期刊文献+
共找到561篇文章
< 1 2 29 >
每页显示 20 50 100
Surface evolution of thermoelectric material KCu_(4)Se_(3) explored by scanning tunneling microscopy
1
作者 夏玉敏 马妮 +7 位作者 蔡德胜 刘宇舟 谷易通 于淦 霍思宇 庞文慧 肖翀 秦胜勇 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期422-427,共6页
Novel two-dimensional thermoelectric materials have attracted significant attention in the field of thermoelectric due to their low lattice thermal conductivity.A comprehensive understanding of their microscopic struc... Novel two-dimensional thermoelectric materials have attracted significant attention in the field of thermoelectric due to their low lattice thermal conductivity.A comprehensive understanding of their microscopic structures is crucial for driving further the optimization of materials properties and developing novel functional materials.Here,by using in situ scanning tunneling microscopy,we report the atomic layer evolution and surface reconstruction on the cleaved thermoelectric material KCu_(4)Se_(3) for the first time.We clearly revealed each atomic layer,including the naturally cleaved K atomic layer,the intermediate Se^(2-)atomic layer,and the Se^(-)atomic layer that emerges in the thermodynamic-stable state.Departing from the maj ority of studies that predominantly concentrate on macroscopic measurements of the charge transport,our results reveal the coexistence of potassium disorder and complex reconstructed patterns of selenium,which potentially influences charge carrier and lattice dynamics.These results provide direct insight into the surface microstructures and evolution of KCu_(4)Se_(3),and shed useful light on designing functional materials with superior performance. 展开更多
关键词 THERMOELECTRIC KCu_(4)Se_(3) scanning tunneling microscopy(STM) EVOLUTION
下载PDF
3shape Trios 3口内扫描和传统硅橡胶在牙体缺损修复中的失败原因分析
2
作者 李娜 《临床医学研究与实践》 2024年第9期85-88,共4页
目的分析并比较3shape Trios 3口内扫描和传统硅橡胶在牙体缺损修复中的失败原因,为临床取模以及口内扫描仪性能改善提供参考依据。方法回顾性分析2021年1月至2023年10月实施口腔固定修复治疗并返工的200例患者为研究对象,以取模方式将... 目的分析并比较3shape Trios 3口内扫描和传统硅橡胶在牙体缺损修复中的失败原因,为临床取模以及口内扫描仪性能改善提供参考依据。方法回顾性分析2021年1月至2023年10月实施口腔固定修复治疗并返工的200例患者为研究对象,以取模方式将其分为口扫组(n=97)和硅橡胶组(n=103)。口扫组给予3shape Trios 3口内扫描,硅橡胶组给予传统硅橡胶。比较两组在牙体缺损修复中的失败原因。结果两组的牙体缺损修复失败分布情况比较,差异具有统计学意义(P<0.05);口扫组中,龈下缺损修复失败占比高于龈上(P<0.05)。两组的龈下缺损修复失败原因比较,差异具有统计学意义(P<0.05)。结论相较于传统硅橡胶,3shape Trios 3口内扫描在龈上缺损修复中更有优势,但在龈下缺损修复中,硅橡胶应用效果更佳。 展开更多
关键词 3shape Trios 3口内扫描 硅橡胶 牙体缺损
下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint 被引量:1
3
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
下载PDF
Method for visualizing the shear process of rock joints using 3D laser scanning and 3D printing techniques
4
作者 Man Huang Chenjie Hong +3 位作者 Peng Sha Shigui Du Zhanyou Luo Zhigang Tao 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第1期204-215,共12页
This study presents a visualized approach for tracking joint surface morphology.Three-dimensional laser scanning(3DLS)and 3D printing(3DP)techniques are adopted to record progressive failure during rock joint shearing... This study presents a visualized approach for tracking joint surface morphology.Three-dimensional laser scanning(3DLS)and 3D printing(3DP)techniques are adopted to record progressive failure during rock joint shearing.The 3DP resin is used to create transparent specimens to reproduce the surface morphology of a natural joint precisely.The freezing method is employed to enhance the mechanical properties of the 3DP specimens to reproduce the