期刊文献+
共找到1,024篇文章
< 1 2 52 >
每页显示 20 50 100
Sparse-view neutron CT 3D image reconstruction algorithm based on split Bregman method
1
作者 Teng-Fei Zhu Yang Liu +1 位作者 Zhi Luo Xiao-Ping Ouyang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期41-55,共15页
As a complement to X-ray computed tomography(CT),neutron tomography has been extensively used in nuclear engineer-ing,materials science,cultural heritage,and industrial applications.Reconstruction of the attenuation m... As a complement to X-ray computed tomography(CT),neutron tomography has been extensively used in nuclear engineer-ing,materials science,cultural heritage,and industrial applications.Reconstruction of the attenuation matrix for neutron tomography with a traditional analytical algorithm requires hundreds of projection views in the range of 0°to 180°and typically takes several hours to complete.Such a low time-resolved resolution degrades the quality of neutron imaging.Decreasing the number of projection acquisitions is an important approach to improve the time resolution of images;however,this requires efficient reconstruction algorithms.Therefore,sparse-view reconstruction algorithms in neutron tomography need to be investigated.In this study,we investigated the three-dimensional reconstruction algorithm for sparse-view neu-tron CT scans.To enhance the reconstructed image quality of neutron CT,we propose an algorithm that uses OS-SART to reconstruct images and a split Bregman to solve for the total variation(SBTV).A comparative analysis of the performances of each reconstruction algorithm was performed using simulated and actual experimental data.According to the analyzed results,OS-SART-SBTV is superior to the other algorithms in terms of denoising,suppressing artifacts,and preserving detailed structural information of images. 展开更多
关键词 Neutron CT OS-SART Sparse-view 3D reconstruction Split Bregman Total variation
下载PDF
Development of Multi-Agent-Based Indoor 3D Reconstruction
2
作者 Hoi Chuen Cheng Frederick Ziyang Hong +2 位作者 Babar Hussain Yiru Wang Chik Patrick Yue 《Computers, Materials & Continua》 SCIE EI 2024年第10期161-181,共21页
Large-scale indoor 3D reconstruction with multiple robots faces challenges in core enabling technologies.This work contributes to a framework addressing localization,coordination,and vision processing for multi-agent ... Large-scale indoor 3D reconstruction with multiple robots faces challenges in core enabling technologies.This work contributes to a framework addressing localization,coordination,and vision processing for multi-agent reconstruction.A system architecture fusing visible light positioning,multi-agent path finding via reinforcement learning,and 360°camera techniques for 3D reconstruction is proposed.Our visible light positioning algorithm leverages existing lighting for centimeter-level localization without additional infrastructure.Meanwhile,a decentralized reinforcement learning approach is developed to solve the multi-agent path finding problem,with communications among agents optimized.Our 3D reconstruction pipeline utilizes equirectangular projection from 360°cameras to facilitate depth-independent reconstruction from posed monocular images using neural networks.Experimental validation demonstrates centimeter-level indoor navigation and 3D scene reconstruction capabilities of our framework.The challenges and limitations stemming from the above enabling technologies are discussed at the end of each corresponding section.In summary,this research advances fundamental techniques for multi-robot indoor 3D modeling,contributing to automated,data-driven applications through coordinated robot navigation,perception,and modeling. 展开更多
关键词 Multi-agent system multi-robot human collaboration visible light communication visible light positioning 3D reconstruction reinforcement learning multi-agent path finding
下载PDF
SAR regional all-azimuth observation orbit design for target 3D reconstruction
3
作者 WANG Yanan ZHOU Chaowei +1 位作者 LIU Aifang MAO Qin 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期609-618,共10页
Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, ... Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, e.g. SAR interferometry(InSAR) and SAR tomography(TomoSAR), holographic SAR can retrieve 3D structure by observations in azimuth. This paper focuses on designing a novel type of orbit to achieve SAR regional all-azimuth observation(AAO) for embedded targets detection and holographic 3D reconstruction. The ground tracks of the AAO orbit separate the earth surface into grids. Target in these grids can be accessed with an azimuth angle span of360°, which is similar to the flight path of airborne circular SAR(CSAR). Inspired from the successive coverage orbits of optical sensors, several optimizations are made in the proposed method to ensure favorable grazing angles, the performance of 3D reconstruction, and long-term supervision for SAR sensors. Simulation experiments show the regional AAO can be completed within five hours. In addition, a second AAO of the same area can be duplicated in two days. Finally, an airborne SAR data process result is presented to illustrate the significance of AAO in 3D reconstruction. 展开更多
关键词 synthetic aperture radar(SAR) orbit design all-azimuth observation(AAO) three-dimensional(3D)reconstruction successive coverage
下载PDF
Efficacy of laparoscopic low anterior resection for colorectal cancer patients with 3D-vascular reconstruction for left coronary artery preservation
4
作者 Ye Wang Zhi-Sheng Liu +2 位作者 Zong-Bao Wang Shawn Liu Feng-Bo Sun 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1548-1557,共10页
BACKGROUND Laparoscopic low anterior resection(LLAR)has become a mainstream surgical method for the treatment of colorectal cancer,which has shown many advantages in the aspects of surgical trauma and postoperative re... BACKGROUND Laparoscopic low anterior resection(LLAR)has become a mainstream surgical method for the treatment of colorectal cancer,which has shown many advantages in the aspects of surgical trauma and postoperative rehabilitation.However,the effect of surgery on patients'left coronary artery and its vascular reconstruction have not been deeply discussed.With the development of medical imaging technology,3D vascular reconstruction has become an effective means to evaluate the curative effect of surgery.AIM To investigate the clinical value of preoperative 3D vascular reconstruction in LLAR of rectal cancer with the left colic artery(LCA)preserved.METHODS A retrospective cohort study was performed to analyze the clinical data of 146 patients who underwent LLAR for rectal cancer with LCA preservation from January to December 2023 in our hospital.All patients underwent LLAR of rectal cancer with the LCA preserved,and the intraoperative and postoperative data were complete.The patients were divided into a reconstruction group(72 patients)and a nonreconstruction group(74 patients)according to whether 3D vascular reconstruction was performed before surgery.The clinical features,operation conditions,complications,pathological results and postoperative recovery of the two groups were collected and compared.RESULTS A total of 146 patients with rectal cancer were included in the study,including 72 patients in the reconstruction group and 74 patients in the nonreconstruction group.There were 47 males and 25 females in the reconstruction group,aged(59.75±6.2)years,with a body mass index(BMI)(24.1±2.2)kg/m^(2),and 51 males and 23 females in the nonreconstruction group,aged(58.77±6.1)years,with a BMI(23.6±2.7)kg/m^(2).There was no significant difference in the baseline data between the two groups(P>0.05).In the submesenteric artery reconstruction group,35 patients were type Ⅰ,25 patients were type Ⅱ,11 patients were type Ⅲ,and 1 patient was type Ⅳ.There were 37 type Ⅰ patients,24 type Ⅱ patients,12 type Ⅲ patients,and 1 type Ⅳ patient in the nonreconstruction group.There was no significant difference in arterial typing between the two groups(P>0.05).The operation time of the reconstruction group was 162.2±10.8 min,and that of the nonreconstruction group was 197.9±19.1 min.Compared with that of the reconstruction group,the operation time of the two groups was shorter,and the difference was statistically significant(t=13.840,P<0.05).The amount of intraoperative blood loss was 30.4±20.0 mL in the reconstruction group and 61.2±26.4 mL in the nonreconstruction group.The amount of blood loss in the reconstruction group was less than that in the control group,and the difference was statistically significant(t=-7.930,P<0.05).The rates of anastomotic leakage(1.4%vs 1.4%,P=0.984),anastomotic hemorrhage(2.8%vs 4.1%,P=0.672),and postoperative hospital stay(6.8±0.7 d vs 7.0±0.7 d,P=0.141)were not significantly different between the two groups.CONCLUSION Preoperative 3D vascular reconstruction technology can shorten the operation time and reduce the amount of intraoperative blood loss.Preoperative 3D vascular reconstruction is recommended to provide an intraoperative reference for laparoscopic low anterior resection with LCA preservation. 展开更多
关键词 Laparoscopic low anterior resection 3D vascular reconstruction Coronary artery Colorectal cancer Retrospective cohort study
