A GaN-based pin neutron detector with a 6LiF conversion layer was fabricated, and can be used to detect thermal neutrons. Measurement of the electrical characteristic of the GaN-based pin neutron detector showed that ...A GaN-based pin neutron detector with a 6LiF conversion layer was fabricated, and can be used to detect thermal neutrons. Measurement of the electrical characteristic of the GaN-based pin neutron detector showed that the reverse leakage current of the neutron detector was reduced significantly after deposition of a 6LiF conversion layer on the detector surface. The thermal neutrons used in this experiment were obtained from an 241Am-Be fast neutron source after being moderated by 100-mm-thick high-density polyethylene. The experimental results show that the detector with 16.9-μm thick 6LiF achieved a maximum neutron detection efficiency of 1.9% at a reverse bias of 0 V, which is less than the theoretical detection efficiency of 4.1% calculated for our GaN neutron detectors.展开更多
The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors wi...The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.展开更多
A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scinti...A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scintillator is about 0.65 mm.Its thermal neutron detection efficiency,gamma sensitivity and intrinsic spatial resolution can achieve around 50.0%,10 5and 0.18 mm(along X-axis) respectively.For the detector,air coupling position resolution is better than the silicone oil coupling.Some of the simulation results are compared with experimental results.They are in agreement.This work will be helpful for constructing neutron detector for high intensity powder diffractometer at Chinese spallation neutron source.展开更多
The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two ...The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61964001 and 61961001)the State Key Laboratory of Particle Detection and Electronics(Grant No.SKLPDE-KF-2019)+2 种基金the Natural Science Foundation of Jiangxi Province,China(Grant Nos.20192BAB207033 and 20181BAB202026)the Foundation of State Key Laboratory Breeding Base of Nuclear Resources and Environment(East China Institute of Technology)(Grant No.NRE1515)the Jiangxi Provincial Postdoctoral Science Foundation,China(Grant No.2018KY31).
文摘A GaN-based pin neutron detector with a 6LiF conversion layer was fabricated, and can be used to detect thermal neutrons. Measurement of the electrical characteristic of the GaN-based pin neutron detector showed that the reverse leakage current of the neutron detector was reduced significantly after deposition of a 6LiF conversion layer on the detector surface. The thermal neutrons used in this experiment were obtained from an 241Am-Be fast neutron source after being moderated by 100-mm-thick high-density polyethylene. The experimental results show that the detector with 16.9-μm thick 6LiF achieved a maximum neutron detection efficiency of 1.9% at a reverse bias of 0 V, which is less than the theoretical detection efficiency of 4.1% calculated for our GaN neutron detectors.
基金the National Natural Science Foundation of China(Grant Nos.11875273,U1832111,61964001,and 12275049)the Science Foundation of Guangdong Province of China(Grant No.2020B1515120025)+3 种基金the Neutron Physics Laboratory Funding of China Academy of Engineering Physics(Grant No.2018BC03)the General Project of Jiangxi Province Key Research and Development Program(Grant No.20212BBG73012)the Key Scientific Research Projects of Henan Higher Education Institutions(Grant Nos.23A490002 and 24A490001)the Engineering Research Center of Nuclear Technology Application(Grant No.HJSJYB2021-4)。
文摘The energy-resolved neutron imaging spectrometer(ERNI)will be installed in 2022 according to the spectrometer construction plan of the China Spallation Neutron Source(CSNS).The instrument requires neutron detectors with the coverage area of approximately 4 m^(2)in 5°-170°neutron diffraction angle.The neutron detection efficiency needs to be better than 40%at 1 A neutron wavelength.The spatial resolution should be better than 3 mm×50 mm in the horizontal and vertical directions respectively.We develop a one-dimensional scintillator neutron detector which is composed of the^(6)Li F/Zn S(Ag)scintillation screens,the wavelength-shifting fiber(WLSF)array,the silicon photomultipliers(Si PMs),and the self-designed application-specific integrated circuit(ASIC)readout electronics.The pixel size of the detector is designed as 3 mm×50 mm,and the neutron-sensitive area is 50 mm×200 mm.The performance of the detector prototype is measured using neutron beam 20#of the CSNS.The maximum counting rate of 247 k Hz,and the detection efficiency of63%at 1.59 A are obtained.The test results show that the performance of the detector fulfills the physical requirements of the ERNI under construction at the CSNS.
基金supported by the National Natural Science Foundation of China(Grant No.11175257)
文摘A simulation of the properties of the shifting scintillator neutron detector using 6LiF/ZnS(Ag) scintillation screens is performed.The simulation results show that the light attenuation length of standard BC704 scintillator is about 0.65 mm.Its thermal neutron detection efficiency,gamma sensitivity and intrinsic spatial resolution can achieve around 50.0%,10 5and 0.18 mm(along X-axis) respectively.For the detector,air coupling position resolution is better than the silicone oil coupling.Some of the simulation results are compared with experimental results.They are in agreement.This work will be helpful for constructing neutron detector for high intensity powder diffractometer at Chinese spallation neutron source.
基金Supported by National Natural Science Foundation of China(11175257)Key Laboratory of Neutron Detection and Electronics of Dongguan Municipality
文摘The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.