion(χ^(2)=5.512,P=0.019)in the intervention group was higher than that in the control group.After treatment,mastication,swallowing,and articulation were significantly improved in both groups.Masticatory(t=2.980,P=0.004),swallowing(t=2.199,P=0.031),and phonic functions(t=3.950,P=0.004)were better in the intervention group than those in the control group.The deviation value and the deviation angle(t=5.440,P=0.000)at the top(t=6.320,P=0.000)and middle parts of the implants(t=22.295,P=0.000)in the intervention group were lower than those in the control group after treatment.Functional limitations,psychosocial and physical pain and discomfort,and total scores decreased in both groups.The functional limitation(t=2.379,P=0.020),psychosocial(t=2.420,P=0.000),physical pain and discomfort(t=6.581,P=0.000),and total scores(t=2.140,P=0.035)were lower in the intervention group than those in the control group.CONCLUSION Orthodontic treatment combined with 3D printing guide plate implant restoration can significantly improve the masticatory and phonic functions,quality of life,and psychological health of patients with dentition defects.Therefore,it is highly recommended in clinic application.
文摘[Objectives] To explore the flexural strength of 3D printed titanium bone bionic dental implants and provide a scientific basis for the clinical application of 3D printed porous bionic bone dental implants. [Methods] The cone-beam CT( CBCT) image information of 20 premolars extracted by orthodontic requirement was collected,and a new porous bone bionic dental implant was produced using modeling software and 3D printer. The premolars were divided into two groups( A and B). The universal testing machine was used to test the flexural strength of the two groups and the difference in flexural strength between the two groups was compared through statistics. [Results]Twenty 3D printed porous titanium bone bionic implants were accurately produced; the morphology of group A and group B were extremely similar to each other; the average flexural strength of group A was 2 767. 92 N,while the average flexural strength of group B was 778. 77 N,showing that the average flexural strength of group A was significantly higher than that of group B,and the difference was statistically significant( P < 0. 05).[Conclusions]The personalized porous structure root implants produced by 3D printing technology are very similar to the target tooth morphology,and show high accuracy and small error of production. Besides,the flexural strength of 3D printed personalized porous structure root implants can fully meet the requirements of the maximum occlusal force for dental implant restoration. It is expected to provide a scientific basis for clinical application of 3 D printed porous bionic bone tooth implants.
文摘Oral antibiotics are often prescribed to prevent infection after implant surgery;however, only a small fraction of the antibiotics can reach the implants. Thus, there are concerns about overusing antibiotics. We designed and fabricated porous implants with interconnecting 3D structures (I3D) and hypothesized that such I3D structures could serve as a depository for antimicrobial agents to prevent infection locally. The implants were either treated with antibiotics or coated with silver nanoparticles (AgNPs) by electrodeposition to test this hypothesis. The antimicrobial assay was conducted, and bacterial growth zones of inhibition (ZOIs) were monitored. Overall, I3D implants resulted in larger ZOIs than did the solid implants, and the center I3D (cI3D)-implant produced the largest ZOI. In the antibiotic treatment testing, the diameters of ZOIs of the solid implant vs. I3D implant were about 14 mm vs. 15 to 18 mm on day 2;however, the diameter quickly reduced to 9 mm on day 3 and 5 mm on days 6 and 8 for the solid implant, while no obvious change of the zone was seen for I3D implants. For the AgNPs coated implants, the ZOIs for the I3D implants were generally greater than the solid implant over four weeks of incubation. A significantly larger ZOI (~1 - 2 mm larger on average) was seen for AgNPs coated I3D implants at 0.1 V - 0.01 M, 0.3 V - 0.01 M, and 1.5 V - 0.01 M treatments compared to AgNPs coated solid implants. Given that we have previously shown that I3D implants can reserve chemoattractants to recruit stem cells to enhance osseointegration, we conclude that implants with the I3D structures could be beneficial not only for osseointegration but also in preventing infection.