下载PDF
Multi-View Image-Based 3D Reconstruction in Indoor Scenes:A Survey
5
作者 LU Ping SHI Wenzhe QIAO Xiuquan 《ZTE Communications》 2024年第3期91-98,共8页
Three-dimensional reconstruction technology plays an important role in indoor scenes by converting objects and structures in indoor environments into accurate 3D models using multi-view RGB images.It offers a wide ran... Three-dimensional reconstruction technology plays an important role in indoor scenes by converting objects and structures in indoor environments into accurate 3D models using multi-view RGB images.It offers a wide range of applications in fields such as virtual reality,augmented reality,indoor navigation,and game development.Existing methods based on multi-view RGB images have made significant progress in 3D reconstruction.These image-based reconstruction methods not only possess good expressive power and generalization performance,but also handle complex geometric shapes and textures effectively.Despite facing challenges such as lighting variations,occlusion,and texture loss in indoor scenes,these challenges can be effectively addressed through deep neural networks,neural implicit surface representations,and other techniques.The technology of indoor 3D reconstruction based on multi-view RGB images has a promising future.It not only provides immersive and interactive virtual experiences but also brings convenience and innovation to indoor navigation,interior design,and virtual tours.As the technology evolves,these image-based reconstruction methods will be further improved to provide higher quality and more accurate solutions to indoor scene reconstruction. 展开更多
关键词 3D reconstruction MVS NeRF neural implicit surface
下载PDF
Equilibrium reconstruction method for self-organized plasmas on reversed field pinches with polarimeter-interferometer
6
作者 Yuhua HUANG Ke LIU +17 位作者 Wenzhe MAO Caoxiang ZHU Tao LAN Yiming ZU Yongkang ZHOU Xingkang WANG Peng DENG Li WANG Pai PENG Adi LIU Chu ZHOU Haifeng LIU Hong LI Jinlin XIE Yuhong XU Weixing DING Wandong LIU Ge ZHUANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期31-40,共10页
In the reversed field pinch(RFP),plasmas exhibit various self-organized states.Among these,the three-dimensional(3D)helical state known as the“quasi-single-helical”(QSH)state enhances RFP confinement.However,accurat... In the reversed field pinch(RFP),plasmas exhibit various self-organized states.Among these,the three-dimensional(3D)helical state known as the“quasi-single-helical”(QSH)state enhances RFP confinement.However,accurately describing the equilibrium is challenging due to the presence of 3D structures,magnetic islands,and chaotic regions.It is difficult to obtain a balance between the available diagnostic and the real equilibrium structure.To address this issue,we introduce KTX3DFit,a new 3D equilibrium reconstruction code specifically designed for the Keda Torus eXperiment(KTX)RFP.KTX3DFit utilizes the stepped-pressure equilibrium code(SPEC)to compute 3D equilibria and uses polarimetric interferometer signals from experiments.KTX3DFit is able to reconstruct equilibria in various states,including axisymmetric,doubleaxis helical(DAx),and single-helical-axis(SHAx)states.Notably,this study marks the first integration of the SPEC code with internal magnetic field data for equilibrium reconstruction and could be used for other 3D configurations. 展开更多
关键词 equilibrium reconstruction polarimeter-interferometer multi-region relaxed MHD 3D self-organized states reversed field pinch
下载PDF
Rapid printing of 3D porous scaffolds for breast reconstruction 被引量:2
7
作者 Pengcheng Zhao Biling Wang +5 位作者 Lu Wang Zexin Fu Jun Hu Yande Liu Ji Wang Yong He 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第6期691-703,共13页
Prosthesis implantation and fat transplantation are common breast reconstructionmethods.In general,prosthesis implantation alone does not achieve a realistic enough appearance,and fat transplantation alone is difficul... Prosthesis implantation and fat transplantation are common breast reconstructionmethods.In general,prosthesis implantation alone does not achieve a realistic enough appearance,and fat transplantation alone is difficult to achieve in the correct capacity.To date,no reports have focused on methods of combining fat with implanted prostheses for breast reconstruction.Using a newly designed bionic ink(i.e.,polyether F127 diacrylate(F127DA)&poly(ethylene glycol)diacrylate(PEGDA))and projection-based three-dimensional bioprinting(PBP),we report the development of a new method for printing porous prostheses.PEGDA was used to improve