The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS ...The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units.展开更多
The PLC and upper computer are used in BOP control system of traditional thermal power plant to monitor the in-situ equipment. It is complicated and wastes labor and resources. It is difficult to maintain and manage t...The PLC and upper computer are used in BOP control system of traditional thermal power plant to monitor the in-situ equipment. It is complicated and wastes labor and resources. It is difficult to maintain and manage them. Beijing GuoDian ZhiShen Control Technology applied the homemade DCS (EDPF-NT System) to the integrated BOP control system of 600-MW supercritical power unit, which offers advantages in efficiency promotion, cost reduction and resource sharing. That also reflects the dominance of EDPF-NT System in performance, price, real-time DUP, network compatibility and communication. This article introduces the main characteristics, structure and configuration of EDPF-NT System, as well as the hierarchical operation, the multi-domain network structure and the private network router developed for Zhuanghe Power Plant.展开更多
The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration ...The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increases of the No.3 bearing pedestal and large vibration of the exciter rotor during its critical speed range. The vibration characteristics and the causes of faults and countermeasures were analyzed. Three applications for further illustration were given. The vibration fault identification method, control measures, and applications can provide a reference for vibration diagnoses and treatment of same type units.展开更多
文摘The problems including excessive flow of attemperating water for boiler, failure of butterfly valve at the outlet of circulating water pump, burnt-out of thyristor for excitation regulator, load variation rate of CCS not complying with the contract target, etc. occurred during start-up and debugging of two 600 MW generating units in Yangzhou No.2 Thermal Power Plant. Through analysis on these problems. the remedial measures were put forward, to which can be referred for similar units.
文摘The PLC and upper computer are used in BOP control system of traditional thermal power plant to monitor the in-situ equipment. It is complicated and wastes labor and resources. It is difficult to maintain and manage them. Beijing GuoDian ZhiShen Control Technology applied the homemade DCS (EDPF-NT System) to the integrated BOP control system of 600-MW supercritical power unit, which offers advantages in efficiency promotion, cost reduction and resource sharing. That also reflects the dominance of EDPF-NT System in performance, price, real-time DUP, network compatibility and communication. This article introduces the main characteristics, structure and configuration of EDPF-NT System, as well as the hierarchical operation, the multi-domain network structure and the private network router developed for Zhuanghe Power Plant.
文摘The layout features of unit shafting and their effects on vibration, as well as evaluation criteria, were introduced for a 1000-MW ultra-supercritical turbine-generator unit with Simens technology. Based on vibration diagnosis and treatment for more than 10 units, some typical vibration faults were summarized, such as the vibration fluctuation of the high pressure (HP) rotor, abnormal vibration increases of the No.3 bearing pedestal and large vibration of the exciter rotor during its critical speed range. The vibration characteristics and the causes of faults and countermeasures were analyzed. Three applications for further illustration were given. The vibration fault identification method, control measures, and applications can provide a reference for vibration diagnoses and treatment of same type units.