properties of hard rock more accurately.A video camera containing a charge-coupled device(CCD)camera is utilized to record the evolution of damaged area of joint surface during the direct shear test.The optimal shooting distance and shooting angle are recommended to be 800 mm and 40?,respectively.The images captured by the CCD camera are corrected to quantitatively describe the damaged area on the joint surface.Verification indicates that this method can accurately describe the total sheared areas at different shear stages.These findings may contribute to elucidating the shear behavior of rock joints. 展开更多
关键词 Rock joint Shear test Three-dimensional printing(3DP) Three-dimensional laser scanning(3DLS) Visualization approach
下载PDF
Application of 3D Scanned Big Data of Large-scale Cultural Heritage Objects Based on Noise-robust Transparent Visualization
5
作者 Tanaka Satoshi 《系统仿真学报》 CAS CSCD 北大核心 2023年第8期1635-1650,共16页
Three-dimensional(3D) scanning technology has undergone remarkable developments in recent years.Data acquired by 3D scanning have the form of 3D point clouds.The 3D scanned point clouds have data sizes that can be con... Three-dimensional(3D) scanning technology has undergone remarkable developments in recent years.Data acquired by 3D scanning have the form of 3D point clouds.The 3D scanned point clouds have data sizes that can be considered big data.They also contain measurement noise inherent in measurement data.These properties of 3D scanned point clouds make many traditional CG/visualization techniques difficult.This paper reviewed our recent achievements in developing varieties of high-quality visualizations suitable for the visual analysis of 3D scanned point clouds.We demonstrated the effectiveness of the method by applying the visualizations to various cultural heritage objects.The main visualization targets used in this paper are the floats in the Gion Festival in Kyoto(the float parade is on the UNESCO Intangible Cultural Heritage List) and Borobudur Temple in Indonesia(a UNESCO World Heritage Site). 展开更多
关键词 3D scanning point cloud transparent visualization noise transparentization cultural heritage object
下载PDF
AlSc15中间合金中Al_(3)Sc金属间化合物的电化学行为及对局部腐蚀的影响
6
作者 蒋伟 高坤元 +6 位作者 胡秀华 文胜平 黄晖 吴晓蓝 魏午 聂祚仁 启世亮 《轻合金加工技术》 CAS 2024年第2期54-58,共5页
将过共晶AlSc15合金加热至液态,以10℃/h速率冷却得到毫米级尺寸的Al_(3)Sc金属间化合物。利用微区电化学和扫描开尔文探针力显微镜(SKPFM)研究了Al_(3)Sc金属间化合物在不同pH值的0.1 mol/L NaCl溶液中的电化学特征及对局部腐蚀敏感性... 将过共晶AlSc15合金加热至液态,以10℃/h速率冷却得到毫米级尺寸的Al_(3)Sc金属间化合物。利用微区电化学和扫描开尔文探针力显微镜(SKPFM)研究了Al_(3)Sc金属间化合物在不同pH值的0.1 mol/L NaCl溶液中的电化学特征及对局部腐蚀敏感性的影响。结果表明,Al_(3)Sc金属间化合物存在自钝化现象,且在碱性环境中有明显的维钝区域;随着pH值的增加,Al_(3)Sc腐蚀电位逐渐降低,在中性和碱性条件下的腐蚀速率明显低于酸性条件下的;Al_(3)Sc金属间化合物与周围铝基体之间的伏打电位差约为40 mV,在铝合金中可能作为较弱的局部阴极,对电偶腐蚀的影响不大。 展开更多
关键词 Al_(3)Sc金属间化合物 微电化学技术 扫描开尔文 局部腐蚀
下载PDF
Research on 3D Laser Scanning Reconstruction of Ancient Buildings Combined with BIM Technology
7
作者 Ensheng Liu Chunyong Luo +1 位作者 Chunbaixue Yang Yuhua Huang 《Journal of Computer and Communications》 2023年第7期233-240,共8页