the printing precision of the prosthesis by increasing the gel point of F127DA and reducing the impact of external temperature.The compression modulus of the printed prosthesis was very close to that of prostheses currently used in clinical practice and to that of natural breasts.Finally,stromal vascular fraction gel(SVF-gel),a human fat extract,was injected into the pores of the synthesized prostheses to prepare a prosthesis mixed with adipose tissue.These were implanted subcutaneously in nude mice to observe their biological performance.After 14 and 28 days of observation,the prosthesis showed good biocompatibility,and adipose tissues grew well in and around the prosthesis.This result shows that a porous prosthesis containing pre-placed adipose tissues is a promising breast reconstruction material. 展开更多
关键词 Projection-based 3D bioprinting(PBP) F127DA Breast reconstruction Fat transplantation
下载PDF
Parallel computing approach for efficient 3-D X-ray-simulated image reconstruction 被引量:1
8
作者 Ou-Yi Li Yang Wang +1 位作者 Qiong Zhang Yong-Hui Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第7期122-136,共15页
Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method... Accurate 3-dimensional(3-D)reconstruction technology for nondestructive testing based on digital radiography(DR)is of great importance for alleviating the drawbacks of the existing computed tomography(CT)-based method.The commonly used Monte Carlo simulation method ensures well-performing imaging results for DR.However,for 3-D reconstruction,it is limited by its high time consumption.To solve this problem,this study proposes a parallel computing method to accelerate Monte Carlo simulation for projection images with a parallel interface and a specific DR application.The images are utilized for 3-D reconstruction of the test model.We verify the accuracy of parallel computing for DR and evaluate the performance of two parallel computing modes-multithreaded applications(G4-MT)and message-passing interfaces(G4-MPI)-by assessing parallel speedup and efficiency.This study explores the scalability of the hybrid G4-MPI and G4-MT modes.The results show that the two parallel computing modes can significantly reduce the Monte Carlo simulation time because the parallel speedup increment of Monte Carlo simulations can be considered linear growth,and the parallel efficiency is maintained at a high level.The hybrid mode has strong scalability,as the overall run time of the 180 simulations using 320 threads is 15.35 h with 10 billion particles emitted,and the parallel speedup can be up to 151.36.The 3-D reconstruction of the model is achieved based on the filtered back projection(FBP)algorithm using 180 projection images obtained with the hybrid G4-MPI and G4-MT.The quality of the reconstructed sliced images is satisfactory because the images can reflect the internal structure of the test model.This method is applied to a complex model,and the quality of the reconstructed images is evaluated. 展开更多
关键词 Parallel computing Monte Carlo Digital radiography 3-D reconstruction
下载PDF
3D printing of personalized polylactic acid scaffold laden with GelMA/autologous auricle cartilage to promote ear reconstruction 被引量:1
9
作者 Xingyu Gui Zhiyu Peng +13 位作者 Ping Song Li Chen Xiujuan Xu Hairui Li Pei Tang Yixi Wang Zixuan Su Qingquan Kong Zhenyu Zhang Zhengyong Li Ying Cen Changchun Zhou Yujiang Fan Xingdong Zhang 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第4期451-463,共13页
At present,the clinical reconstruction of the auricle usually adopts the strategy of taking autologous costal cartilage.This method has great trauma to patients,poor plasticity and inaccurate shaping.Three-dimensional... At present,the clinical reconstruction of the auricle usually adopts the strategy of taking autologous costal cartilage.This method has great trauma to patients,poor plasticity and inaccurate shaping.Three-dimensional(3D)printing technology has made a great breakthrough in the clinical application of orthopedic implants.This study explored the combination of 3D printing and tissue engineering to precisely reconstruct the auricle.First,a polylactic acid(PLA)polymer scaffold with a precisely customized patient appearance was fabricated,and then auricle cartilage fragments were loaded into the 3D-printed porous PLA scaffold to promote auricle reconstruction.In vitro,gelatin methacrylamide(GelMA)hydrogels loaded with different sizes of rabbit ear cartilage fragments were studied to assess the regenerative activity of various autologous cartilage fragments.In vivo,rat ear cartilage fragments were placed in an accurately designed porous PLA polymer ear scaffold to promote auricle reconstruction.The results indicated that the chondrocytes in the cartilage fragments could maintain the morphological phenotype in vitro.After three months of implantation observation,it was conducive to promoting the subsequent regeneration of cartilage in vivo.The autologous cartilage fragments combined with 3D printing technology show promising potential in auricle reconstruction. 展开更多
