In this article, a Bi4π counting method comprised of Bi4πcounter and a new fundamental measurement method was described, which can measures rather more radionuclides and can achieve accuracy of 0.03% to 0.06% (1σ),...In this article, a Bi4π counting method comprised of Bi4πcounter and a new fundamental measurement method was described, which can measures rather more radionuclides and can achieve accuracy of 0.03% to 0.06% (1σ), in principle. Thecorrectness of this method is demonstrated by measurements of 60Co sources which results of activities compared with 47πβ-γ coincident method are in agreement within the measurement errors, and it is readily achieved to accuracy of 0.2%. Finally, the range of the applications for this Bi4π counting method among one hundred or more important radionuclides is also discussed.展开更多
A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the...A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the concentration of protein.The range of Beer's law was 1-5 ug/ml and the Sandell's sensitivity was 0.0087 ug/cm^2.展开更多
An arachidic acid/poly (3, 4-ethylene dioxythiophene) (AA/PEDOT) multilayer Langmuir-Blodgett (LB) film was prepared by a modified LB film method. The theories were utilized to explain the effects between HCl mo...An arachidic acid/poly (3, 4-ethylene dioxythiophene) (AA/PEDOT) multilayer Langmuir-Blodgett (LB) film was prepared by a modified LB film method. The theories were utilized to explain the effects between HCl molecule and LB film. The gas sensitivity mechanism of poly (3, 4-ethylene dioxythiophene) (PEDOT) multilayer film can be explained by the charge transfer between p system of PEDOT and oxidization HCl system. The gas sensitivity of PEDOT LB film deposited interdigital electrode to HCl was tested. The results showed that film thickness, treating temperature, deposition speed had different influence on film gas sensitivity. The AA/PEDOT film deposited device exhibited nonlinear behavior to HCl gas at lower concentration (20-60 ppm) and linear response behavior at higher gas concentration was observed. The time of the compound LB film of the AA/PEDOT responding to the 30 ppm HCl gas is about 20 seconds, which is far quicker than the time of the film to the PEDOTPRESS film(about 80 seconds). It is not higher film press to better film. When the film press attains 45 mNs/m, the sensitivity of the AA/PEDOT film on the contrary descends.展开更多
In this work,a Cu_(2)ZnSnS_(4)(CZTS)ingot is grown via a melting method,then cooled;the resulting molten stoichiomet-ric mixture is sealed off in a quartz ampoule under vacuum.The CZTS powder chemical composition anal...In this work,a Cu_(2)ZnSnS_(4)(CZTS)ingot is grown via a melting method,then cooled;the resulting molten stoichiomet-ric mixture is sealed off in a quartz ampoule under vacuum.The CZTS powder chemical composition analyses are determined us-ing energy dispersive spectroscopy,and revealing the slightly Cu-rich and Zn-poor character of the ingot.Powder X-ray diffrac-tion analysis reveals a crystalline structure with a kesterite phase formation,and a preferred orientation of(112)plane.The lat-tice constants of the a-and c-axes,calculated based on the XRD analyses,are a=5.40Åand c=10.84Å.Based on Hall measure-ments at room temperature,we find that the crystal exhibits p-type conductivity,with a high concentration of 1018 cm^(-3),a res-istivity of 1.7Ωcm,and a mobility of 10.69 cm^(2)V-1s-1.Activation energies are estimated based on an Arrhenius plot of conductiv-ity versus 1/T,for a temperature range of 80-350 K,measuring 35 and 160 meV in low-and high-temperature regimes,respect-ively,which is attributed to complex defects(2CuZn+SnZn)and antisite defects(CuZn),respectively.The observed scattering mech-anisms are attributed to ionized impurities and acoustic phonons at low and high temperatures,respectively.The extracted band-gap is 1.37 eV.展开更多
基金The Project Supported by National Natural Science Foundation of China
文摘In this article, a Bi4π counting method comprised of Bi4πcounter and a new fundamental measurement method was described, which can measures rather more radionuclides and can achieve accuracy of 0.03% to 0.06% (1σ), in principle. Thecorrectness of this method is demonstrated by measurements of 60Co sources which results of activities compared with 47πβ-γ coincident method are in agreement within the measurement errors, and it is readily achieved to accuracy of 0.2%. Finally, the range of the applications for this Bi4π counting method among one hundred or more important radionuclides is also discussed.
文摘A new dye-staining method for protein assay is described.The reaction between TPPS_4 and protein molecule causes a shift in the absorption of TPPS_4 from 435 nm to 488nm.The absorbance at 488 nm is proportional to the concentration of protein.The range of Beer's law was 1-5 ug/ml and the Sandell's sensitivity was 0.0087 ug/cm^2.
基金Funded by the National Natural Science Foundation of China (No.60372002)
文摘An arachidic acid/poly (3, 4-ethylene dioxythiophene) (AA/PEDOT) multilayer Langmuir-Blodgett (LB) film was prepared by a modified LB film method. The theories were utilized to explain the effects between HCl molecule and LB film. The gas sensitivity mechanism of poly (3, 4-ethylene dioxythiophene) (PEDOT) multilayer film can be explained by the charge transfer between p system of PEDOT and oxidization HCl system. The gas sensitivity of PEDOT LB film deposited interdigital electrode to HCl was tested. The results showed that film thickness, treating temperature, deposition speed had different influence on film gas sensitivity. The AA/PEDOT film deposited device exhibited nonlinear behavior to HCl gas at lower concentration (20-60 ppm) and linear response behavior at higher gas concentration was observed. The time of the compound LB film of the AA/PEDOT responding to the 30 ppm HCl gas is about 20 seconds, which is far quicker than the time of the film to the PEDOTPRESS film(about 80 seconds). It is not higher film press to better film. When the film press attains 45 mNs/m, the sensitivity of the AA/PEDOT film on the contrary descends.
文摘In this work,a Cu_(2)ZnSnS_(4)(CZTS)ingot is grown via a melting method,then cooled;the resulting molten stoichiomet-ric mixture is sealed off in a quartz ampoule under vacuum.The CZTS powder chemical composition analyses are determined us-ing energy dispersive spectroscopy,and revealing the slightly Cu-rich and Zn-poor character of the ingot.Powder X-ray diffrac-tion analysis reveals a crystalline structure with a kesterite phase formation,and a preferred orientation of(112)plane.The lat-tice constants of the a-and c-axes,calculated based on the XRD analyses,are a=5.40Åand c=10.84Å.Based on Hall measure-ments at room temperature,we find that the crystal exhibits p-type conductivity,with a high concentration of 1018 cm^(-3),a res-istivity of 1.7Ωcm,and a mobility of 10.69 cm^(2)V-1s-1.Activation energies are estimated based on an Arrhenius plot of conductiv-ity versus 1/T,for a temperature range of 80-350 K,measuring 35 and 160 meV in low-and high-temperature regimes,respect-ively,which is attributed to complex defects(2CuZn+SnZn)and antisite defects(CuZn),respectively.The observed scattering mech-anisms are attributed to ionized impurities and acoustic phonons at low and high temperatures,respectively.The extracted band-gap is 1.37 eV.