After more than 30 years of scientific and social development, surveying and mapping technology by leaps and bounds, engineering surveying technology has undergone tremendous changes. In the process of protecting anci... After more than 30 years of scientific and social development, surveying and mapping technology by leaps and bounds, engineering surveying technology has undergone tremendous changes. In the process of protecting ancient buildings, it is necessary to obtain the precise dimensions of architectural details. In this study, the path of 3D laser scanning combined with BIM technology is explored. Taking the observation and protection of the ancestral hall of the Liu family as an example, this study aims to draw drawings that reflect the relevant information about the ancient buildings, the accurate three-dimensional model of ancient buildings is established with BIM technology, which provides new methods and ideas for the research and protection of ancient buildings. . 展开更多
关键词 Liu Ancestral Hall 3D Laser scanning Technology BIM Technology Point Cloud Processing
下载PDF
基于多重扫描速率法的α-Al_(2)O_(3)煅烧动力学研究
8
作者 邹婷 李中林 +4 位作者 王丁 吕凤程 张伟光 李义兵 蒋学先 《矿冶工程》 CAS 北大核心 2024年第2期106-111,共6页
以氢氧化铝粉体为原料,探究氢氧化铝煅烧为α-Al_(2)O_(3)过程中的相转变与微观组织变化,利用多重扫描速率法对其煅烧过程进行动力学模拟计算。结果表明,氢氧化铝煅烧为α-Al_(2)O_(3)的优化条件为:煅烧温度1200℃、煅烧时间2 h、升温速... 以氢氧化铝粉体为原料,探究氢氧化铝煅烧为α-Al_(2)O_(3)过程中的相转变与微观组织变化,利用多重扫描速率法对其煅烧过程进行动力学模拟计算。结果表明,氢氧化铝煅烧为α-Al_(2)O_(3)的优化条件为:煅烧温度1200℃、煅烧时间2 h、升温速率5℃/min。氢氧化铝煅烧过程出现3个吸热峰,对应3个失重阶段:第一阶段反应机理函数为G(α)=[(1-α)^(-1/3)-1]^2,反应平均活化能为91.16 kJ/mol,指前因子17.00×10^(9)~44.03×10^(9)min^(-1);第二阶段反应机理函数为G(α)=α~2,反应平均活化能为106.2 kJ/mol,指前因子7.70×10^(9)~18.60×10^(9)min^(-1);第三阶段反应机理函数为G(α)=α~(1/4),反应平均活化能为235.42 kJ/mol,指前因子39.94×10^(9)~50.79×10^(9)min^(-1)。 展开更多
关键词 氢氧化铝 氧化铝 煅烧 相变 α-Al_(2)O_(3) 热分析 动力学 多重扫描速率法
下载PDF
Multiphase cooperation for multilevel strain accommodation in a single-crystalline BiFeO_(3) thin film
9
作者 Wooseon Choi Bumsu Park +10 位作者 Jaejin Hwang Gyeongtak Han Sang-Hyeok Yang Hyeon Jun Lee Sung Su Lee Ji Young Jo Albina Y.Borisevich Hu Young Jeong Sang Ho Oh Jaekwang Lee Young-Min Kim 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期57-66,共10页
The functionalities and diverse metastable phases of multiferroic BiFeO_(3)(BFO)thin films depend on the misfit strain.Although mixed phase-induced strain relaxation in multiphase BFO thin films is well known,it is un... The functionalities and diverse metastable phases of multiferroic BiFeO_(3)(BFO)thin films depend on the misfit strain.Although mixed phase-induced strain relaxation in multiphase BFO thin films is well known,it is unclear whether a singlecrystalline BFO thin film can accommodate misfit strain without the involvement of its polymorphs.Thus,understanding the strain relaxation behavior is key to elucidating the lattice strain–property relationship.In this study,a correlative strain analysis based on dark-field inline electron holography(DIH)and quantitative scanning transmission electron microscopy(STEM)was performed to reveal the structural mechanism for strain accommodation of a single-crystalline BFO thin film.The nanoscale DIH strain analysis results indicated a random combination of multiple strain states that acted as a primary strain relief,forming irregularly strained nanodomains.The STEM-based bond length measurement of the corresponding strained nanodomains revealed a unique strain accommodation behavior achieved by a statistical combination of multiple modes of distorted structures on the unit-cell scale.The globally integrated strain for each nanodomain was estimated to be close to1.5%,irrespective of the nanoscale strain states,which was consistent with the fully strained BFO film on the SrTiO_(3) substrate.Density functional theory calculations suggested that strain accommodation by the combination of metastable phases was energetically favored compared to single-phase-mediated relaxation.This discovery allows a comprehensive understanding of strain accommodation behavior in ferroelectric oxide films,such as BFO,with various low-symmetry polymorphs. 展开更多