关键词 MICROTIA 3D printing Polylactic acid(PLA)polymer scaffolds Gelatin methacrylamide Cartilage reconstruction
下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint 被引量:1
10
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
下载PDF
Preoperative 3D reconstruction and fluorescent indocyanine green for laparoscopic duodenum preserving pancreatic head resection:A case report 被引量:1
11
作者 Xiao-Li Li Lian-Sheng Gong 《World Journal of Clinical Cases》 SCIE 2023年第4期903-908,共6页
BACKGROUND Duodenum-preserving pancreatic head resection(DPPHR)is the choice of surgery for benign or low-grade malignant tumors of the pancreatic head.Laparoscopic DPPHR(LDPPHR)procedure can be improved by preoperati... BACKGROUND Duodenum-preserving pancreatic head resection(DPPHR)is the choice of surgery for benign or low-grade malignant tumors of the pancreatic head.Laparoscopic DPPHR(LDPPHR)procedure can be improved by preoperative 3D model reconstruction and the use of intravenous indocyanine green fluorescent before surgery for real-time navigation with fluorescent display to guide the surgical dissection and prevention of from injury to vessels and biliary tract.CASE SUMMARY Here we report the successful short-and long-term outcomes after one year following LDPPHR for a 60-year lady who had an uneventful recovery and was discharged home one week after the surgery.CONCLUSION There was no bile leakage or pancreatic leakage or delayed gastric emptying.The histopathology report showed multiple cysts in the pancreatic head and localized pancreatic intraepithelial tumor lesions.The resected margin was free of tumor. 展开更多
关键词 Duodenum-preserving pancreatic head resection Fluorescent navigation Laparoscopic 3D model reconstruction Case report
下载PDF
Accurate resection of hilar cholangiocarcinoma using eOrganmap 3D reconstruction and full quantization technique 被引量:1
12
作者 Da-Peng Cui Shuang Fan +3 位作者 Ying-Xue Guo Qian-Wei Zhao Yue-Xin Qiao Jian-Dong Fei 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第8期1693-1702,共10页
BACKGROUND For treatment of hilar cholangiocarcinoma(HCCA),the rate of radical resection is low and prognosis is poor,and preoperative evaluation is not sufficiently accurate.3D visualization has the advantage of givi... BACKGROUND For treatment of hilar cholangiocarcinoma(HCCA),the rate of radical resection is low and prognosis is poor,and preoperative evaluation is not sufficiently accurate.3D visualization has the advantage of giving a stereoscopic view,which makes accurate resection of HCCA possible.AIM To establish precise resection of HCCA based on eOrganmap 3D reconstruction and full quantification technology.METHODS We retrospectively analyzed the clinical data of 73 patients who underwent HCCA surgery.All patients were assigned to two groups.The traditional group received traditional 2D imaging planning before surgery(n=35).The eOrganmap group underwent 3D reconstruction and full quantitative technical planning before surgery(n=38).The preoperative evaluation,anatomical classification of hilar hepatic vessels,indicators associated with surgery,postoperative complications,liver function,and stress response indexes were compared between the groups.RESULTS Compared with the traditional group,the amount of intraoperative blood loss in the eOrganmap group was lower,the operating time and postoperative intestinal ventilation time were shorter,and R0 resection rate and lymph node dissection number were higher(P<0.05).The total complication rate in the eOrganmap group was 21.05%compared with 25.71%in the traditional group(P>0.05).The levels of total bilirubin,Albumin(ALB),aspartate transaminase,and alanine transaminase in the eOrganmap group were significantly different from those in the traditional group(intergroup effect:F=450.400,79.120,95.730,and 13.240,respectively;all P<0.001).Total bilirubin,aspartate transaminase,and alanine transaminase in both groups showed a decreasing trend with time(time effect:F=30.270,17.340,and 13.380,respectively;all P<0.001).There was an interaction between patient group and time(interaction effect:F=3.072,2.965,and 2.703,respectively;P=0.0282,0.032,and 0.046,respectively);ALB levels in both groups tended to increase with time(time effect:F=22.490,P<0.001),and there was an interaction effect between groups and time(interaction effect:F=4.607,P=0.004).In the eOrganmap group,there was a high correlation between the actual volume of intraoperative liver specimen resection and the volume of preoperative virtual liver resection(t=0.916,P<0.001).CONCLUSION The establishment of accurate laparoscopic resection of hilar cholangiocarcinoma based on preoperative eOrganmap 3D reconstruction and full quantization technology can make laparoscopic resection of hilar cholangiocarcinoma more accurate and safe. 展开更多
