Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Result...Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs.展开更多
Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 202...Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 2022 to March 2023 were selected.All patients underwent both 64-slice spiral CT and digital subtraction angiography(DSA).DSA is considered the gold standard for diagnosis,so it was used to analyze the diagnostic performance of 64-slice spiral CT.Results:(1)The diagnostic results of digital subtraction angiography and 64-slice spiral CT was analyzed and compared with each other.The 64-slice spiral CT had an accuracy of 96.67%(29/30),a sensitivity 96.55%(28/29),and a specificity of 100.00%(1/1)in diagnosing coronary artery stenosis.(2)There was no significant difference between 64-slice spiral CT and digital subtraction angiography in the positive detection rate of anterior descending artery lesion,the positive detection rate of left main lesion,the positive detection rate of left circumflex artery lesion and the positive detection rate of right coronary artery lesion(P>0.05).(3)There was no significant difference between 64-slice spiral CT examination and DSA examination in identifying mild stenosis,moderate stenosis,and severe stenosis of coronary arteries(P>0.05).Conclusion:64-slice spiral CT examination can accurately determine the degree of occlusion of coronary arteries,which allows for the accurate diagnosis of coronary artery stenosis.展开更多
Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtap...Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtapapillary or macular area. The diagnosis is clinical and can be confirmed with the use of fluorescein or indocyanine angiography, optical coherence tomography, computed tomography or magnetic resonance imaging. Choroidal neovascularization or subretinal fluid, the main causes for vision loss, can be treated with laser therapy, photodynamic therapy or intravitreal antivascular endothelial growth factor therapy. We present a case of choroidal osteoma, showing the role of the high resolution 3D spiral computed tomography.展开更多
AIM To observe the effect of targeted therapy with 64-slice spiral computed tomography(CT) combined with cryoablation for liver cancer.METHODS A total of 124 patients(142 tumors) were enrolled into this study. Accordi...AIM To observe the effect of targeted therapy with 64-slice spiral computed tomography(CT) combined with cryoablation for liver cancer.METHODS A total of 124 patients(142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group(n = 56, 65 tumors) and 64-slice group(n = 8, 77 tumors). All patients were accepted and received targetedtherapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of ≥ 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [hepatic artery perfusion(HAp), portal vein perfusion(p Vp), and the hepatic arterial perfusion index(HAp I)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding.RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group(t = 11.445, p = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group(81.58%) was lower than that in the 64-slice group(92.86%)(χ2 = 5.707, p = 0.017). The HAp and HAp I of tumor tissues were lower at four weeks post-treatment than at pretreatment in both groups(all p < 0.05), and those in the 64-slice group were lower than that in the dualslice group(all p < 0.05). HAp and p Vp were lower and HAp I was higher in tumor adjacent tissues at post-treatment than at pre-treatment(all p < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks post-treatment(all p < 0.05). Moreover, pleural effusion and intraperitoneal hemorrhage occurred in patients in the dual-slice group, while no complications occurred in the 64-slice group(all p < 0.05). CONCLUSION64-slice spiral CT applied with cryoablation in targeted therapy for liver cancer can achieve a safe and effective freezing treatment, so it is worth being used.展开更多
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
文摘Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs.
文摘Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 2022 to March 2023 were selected.All patients underwent both 64-slice spiral CT and digital subtraction angiography(DSA).DSA is considered the gold standard for diagnosis,so it was used to analyze the diagnostic performance of 64-slice spiral CT.Results:(1)The diagnostic results of digital subtraction angiography and 64-slice spiral CT was analyzed and compared with each other.The 64-slice spiral CT had an accuracy of 96.67%(29/30),a sensitivity 96.55%(28/29),and a specificity of 100.00%(1/1)in diagnosing coronary artery stenosis.(2)There was no significant difference between 64-slice spiral CT and digital subtraction angiography in the positive detection rate of anterior descending artery lesion,the positive detection rate of left main lesion,the positive detection rate of left circumflex artery lesion and the positive detection rate of right coronary artery lesion(P>0.05).(3)There was no significant difference between 64-slice spiral CT examination and DSA examination in identifying mild stenosis,moderate stenosis,and severe stenosis of coronary arteries(P>0.05).Conclusion:64-slice spiral CT examination can accurately determine the degree of occlusion of coronary arteries,which allows for the accurate diagnosis of coronary artery stenosis.
文摘Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtapapillary or macular area. The diagnosis is clinical and can be confirmed with the use of fluorescein or indocyanine angiography, optical coherence tomography, computed tomography or magnetic resonance imaging. Choroidal neovascularization or subretinal fluid, the main causes for vision loss, can be treated with laser therapy, photodynamic therapy or intravitreal antivascular endothelial growth factor therapy. We present a case of choroidal osteoma, showing the role of the high resolution 3D spiral computed tomography.
基金Supported by Hebei Province Health Department of Scientific Research fund project,No.20110157
文摘AIM To observe the effect of targeted therapy with 64-slice spiral computed tomography(CT) combined with cryoablation for liver cancer.METHODS A total of 124 patients(142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group(n = 56, 65 tumors) and 64-slice group(n = 8, 77 tumors). All patients were accepted and received targetedtherapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of ≥ 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [hepatic artery perfusion(HAp), portal vein perfusion(p Vp), and the hepatic arterial perfusion index(HAp I)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding.RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group(t = 11.445, p = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group(81.58%) was lower than that in the 64-slice group(92.86%)(χ2 = 5.707, p = 0.017). The HAp and HAp I of tumor tissues were lower at four weeks post-treatment than at pretreatment in both groups(all p < 0.05), and those in the 64-slice group were lower than that in the dualslice group(all p < 0.05). HAp and p Vp were lower and HAp I was higher in tumor adjacent tissues at post-treatment than at pre-treatment(all p < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks post-treatment(all p < 0.05). Moreover, pleural effusion and intraperitoneal hemorrhage occurred in patients in the dual-slice group, while no complications occurred in the 64-slice group(all p < 0.05). CONCLUSION64-slice spiral CT applied with cryoablation in targeted therapy for liver cancer can achieve a safe and effective freezing treatment, so it is worth being used.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.