关键词 BiFeO_(3) scanning transmission electronmicroscopy electron holography multiferroic material strain mapping
下载PDF
Acoustical properties of a 3D printed honeycomb structure filled with nanofillers:Experimental analysis and optimization for emerging applications
10
作者 Jeyanthi Subramanian Vinoth kumar Selvaraj +3 位作者 Rohan Singh Ilangovan S Naresh Kakur Ruban Whenish 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第5期248-258,共11页
The novelty of this research lies in the successful fabrication of a 3D-printed honeycomb structure filled with nanofillers for acoustic properties,utilizing an impedance tube setup in accordance with ASTM standard E ... The novelty of this research lies in the successful fabrication of a 3D-printed honeycomb structure filled with nanofillers for acoustic properties,utilizing an impedance tube setup in accordance with ASTM standard E 1050-12.The Creality Ender-3,a 3D printer,was used for printing the honeycomb structures,and polylactic acid(PLA)material was employed for their construction.The organic,inorganic,and polymeric compounds within the composites were identified using fourier transformation infrared(FTIR)spectroscopy.The structure and homogeneity of the samples were examined using a field emission scanning electron microscope(FESEM).To determine the sound absorption coefficient of the 3D printed honeycomb structure,numerous samples were systematically developed using central composite design(CCD)and analysed using response surface methodology(RSM).The RSM mathematical model was established to predict the optimum values of each factor and noise reduction coefficient(NRC).The optimum values for an NRC of 0.377 were found to be 1.116 wt% carbon black,1.025 wt% aluminium powder,and 3.151 mm distance between parallel edges.Overall,the results demonstrate that a 3Dprinted honeycomb structure filled with nanofillers is an excellent material that can be utilized in various fields,including defence and aviation,where lightweight and acoustic properties are of great importance. 展开更多
关键词 3D printing Honeycomb structure ACOUSTICS Field emission scanning electron microscope Response surface methodology
下载PDF
Enhanced Electrical Properties of Bi_(2−x)Sb_(x)Te_(3) Nanoflake Thin Films Through Interface Engineering
11
作者 Xudong Wu Junjie Ding +8 位作者 Wenjun Cui Weixiao Lin Zefan Xue Zhi Yang Jiahui Liu Xiaolei Nie Wanting Zhu Gustaaf Van Tendeloo Xiahan Sang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第6期359-366,共8页
The structure–property relationship at interfaces is difficult to probe for thermoelectric materials with a complex interfacial microstructure.Designing thermoelectric materials with a simple,structurally-uniform int... The structure–property relationship at interfaces is difficult to probe for thermoelectric materials with a complex interfacial microstructure.Designing thermoelectric materials with a simple,structurally-uniform interface provides a facile way to understand how these interfaces influence the transport properties.Here,we synthesized Bi_(2−x)Sb_(x)Te_(3)(x=0,0.1,0.2,0.4)nanoflakes using a hydrothermal method,and prepared Bi_(2−x)Sb_(x)Te_(3) thin films with predominantly(0001)interfaces