关键词 eOrganmap 3D reconstruction Full quantification technology Laparoscopic surgery Hilar cholangiocarcinoma Precise resection
下载PDF
3D Face Reconstruction from a Single Image Using a Combined PCA-LPP Method
13
作者 Jee-Sic Hur Hyeong-Geun Lee +2 位作者 Shinjin Kang Yeo Chan Yoon Soo Kyun Kim 《Computers, Materials & Continua》 SCIE EI 2023年第3期6213-6227,共15页
In this paper, we proposed a combined PCA-LPP algorithm toimprove 3D face reconstruction performance. Principal component analysis(PCA) is commonly used to compress images and extract features. Onedisadvantage of PCA ... In this paper, we proposed a combined PCA-LPP algorithm toimprove 3D face reconstruction performance. Principal component analysis(PCA) is commonly used to compress images and extract features. Onedisadvantage of PCA is local feature loss. To address this, various studies haveproposed combining a PCA-LPP-based algorithm with a locality preservingprojection (LPP). However, the existing PCA-LPP method is unsuitable for3D face reconstruction because it focuses on data classification and clustering.In the existing PCA-LPP, the adjacency graph, which primarily shows the connectionrelationships between data, is composed of the e-or k-nearest neighbortechniques. By contrast, in this study, complex and detailed parts, such aswrinkles around the eyes and mouth, can be reconstructed by composing thetopology of the 3D face model as an adjacency graph and extracting localfeatures from the connection relationship between the 3D model vertices.Experiments verified the effectiveness of the proposed method. When theproposed method was applied to the 3D face reconstruction evaluation set,a performance improvement of 10% to 20% was observed compared with theexisting PCA-based method. 展开更多
关键词 Principal component analysis locality preserving project 3DMM face reconstruction face modeling
下载PDF
Fast Estimation of Loader’s Shovel Load Volume by 3D Reconstruction of Material Piles
14
作者 Binyun Wu Shaojie Wang +2 位作者 Haojing Lin Shijiang Li Liang Hou 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期187-205,共19页
Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for ... Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for volume measurement, such as total station-based methods, cannot measure the volume in real time, while the bucket-based method also has the disadvantage of poor universality. In this study, a fast estimation method for a loader’s shovel load volume by 3D reconstruction of material piles is proposed. First, a dense stereo matching method (QORB–MAPM) was proposed by integrating the improved quadtree ORB algorithm (QORB) and the maximum a posteriori probability model (MAPM), which achieves fast matching of feature points and dense 3D reconstruction of material piles. Second, the 3D point cloud model of the material piles before and after shoveling was registered and segmented to obtain the 3D point cloud model of the shoveling area, and the Alpha-shape algorithm of Delaunay triangulation was used to estimate the volume of the 3D point cloud model. Finally, a shovel loading volume measurement experiment was conducted under loose-soil working conditions. The results show that the shovel loading volume estimation method (QORB–MAPM VE) proposed in this study has higher estimation accuracy and less calculation time in volume estimation and bucket fll factor estimation, and it has signifcant theoretical research and engineering application value. 展开更多
关键词 LOADER Volume estimation Binocular stereo vision 3D terrain reconstruction Point cloud registration and segmentation
下载PDF
Unveiling the parasitic-reaction-driven surface reconstruction in Ni-rich cathode and the electrochemical role of Li_(2)CO_(3)
15
作者 Jiyu Cai Zhenzhen Yang +18 位作者 Xinwei Zhou Bingning Wang Ana Suzana Jianming Bai Chen Liao Yuzi Liu Yanbin Chen Shunlin Song Xuequan Zhang Li Wang Xiangming He Xiangbo Meng Niloofar Karami Baasit Ali Shaik Sulaiman Natasha A.Chernova Shailesh Upreti Brad Prevel Feng Wang Zonghai Chen 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第10期126-136,I0006,共12页
Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cat... Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energydensity lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cathodes is accompanied by substantial safety and cycle-life obstacles. The major issues of Ni-rich cathodes at high working potentials are originated from the unstable cathode-electrolyte interface, while the underlying mechanism of parasitic reactions towards surface reconstructions of cathode materials is not well understood. In this work, we controlled the Li_(2)CO_(3) impurity content on LiNi_(0.83)Mn_(0.1)Co_(0.07)O_(2) cathodes using air, tank-air, and O_(2) synthesis environments. Home-built high-precision leakage current and on-line electrochemical mass spectroscopy experiments verify that Li_(2)CO_(3) impurity is a significant promoter of parasitic reactions on Ni-rich cathodes. The rate of parasitic reactions is strongly correlated to Li_(2)CO_(3) content and severe performance deterioration of Ni83 cathodes.The post-mortem characterizations via high-resolution transition electron microscope and X-ray photoelectron spectroscopy depth profiles reveal that parasitic reactions promote more Ni reduction and O deficiency and even rock-salt phase transformation at the surface of cathode materials. Our observation suggests that surface reconstructions have a strong affiliation to parasitic reactions that create chemically acidic environment to etch away the lattice oxygen and offer the electrical charge to reduce the valence state of transition metal. Thus, this study advances our understanding on surface reconstructions of Nirich cathodes and prepares us for searching for rational strategies. 展开更多
关键词 Ni-rich cathodes Surface reconstructions Phase transformation Parasitic reactions Li_(2)CO_(3)
下载PDF
3D Echocardiogram Reconstruction Employing a Flip Directional Texture Pyramid
16
作者 C.Preethi M.Mohamed Sathik S.Shajun Nisha 《Computer Systems Science & Engineering》 SCIE EI 2023年第6期2971-2988,共18页
Three dimensional(3D)echocardiogram enables cardiologists to visua-lize suspicious cardiac structures in detail.In recent years,this three-dimensional echocardiogram carries important clinical value in virtual surgica... Three dimensional(3D)echocardiogram enables cardiologists to visua-lize suspicious cardiac structures in detail.In recent years,this three-dimensional echocardiogram carries important clinical value in virtual surgical simulation.However,this 3D echocardiogram involves a trade-off difficulty between accu-racy and efficient computation in clinical diagnosis.This paper presents a novel Flip Directional 3D Volume Reconstruction(FD-3DVR)method for the recon-struction of echocardiogram images.The proposed method consists of two main steps:multiplanar volumetric imaging and 3D volume reconstruction.In the crea-tion of multiplanar volumetric imaging,two-dimensional(2D)image pixels are mapped into voxels of the volumetric grid.As the obtained slices are discontin-uous,there are some missing voxels in the volume data.To restore the structural and textural information of 3D ultrasound volume,the proposed method creates a volume pyramid in parallel with theflip directional texture pyramid.Initially,the nearest neighbors of missing voxels in the multiplanar volumetric imaging are identified by 3D ANN(Approximate Nearest Neighbor)patch matching method.Furthermore,aflip directional texture pyramid is proposed and aggregated with distance in patch matching tofind out the most similar neighbors.In the recon-struction step,structural and textural information obtained from differentflip angle directions can reconstruct 3D volume well with the desired accuracy.Com-pared with existing 3D reconstruction methods,the proposed Flip Directional 3D Volume Reconstruction(FD-3DVR)method provides superior performance for the mean peak signal-to-noise ratio(40.538 for the proposed method I and 39.626 for the proposed method II).Experimental results performed on the cardi-ac datasets demonstrate the efficiency of the proposed method for the reconstruc-tion of echocardiogram images. 展开更多
关键词 Three-dimensional echocardiogram 3D ANN patch matching volume pyramid flip directional texture pyramid 3D volume reconstruction
下载PDF
祖先序列重建增强D-阿洛酮糖3-差向异构酶的热稳定性
17
作者 管立军 朱玲 +7 位作者 王崑仑 李家磊 高扬 严松 张馨笛 陈晴 季妮娜 李波 《食品工业科技》 CAS 北大核心 2024年第21期121-128,共8页
