AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, co...AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.展开更多
Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission wit...Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission within the respective intermanifold transitions of ^4F3/2→^4I9/2are investigated. The 946.0-nm line shifts toward the shorter wavelength and broadens. In addition, the threshold power and slope efficiency of the 946.0-nm laser line are quantified with temperature.The lower the temperature, the lower the threshold power is and the higher the slope efficiency of the 946.0-nm laser line is,thus the higher the laser output is. This phenomenon is attributed to the ion-phonon interaction and the thermal population in the ground state.展开更多
A quasi-continuous-wave intracavity frequency-doubled Nd:YAG laser which operates at 660 nm is studied. By using a flat-flat laser cavity, 2 Kr-lamps, KTP crystal and an acousto-optically Q-switch, 2-W output power at...A quasi-continuous-wave intracavity frequency-doubled Nd:YAG laser which operates at 660 nm is studied. By using a flat-flat laser cavity, 2 Kr-lamps, KTP crystal and an acousto-optically Q-switch, 2-W output power at 660 nm is obtained. The relationship between laser cavity length and output power is analyzed.展开更多
文摘AIM: To evaluate the outcome of laser iridotomy using532-nm Nd: YAG laser(PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy.METHODS: Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes underwent iridotomy using conventional combined laser method. The average settings of PASCAL were60 μm and 700-900 m W with a short duration of 0.01 s to reduce the total applied energy. The conventional laser was 50 μm and 700-900 m W for 0.1s. After photocoagulation with these laser, the Nd: YAG laser was added in each group. Endothelial cell counts of preiridotomy and 2mo after iridotomy were measured and compared.RESULTS: All eyes completed iridotomy successfully.The total energy used in the PASCAL group was 1.85 ±1.17 J. Compared to conventional laser 13.25 ±1.67 J, the energy used was very small due to the short exposure time of PASCAL. Endothelial cell counts were reduced by0.88% in the PASCAL group and 6.72% in the conventional laser group(P =0.044). The change in corneal endothelial cell counts before and after iridotomy was significant in conventional combined laser iridotomy group(P =0.004).CONCLUSION: Combined PASCAL and Nd:YAG laseriridotomy is an effective and safe technique in the dark brown irides of Asians. Furthermore, the short duration of exposure in PASCAL offers the advantages of reducing the total energy used and minimizing the corneal damage.
基金Project supported by Estahban Branch,Islamic Azad University
文摘Spectroscopic properties of flashlamp pumped Nd^3+:YAG laser are studied as a function of temperature in a range from-30℃ to 60℃. The spectral width and shift of quasi three-level 946.0-nm inter-Stark emission within the respective intermanifold transitions of ^4F3/2→^4I9/2are investigated. The 946.0-nm line shifts toward the shorter wavelength and broadens. In addition, the threshold power and slope efficiency of the 946.0-nm laser line are quantified with temperature.The lower the temperature, the lower the threshold power is and the higher the slope efficiency of the 946.0-nm laser line is,thus the higher the laser output is. This phenomenon is attributed to the ion-phonon interaction and the thermal population in the ground state.
文摘A quasi-continuous-wave intracavity frequency-doubled Nd:YAG laser which operates at 660 nm is studied. By using a flat-flat laser cavity, 2 Kr-lamps, KTP crystal and an acousto-optically Q-switch, 2-W output power at 660 nm is obtained. The relationship between laser cavity length and output power is analyzed.