by stacking the nanoflakes through spin coating.The influence of the annealing temperature and Sb content on the(0001)interface structure was systematically investigated at atomic scale using aberration-corrected scanning transmission electron microscopy.Annealing and Sb doping facilitate atom diffusion and migration between adjacent nanoflakes along the(0001)interface.As such it enhances interfacial connectivity and improves the electrical transport properties.Interfac reactions create new interfaces that increase the scattering and the Seebeck coefficient.Due to the simultaneous optimization of electrical conductivity and Seebeck coefficient,the maximum power factor of the Bi_(1.8)Sb_(0.2)Te_(3) nanoflake films reaches 1.72 mW m^(−1)K^(−2),which is 43%higher than that of a pure Bi_(2)Te_(3) thin film. 展开更多
关键词 Bi_(2)Te_(3) nanoflakes interface engineering scanning transmission electron microscopy thermoelectric thin film
下载PDF
Algorithm and System of Scanning Color 3D Objects 被引量:1
12
作者 许智钦 孙长库 郑义忠 《Transactions of Tianjin University》 EI CAS 2002年第2期134-138,共5页
This paper presents a complete system for scanning the geometry and texture of a large 3D object, then the automatic registration is performed to obtain a whole realistic 3D model. This system is composed of one line ... This paper presents a complete system for scanning the geometry and texture of a large 3D object, then the automatic registration is performed to obtain a whole realistic 3D model. This system is composed of one line strip laser and one color CCD camera. The scanned object is pictured twice by a color CCD camera. First, the texture of the scanned object is taken by a color CCD camera. Then the 3D information of the scanned object is obtained from laser plane equations. This paper presents a practical way to implement the three dimensional measuring method and the automatic registration of a large 3D object and a pretty good result is obtained after experiment verification. 展开更多
关键词 D measurement color 3D object laser scanning surface construction
下载PDF
Scan Worx人体3D测量解决方案及其应用 被引量:1
13
作者 黄丽 施亦东 陈衍夏 《皮革科学与工程》 CAS 2007年第2期56-59,共4页
介绍了来自德国Vitronic公司的3D人体测量系统ScanWorx的系统组成、测量原理和应用功能,并对目前服装企业的应用状况提出了建议。
关键词 scan Worx 3D测量 人体扫描
下载PDF
急性缺血性脑卒中临床诊断中磁共振3D-pcASL成像技术的应用及临床价值 被引量:5
14
作者 赵福香 李彩霞 +1 位作者 徐焱 金艳 《临床医学研究与实践》 2020年第28期113-115,共3页
目的探讨急性缺血性脑卒中临床诊断中磁共振三维假连续式动脉自旋标记(3D-pcASL)成像技术的应用及临床价值。方法选取我院2019年2月至2020年1月收治的32例急性缺血性脑卒中患者作为研究对象。患者均行MRI、DWI及3D-pcASL检查,并测量溶... 目的探讨急性缺血性脑卒中临床诊断中磁共振三维假连续式动脉自旋标记(3D-pcASL)成像技术的应用及临床价值。方法选取我院2019年2月至2020年1月收治的32例急性缺血性脑卒中患者作为研究对象。患者均行MRI、DWI及3D-pcASL检查,并测量溶栓治疗前、后半暗带区脑血流量(CBF)。结果治疗前,32例急性缺血性脑卒中患者DWI、3D-pcASL图像分别显示为高信号和低灌注;32例患者3D-pcASL图像的低灌注区域范围明显大于DWI图像。治疗后,30例患者梗塞区呈高灌注改变,CBF值明显增大,周围半暗带出现匍匐走行的条、团块状高灌注信号;半暗带ROI的CBF值为(63.99±8.69)mL/(100 g·min),明显高于治疗前的(13.84±1.62)mL/(100 g·min)(P<0.05)。1例异常特高灌注患者为卒中后出血改变;1例患者治疗前、后均呈低灌注区,面积和CBF值无明显改变。结论 3D-pcASL成像技术是一种安全无创的脑血流检查技术,有利于及时指导急性缺血性脑卒中患者的治疗并判断预后,其客观影像信息对临床精准治疗具有显著价值。 展开更多
关键词 急性缺血性脑卒中 磁共振 3d-pcasl成像技术
下载PDF
铝合金喷涂Y_(2)O_(3)和Ni混合粉扫描电子束表面合金化的研究
15
作者 王荣 姜红飞 +2 位作者 魏德强 孟城功 王启超 《热加工工艺》 北大核心 2023年第24期146-151,共6页