为解决现有D-阿洛酮糖3-差向异构酶(DAEase)热稳定性差的产业问题,本文采用系统发育指导的大数据挖掘、合理修饰和祖先序列重建策略(ASR),重建了具有不同催化结构域DAEase的祖先序列,构建了表达载体,通过重组表达与分子对接筛选出了DAEa... 为解决现有D-阿洛酮糖3-差向异构酶(DAEase)热稳定性差的产业问题,本文采用系统发育指导的大数据挖掘、合理修饰和祖先序列重建策略(ASR),重建了具有不同催化结构域DAEase的祖先序列,构建了表达载体,通过重组表达与分子对接筛选出了DAEase A13并进行酶学性质表征,此外,还基于结构分析与分子动力学模拟揭示了DAEase A13热稳定性增强的分子机制。结果表明,基于ASR策略所构建的A13 70℃时半衰期可达8.4 h,其热稳定性较野生(WT)酶显著增强,最大转化率为31%,催化活性也略高于WT酶。立体结构模拟与分子动力学模拟揭示了ASR A13中大量氢键和疏水作用的增加维持了高温下酶分子结构的稳定性,是其热稳定性增强的主要因素。研究结果证实了ASR策略可以改造DAEase使其稳定性、活性和混杂性增强,可以为D-阿洛酮糖工业生产提供良好的生物催化剂。 展开更多
关键词 祖先序列重建 D-阿洛酮糖 D-阿洛酮糖3-差向异构酶 热稳定性
下载PDF
胃近端切除伴双通道重建手术ICD-9-CM-3编码探讨
18
作者 郭旭升 杨智彬 张璇 《中国医院统计》 2024年第2期153-155,160,共4页
双通道重建理论上是近端胃切除术较为理想的消化道重建方式,由于ICD-9-CM-3词典库更新停滞以及医院端现用手术词典库扩码不足等原因,对于胃近端切除伴双通道重建手术的ICD编码存在一定争议。本文从相关手术的内涵和历史演进等角度,对该... 双通道重建理论上是近端胃切除术较为理想的消化道重建方式,由于ICD-9-CM-3词典库更新停滞以及医院端现用手术词典库扩码不足等原因,对于胃近端切除伴双通道重建手术的ICD编码存在一定争议。本文从相关手术的内涵和历史演进等角度,对该手术的ICD-9-CM-3编码进行了分析探讨。 展开更多
关键词 胃近端切除手术 双通道重建手术 ICD-9-CM-3 手术操作编码
下载PDF
Fast Mesh Reconstruction from Single View Based on GCN and Topology Modification 被引量:1
19
作者 Xiaorui Zhang Feng Xu +2 位作者 Wei Sun Yan Jiang Yi Cao 《Computer Systems Science & Engineering》 SCIE EI 2023年第5期1695-1709,共15页
3D reconstruction based on single view aims to reconstruct the entire 3D shape of an object from one perspective.When existing methods reconstruct the mesh surface of complex objects,the surface details are difficult ... 3D reconstruction based on single view aims to reconstruct the entire 3D shape of an object from one perspective.When existing methods reconstruct the mesh surface of complex objects,the surface details are difficult to predict and the reconstruction visual effect is poor because the mesh representation is not easily integrated into the deep learning framework;the 3D topology is easily limited by predefined templates and inflexible,and unnecessary mesh self-intersections and connections will be generated when reconstructing complex topology,thus destroying the surface details;the training of the reconstruction network is limited by the large amount of information attached to the mesh vertices,and the training time of the reconstructed network is too long.In this paper,we propose a method for fast mesh reconstruction from single view based on Graph Convolutional Network(GCN)and topology modification.We use GCN to ensure the generation of high-quality mesh surfaces and use topology modification to improve the flexibility of the topology.Meanwhile,a feature fusion method is proposed to make full use of the features of each stage of the image hierarchically.We use 3D open dataset ShapeNet to train our network and add a new weight parameter to speed up the training process.Extensive experiments demonstrate that our method can not only reconstruct object meshes on complex topological surfaces,but also has better qualitative and quantitative results. 展开更多
关键词 3D surface reconstruction deep learning GCN topology modification end-to-end framework
下载PDF
Reconstruction and recovery of anatase TiO_(2) from spent selective catalytic reduction catalyst by Na OH hydrothermal method 被引量:2
20
作者 Jinlong Liu Chenye Wang +4 位作者 Xingrui Wang Chen Zhao Huiquan Li Ganyu Zhu Jianbo Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第8期53-60,共8页
The improper disposal of spent selective catalytic reduction (SCR) catalysts causes environmental pollution and metal resource waste.A novel process to recover anatase titanium dioxide (TiO_(2)) from spent SCR catalys... The improper disposal of spent selective catalytic reduction (SCR) catalysts causes environmental pollution and metal resource waste.A novel process to recover anatase titanium dioxide (TiO_(2)) from spent SCR catalysts was proposed.The process included alkali (NaOH) hydrothermal treatment,sulfuric acid washing,and calcination.Anatase TiO_(2) in spent SCR catalyst was reconstructed by forming Na_(2)Ti_(2)O_(4)(OH)_(2) nanosheet during NaOH hydrothermal treatment and H_(2)Ti_(2)O_(4)(OH)_(2) during sulfuric acid washing.Anatase TiO_(2) was recovered by decomposing H_(2)Ti_(2)O_(4)(OH)_(2) during calcination.The surface pore properties of the recovered anatase TiO_(2) were adequately improved,and its specific surface area (SSA) and pore volume (PV) were 85 m^(2)·g^(-1)and 0.40 cm^(3)·g^(-1),respectively.The elements affecting catalytic abilities(arsenic and sodium) were also removed.The SCR catalyst was resynthesized using the recovered TiO_(2) as raw material,and its catalytic performance in NO selective reduction was comparable with that of commercial SCR catalyst.This study realized the sustainable recycling of anatase TiO_(2) from spent SCR catalyst. 展开更多
关键词 TiO_(2)reconstruction Anatase TiO_(2)recovery Pore properties Spent V_(2)O_(5)-WO_(3)/TiO_(2)catalyst
下载PDF
上一页 1 2 52 下一页 到第
使用帮助 返回顶部