A colorimetric method for the direct determination of hydrogen peroxide in aqueous solution is described. H2O2 stoichiometrically converts 4-nitrophenyl boronic acid or 4-nitrophenyl boronic acid pinacol ester into 4-...A colorimetric method for the direct determination of hydrogen peroxide in aqueous solution is described. H2O2 stoichiometrically converts 4-nitrophenyl boronic acid or 4-nitrophenyl boronic acid pinacol ester into 4-nitrophenol, which can be quantified by measuring the absorption at 400 nm in neutral or basic media. The reactions proceed fast under basic conditions and complete in 2 minutes to at pH 11 and 80?C. The linear range for the colorimetric method extends beyond 1.0 to 40 μM H2O2, and the limit of detection is ~1.0 μM H2O2. This method offers a convenient and practical process for rapid determination of hydrogen peroxide in aqueous media. Compared to many other techniques in H2O2 detection, this process is a direct measurement of H2O2, and is relatively unaffected by the presence of various salts, metal ions and the chelator EDTA.展开更多
采用2-氯-4-碘-5-三氟代甲基吡啶为起始原料,与正丁基锂溶液反应制备5-三氟甲基-2-氯-4-吡啶硼酸。实验研究了合成反应过程几种反应条件对合成产率的影响情况,采用HPLC,FTIR,1 H NMR等方法对产品的纯度和结构进行了分析表征。实验结果表...采用2-氯-4-碘-5-三氟代甲基吡啶为起始原料,与正丁基锂溶液反应制备5-三氟甲基-2-氯-4-吡啶硼酸。实验研究了合成反应过程几种反应条件对合成产率的影响情况,采用HPLC,FTIR,1 H NMR等方法对产品的纯度和结构进行了分析表征。实验结果表明:当反应温度为-70℃,反应时间为2h,反应物料配比n(2-氯-4-碘-5-三氟代甲基吡啶)∶n(硼酸三丁酯)∶n(正丁基锂)为1.00∶1.20∶1.20,溶液pH值为9.0时,5-三氟甲基-2-氯-4-吡啶硼酸的收率为83.10%,纯度可达98.65%以上。展开更多
文摘A colorimetric method for the direct determination of hydrogen peroxide in aqueous solution is described. H2O2 stoichiometrically converts 4-nitrophenyl boronic acid or 4-nitrophenyl boronic acid pinacol ester into 4-nitrophenol, which can be quantified by measuring the absorption at 400 nm in neutral or basic media. The reactions proceed fast under basic conditions and complete in 2 minutes to at pH 11 and 80?C. The linear range for the colorimetric method extends beyond 1.0 to 40 μM H2O2, and the limit of detection is ~1.0 μM H2O2. This method offers a convenient and practical process for rapid determination of hydrogen peroxide in aqueous media. Compared to many other techniques in H2O2 detection, this process is a direct measurement of H2O2, and is relatively unaffected by the presence of various salts, metal ions and the chelator EDTA.
文摘采用2-氯-4-碘-5-三氟代甲基吡啶为起始原料,与正丁基锂溶液反应制备5-三氟甲基-2-氯-4-吡啶硼酸。实验研究了合成反应过程几种反应条件对合成产率的影响情况,采用HPLC,FTIR,1 H NMR等方法对产品的纯度和结构进行了分析表征。实验结果表明:当反应温度为-70℃,反应时间为2h,反应物料配比n(2-氯-4-碘-5-三氟代甲基吡啶)∶n(硼酸三丁酯)∶n(正丁基锂)为1.00∶1.20∶1.20,溶液pH值为9.0时,5-三氟甲基-2-氯-4-吡啶硼酸的收率为83.10%,纯度可达98.65%以上。