Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae bet...Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae between the safe con-veyance distance (SCD) of a water pipeline and six influencing factors are established based on the lowest water temper-ature (LWT) along the pipeline axis direction. With reference to the current widely used anti-freeze design approaches for underground pipelines in seasonally frozen areas, this paper first analyzes the feasibility of applying the maximum frozen penetration (MFP) instead of the mean annual ground surface temperature (MAGST) and soil water content (SWC) to calculate the SCD. The results show that the SCD depends on the buried depth if the MFP is fixed and the variation of the MAGST and SWC combination does not significantly change the SCD. A comprehensive formula for the SCD is estab-lished based on the relationships between the SCD and several primary influencing factors and the interaction among them. This formula involves five easy-to-access parameters: the MFP, buried depth, pipeline diameter, flow velocity, and inlet water temperature. A comparison between the analytical method and the numerical results based on the Quasi-3D method indicates that the two methods are in good agreement overall. The analytic method can be used to optimize the anti-freeze design parameters of underground water pipelines in seasonally frozen areas under the condition of a 1.5 safety coefficient.展开更多
A new three-dimensional(3D)cellular model based on hinging open-cell Kelvin structure is proposed for its negative compressibility property.It is shown that this model has adjustable compressibility and does exhibit n...A new three-dimensional(3D)cellular model based on hinging open-cell Kelvin structure is proposed for its negative compressibility property.It is shown that this model has adjustable compressibility and does exhibit negative compressibility for some certain conformations.And further study shows that the images of compressibility are symmetrical about the certain lines,which indicates that the mechanical properties of the model in the three axial directions are interchangeable and the model itself has a certain geometric symmetry.A comparison of the Kelvin model with its anisotropic form with the dodecahedron model shows that the Kelvin model has stronger negative compressibility property in all three directions.Therefore,a new and potential method to improve negative compressibility property can be derived by selecting the system type with lower symmetry and increasing the number of geometric parameters.展开更多
基金financially supported by the National Basic Research Program of China (No. 2013CBA01803)the National Natural Science Foundation of China (No. 41101065)and the CAS "Equipment Development Project for Scientific Research" (No. YZ201523)
文摘Adopting the quasi-three-dimensional (Quasi-3D) numerical method to optimize the anti-freeze design parameters of an underground pipeline usually involves heavy numerical calculations. Here, the fitting formulae between the safe con-veyance distance (SCD) of a water pipeline and six influencing factors are established based on the lowest water temper-ature (LWT) along the pipeline axis direction. With reference to the current widely used anti-freeze design approaches for underground pipelines in seasonally frozen areas, this paper first analyzes the feasibility of applying the maximum frozen penetration (MFP) instead of the mean annual ground surface temperature (MAGST) and soil water content (SWC) to calculate the SCD. The results show that the SCD depends on the buried depth if the MFP is fixed and the variation of the MAGST and SWC combination does not significantly change the SCD. A comprehensive formula for the SCD is estab-lished based on the relationships between the SCD and several primary influencing factors and the interaction among them. This formula involves five easy-to-access parameters: the MFP, buried depth, pipeline diameter, flow velocity, and inlet water temperature. A comparison between the analytical method and the numerical results based on the Quasi-3D method indicates that the two methods are in good agreement overall. The analytic method can be used to optimize the anti-freeze design parameters of underground water pipelines in seasonally frozen areas under the condition of a 1.5 safety coefficient.
基金the National Natural Science Foundation of China(Grant Nos.U1601203 and U19A20104)the Jilin Provincial Science and Technology Development Program,China(Grant Nos.20180101321JC and 20190302099GX)+2 种基金the Jilin Provincial Industrial Technology of Research and Development,China(Grant No.2019C037-3)the Science and Technology Project of Jilin Provincial Department of Education,China(Grant No.JJKH20200955KJ)the Graduate Innovation Fund of Jilin University,China(Grant No.101832018C191).
文摘A new three-dimensional(3D)cellular model based on hinging open-cell Kelvin structure is proposed for its negative compressibility property.It is shown that this model has adjustable compressibility and does exhibit negative compressibility for some certain conformations.And further study shows that the images of compressibility are symmetrical about the certain lines,which indicates that the mechanical properties of the model in the three axial directions are interchangeable and the model itself has a certain geometric symmetry.A comparison of the Kelvin model with its anisotropic form with the dodecahedron model shows that the Kelvin model has stronger negative compressibility property in all three directions.Therefore,a new and potential method to improve negative compressibility property can be derived by selecting the system type with lower symmetry and increasing the number of geometric parameters.