扫描电子束表面合金化技术可改善铝合金表面性能。研究采用等离子热喷涂技术将不同含量的Y_(2)O_(3)与Ni混合粉末涂覆到6061铝合金表面,利用扫描电子束进行表面合金化处理。研究了表面合金化后强化层的组织形态、相结构和硬度的变化规律... 扫描电子束表面合金化技术可改善铝合金表面性能。研究采用等离子热喷涂技术将不同含量的Y_(2)O_(3)与Ni混合粉末涂覆到6061铝合金表面,利用扫描电子束进行表面合金化处理。研究了表面合金化后强化层的组织形态、相结构和硬度的变化规律,探讨了稀土Y_(2)O_(3)含量与电子束工艺参数对强化层组织和性能的影响。结果表明,电子束表面合金化处理,其表面可分为合金化区、热影响区和基体区。合金化区的显微组织主要由YAl_(3)、AlNiY和Ni_(17)Y_(2)等相组成,最高硬度为396 HV0.2,是基体的6倍;热影响区主要由α-Al固溶体和Ni-Al化合物相组成,最高硬度为260 HV0.2,是基体的4倍;基体的相结构主要为α-Al和Mg_(2)Si强化相组成。随着稀土Y_(2)O_(3)含量的增加,合金层组织晶粒得到细化,硬度得到提升。稀土Y_(2)O_(3)含量为5%,组织细化程度与硬度提升最明显。强化层显微硬度随束流的增加先增加后减少,随移动速度的增加而减少,当电子束束流为10 mA、移动速度为10 mm/s,强化层组织晶粒高度细化,硬度提升显著。 展开更多
关键词 扫描电子束 Y_(2)O_(3) 铝合金 合金化
下载PDF
3D-pCASL成像技术对卒中后broca失语症的应用研究 被引量:1
16
作者 王金言 席艳玲 王云玲 《中国CT和MRI杂志》 2022年第4期4-6,共3页
目的运用磁共振3D-pCASL脑灌注成像技术分析卒中后broca失语症患者语言功能区的脑血流量变化,进一步阐明失语症的发生机制。方法选择就诊于我院2020年10月至2021年6月间的、首次发生缺血性卒中后失语症病例20例,其中Broca失语14例,感觉... 目的运用磁共振3D-pCASL脑灌注成像技术分析卒中后broca失语症患者语言功能区的脑血流量变化,进一步阐明失语症的发生机制。方法选择就诊于我院2020年10月至2021年6月间的、首次发生缺血性卒中后失语症病例20例,其中Broca失语14例,感觉性失语6例,纳入病例组;选择健康志愿者20例,作为对照组,两组均行头颅MRI平扫及3D-pCASL成像扫描,将所获图像进行后处理,获得并比较两组间脑血流量。结果病例组运动性失语患者Broca区CBF值较对侧镜像区域减低(t=-11.18,P=0.00),差异有统计学意义(P<0.01);病例组感觉性失语Wernicke区CBF值较对侧镜像区减低(t=-6.24,P=0.00),差异具有统计学意义(P<0.01);病例组左侧Broca区、Wernicke区CBF值与正常组CBF值比较(t=-13.39,P=0.00),差异有统计学意义。结论失语的发生机制与卒中后失语患者语言功能区出现低灌注有较大的相关性。3D-pc ASL成像技术能够为卒中后运动性失语患者提供影像诊断依据,为临床诊疗及康复训练提供一定理论指导。 展开更多
关键词 脑卒中 BROCA失语 感觉性失语 三维准连续动脉自旋标记(3d-pcasl)
下载PDF
Monitoring slope deformation using a 3-D laser image scanning system: a case study 被引量:10
17
作者 YUE Depeng WANG Jiping +2 位作者 ZHOU Jinxing CHEN Xiaoxue REN Huijun 《Mining Science and Technology》 EI CAS 2010年第6期898-903,共6页
An ILRIS-36D 3-D laser image scanning system was used to monitor the Anjialing strip mine slope on Pingshuo in Shanxi province. The basic working principles, performance indexes, features and data collection and proce... An ILRIS-36D 3-D laser image scanning system was used to monitor the Anjialing strip mine slope on Pingshuo in Shanxi province. The basic working principles, performance indexes, features and data collection and processing methods are illus-trated. The point cloud results are analyzed in detail. The rescale range analysis method was used to analyze the deformation char-acteristics of the slope. The results show that the trend of slope displacement is stable and that the degree of landslide danger is low. This work indicates that 3-D laser image scanning can supply multi-parameter, high precision real time data over long distances. These data can be used to study the distortion of the slope quickly and accurately. 展开更多
关键词 3-D laser image scanning system ILRIS-36D -distortion SLOPE MONITOR
下载PDF
磁共振3D-pCASL成像技术在急性缺血性脑卒中临床诊断中的应用价值 被引量:10
18
作者 蒋代彬 杨清 +1 位作者 张国靖 李兰 《川北医学院学报》 CAS 2019年第4期437-440,共4页
目的:探讨磁共振三维准连续动脉自旋标记(3D-pCASL)成像技术在急性缺血性脑卒中患者中临床诊断中的应用价值。方法:选择61例急性缺血性脑卒中患者,设为观察组;选择同期治疗的59例非急性缺血性脑卒中患者,设为对照组。两组均在完成常规... 目的:探讨磁共振三维准连续动脉自旋标记(3D-pCASL)成像技术在急性缺血性脑卒中患者中临床诊断中的应用价值。方法:选择61例急性缺血性脑卒中患者,设为观察组;选择同期治疗的59例非急性缺血性脑卒中患者,设为对照组。两组均在完成常规磁共振弥散加权成像(DWI)及3D-pCASL检查;测量病灶及对侧镜像区域脑组织脑血流量(CBF);绘制ROC曲线,分析不同检查方法诊断效能。结果: 61例急性缺血性脑卒中患者最终均得到确诊,患者经3D-pCASL成像技术检测确诊60例,诊断符合率为98.36%( P >0.05);DWI检查确诊58例,诊断符合率95.08%( P >0.05);观察组患者健侧CBF水平与对照组比较,差异无统计学意义( P >0.05);观察组患者患侧CBF水平低于对照组( P <0.05);ROC曲线结果显示:单一DWI、3D-pCASL检查在急性缺血性脑卒中患者中的诊断特异性、敏感性均无统计学意义( P >0.05);DWI及3D-pCASL联合检查在急性缺血性脑卒中患者中的诊断特异性、敏感性,高于单一DWI、3D-pCASL检查( P <0.05)。结论:将3D-pCASL成像技术用于急性缺血性脑卒中患者中效果理想,能实现脑血流量的可视化,弥补传统DWI存在的弊端,为临床诊疗提供可靠的依据和参考。 展开更多
关键词 磁共振三维准连续动脉自旋标记(3d-pcasl) 成像技术 急性缺血性脑卒中 磁共振弥散加权成像
下载PDF
3D cavity detection technique and its application based on cavity auto scanning laser system 被引量:3
19
作者 刘希灵 李夕兵 +2 位作者 李发本 赵国彦 秦豫辉 《Journal of Central South University of Technology》 EI 2008年第2期285-288,共4页
Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. Th... Ground constructions and mines are severely threatened by ones. Safe and precise cavity detection is vital for reasonable cavity underground cavities especially those unsafe or inaccessible evaluation and disposal. The conventional cavity detection methods and their limitation were analyzed. Those methods cannot form 3D model of underground cavity which is used for instructing the cavity disposal; and their precisions in detection are always greatly affected by the geological circumstance. The importance of 3D cavity detection in metal mine for safe exploitation was pointed out; and the 3D cavity laser detection method and its principle were introduced. A cavity auto scanning laser system was recommended to actualize the cavity 3D detection after comparing with the other laser detection systems. Four boreholes were chosen to verify the validity of the cavity auto scanning laser system. The results show that the cavity auto scanning laser system is very suitable for underground 3D cavity detection, especially for those inaccessible ones. 展开更多
关键词 cavity detection 3D laser detection cavity auto scanning laser system
下载PDF
Experimental Research on Effects of Process Parameters on Servo Scanning 3D Micro Electrical Discharge Machining 被引量:3
20
作者 TONG Hao LI Yong HU Manhong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第1期114-121,共8页
Servo scanning 3D micro electrical discharge machining (3D SSMEDM) is a novel and effective method in fabricating complex 3D micro structures with high aspect ratio on conducting materials. In 3D SSMEDM process, the a... Servo scanning 3D micro electrical discharge machining (3D SSMEDM) is a novel and effective method in fabricating complex 3D micro structures with high aspect ratio on conducting materials. In 3D SSMEDM process, the axial wear of tool electrode can be compensated automatically by servo-keeping discharge gap, instead of the traditional methods that depend on experiential models or intermittent compensation. However, the effects of process parameters on 3D SSMEDM have not been reported up until now. In this study, the emphasis is laid on the effects of pulse duration, peak current, machining polarity, track style, track overlap, and scanning velocity on the 3D SSMEDM performances of machining efficiency, processing status, and surface accuracy. A series of experiments were carried out by machining a micro-rectangle cavity (900 μm×600 μm) on doped silicon. The experimental results were obtained as follows. Peak current plays a main role in machining efficiency and surface accuracy. Pulse duration affects obviously the stability of discharge state. The material removal rate of cathode processing is about 3/5 of that of anode processing. Compared with direction-parallel path, contour-parallel path is better in counteracting the lateral wear of tool electrode end. Scanning velocity should be selected moderately to avoid electric arc and short. Track overlap should be slightly less than the radius of tool electrode. In addition, a typical 3D micro structure of eye shape was machined based on the optimized process parameters. These results are beneficial to improve machining stability, accuracy, and efficiency in 3D SSMEDM. 展开更多
关键词 micro electrical discharge machining(micro EDM) servo scanning machining 3D micro-structure process parameter
下载PDF
上一页 1 2 29 下一页 到第
使用帮助 返回顶部