The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose a...The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose and localize faults in the rectifier,this paper proposes a frequencydomain analysis-based fault diagnosis algorithm for the rectifier in AGPS.First,time-domain expressions and spectral characteristics of the output voltage of the TPTL-NPC inverter-based power supply are analyzed.Then,frequency-domain analysis-based fault diagnosis and frequency-domain analysis-based sub-fault diagnosis algorithms are proposed to diagnose open circuit(OC) faults of diode(s),which benefit from the analysis of harmonics magnitude and phase-angle of the output voltage.Only a fundamental period is needed to diagnose and localize exact faults,and a strong Variable-duration Fault Detection Method is proposed to identify acceptable ripple from OC faults.Detailed simulations and experimental results demonstrate the effectiveness,quickness,and robustness of the proposed algorithms,and the diagnosis algorithms proposed in this article provide a significant method for the fault diagnosis of other rectifiers and converters.展开更多
This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink powe...This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink power system toolbox is used to simulate the system. In the simulation model, as the most common harmonic source, 3-phase thyristor bridge rectifier circuit is constructed. The simulation results before and after the shunt active filter was switched to the system corresponding to different firing angles of the thyristors are presented and analyzed, which demonstrate the practicability and reliability of the proposed shunt active filter scheme.展开更多
基金supported by the National Key R&D Program of China(No.2017YFE0300104)National Natural Science Foundation of China(No.51821005)
文摘The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose and localize faults in the rectifier,this paper proposes a frequencydomain analysis-based fault diagnosis algorithm for the rectifier in AGPS.First,time-domain expressions and spectral characteristics of the output voltage of the TPTL-NPC inverter-based power supply are analyzed.Then,frequency-domain analysis-based fault diagnosis and frequency-domain analysis-based sub-fault diagnosis algorithms are proposed to diagnose open circuit(OC) faults of diode(s),which benefit from the analysis of harmonics magnitude and phase-angle of the output voltage.Only a fundamental period is needed to diagnose and localize exact faults,and a strong Variable-duration Fault Detection Method is proposed to identify acceptable ripple from OC faults.Detailed simulations and experimental results demonstrate the effectiveness,quickness,and robustness of the proposed algorithms,and the diagnosis algorithms proposed in this article provide a significant method for the fault diagnosis of other rectifiers and converters.
文摘This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink power system toolbox is used to simulate the system. In the simulation model, as the most common harmonic source, 3-phase thyristor bridge rectifier circuit is constructed. The simulation results before and after the shunt active filter was switched to the system corresponding to different firing angles of the thyristors are presented and analyzed, which demonstrate the practicability and reliability of the proposed shunt active filter scheme.