A lab-scale anaerobic-anoxic-oxic (A2O) process used to treat a synthetic brewage wastewater was investigated. The objectives of the study were to identify the existence of denitrifying phosphorus removing bacteria (D...A lab-scale anaerobic-anoxic-oxic (A2O) process used to treat a synthetic brewage wastewater was investigated. The objectives of the study were to identify the existence of denitrifying phosphorus removing bacteria (DPB), evaluate the contribution of DPB to biological nutrient removal and enhance the denitrifying phosphorus removal in A2O bioreactors. Sludge analysis confirmed that the average anoxic P uptake accounted for approximately 70% the total amount of P uptake, and the ratio of anoxic P uptake rate to aerobic P uptake rate was 69%. In addition, nitrate concentration in the anoxic phase and different organic substrate introduced into the anaerobic phase had significant effect on the anoxic P uptake. Compared with conventional A2O processes, good removal efficiencies of COD, phosphorus, ammonia and total nitrogen (92.3%, 95.5%, 96% and 79.5%, respectively) could be achieved in the anoxic P uptake system, and aeration energy consumption was saved 25%. By controlling the nitrate recirculation flow in the anoxic zone, anoxic P uptake could be enhanced, which solved the competition for organic substrates among poly-P organisms and denitrifiers successfully under the COD limiting conditions. Therefore, in wastewater treatment plants the control system should be applied according to the practical situation to optimize the operation.展开更多
A bench-scale anaerobic/anoxic/aerobic process-biological aerated filter (A^2/O-BAF) combined system was carded out to treat wastewater with lower C/N and C/P ratios. The A^2/O process was operated in a short aerobi...A bench-scale anaerobic/anoxic/aerobic process-biological aerated filter (A^2/O-BAF) combined system was carded out to treat wastewater with lower C/N and C/P ratios. The A^2/O process was operated in a short aerobic sludge retention time (SRT) for organic pollutants and phosphorus removal, and denitrification. The subsequent BAF process was mainly used for nitrification. The BAF effluent was partially returned to anoxic zone of the A^2/O process to provide electron acceptors for denitrification and anoxic P uptake. This unique system formed an environment for reproducing the denitdfying phosphate-accumulating organisms (DPAOs). The ratio of DPAOs to phosphorus accumulating organisms (PAOs) could be maintained at 28% by optimizing the organic loads in the anaerobic zone and the nitrate loads into the anoxic zone in the A^2/O process. The aerobic phosphorus over-uptake and discharge of excess activated sludge was the main mechanism of phosphorus removal in the combined system. The aerobic SRT of the A^2/O process should meet the demands for the development of aerobic PAOs and the restraint on the nitrifiers growth, and the contact time in the aerobic zone of the A^2/O process should be longer than 30 min, which ensured efficient phosphorus removal in the combined system. The adequate BAF effluent return rates should be controlled with 1--4 mg/L nitrate nitrogen in the anoxic zone effluent of A^2/O process to achieve the optimal nitrogen and phosphorus removal efficiencies.展开更多
Objective This study was conducted to optimize the operational parameters of anaerobic-anoxic-oxic (A^2/O) processes to reduce the toxicity of municipal wastewater and evaluate its ability to reduce toxicity. Method...Objective This study was conducted to optimize the operational parameters of anaerobic-anoxic-oxic (A^2/O) processes to reduce the toxicity of municipal wastewater and evaluate its ability to reduce toxicity. Methods A luminescent bacterium toxicity bioassay was employed to assess the toxicity of influent and effluent of each reactor in the A2/O system. Results The optimum operational parameters for toxicity reduction were as follows: anaerobic hydraulic retention time (HRT) = 2.8 h, anoxic HRT = 2.8 h, aerobic HRT = 6.9 h, sludge retention time (SRT) = 15 days and internal recycle ratio (IRR) = 100%. An important toxicity reduction (%) was observed in the optimized A2/O process, even when the toluene concentration of the influent was 120.7 mg·L^-1. Conclusions The toxicity of municipal wastewater was reduced significantly during the A^2/O process. A^2/O process can be used for toxicity reduction of municipal wastewater under toxic-shock loading.展开更多
In recent years, the beer industry is a biological food industry that consumes a lot of water, and it has developed rapidly in China. The sewage discharged from the mass production of beer poses a huge threat to the e...In recent years, the beer industry is a biological food industry that consumes a lot of water, and it has developed rapidly in China. The sewage discharged from the mass production of beer poses a huge threat to the environment. In order to evaluate and better solve the possible environmental impacts of beer treatment engineering projects, a brewery project in Foshan City is taken as an example to investigate the water pollution generation links of the engineering process including surface water and groundwater. According to the relevant technical methods and standards, water pollution factors are screened, and concentration and discharge are monitored. Through comprehensive analysis, predictive evaluation is obtained. It is confirmed that the project meets the requirements of national laws and regulations and environmental protection standards.展开更多
基金Supported by Key Technology Research and Development Program of the Tenthfive-year plan (2001BA610A-09), the NationalNatural Science Foundation of China (No. 50478040) and 863 Hi-Technology Research and Development Program of China(No.2004AA601020)
文摘A lab-scale anaerobic-anoxic-oxic (A2O) process used to treat a synthetic brewage wastewater was investigated. The objectives of the study were to identify the existence of denitrifying phosphorus removing bacteria (DPB), evaluate the contribution of DPB to biological nutrient removal and enhance the denitrifying phosphorus removal in A2O bioreactors. Sludge analysis confirmed that the average anoxic P uptake accounted for approximately 70% the total amount of P uptake, and the ratio of anoxic P uptake rate to aerobic P uptake rate was 69%. In addition, nitrate concentration in the anoxic phase and different organic substrate introduced into the anaerobic phase had significant effect on the anoxic P uptake. Compared with conventional A2O processes, good removal efficiencies of COD, phosphorus, ammonia and total nitrogen (92.3%, 95.5%, 96% and 79.5%, respectively) could be achieved in the anoxic P uptake system, and aeration energy consumption was saved 25%. By controlling the nitrate recirculation flow in the anoxic zone, anoxic P uptake could be enhanced, which solved the competition for organic substrates among poly-P organisms and denitrifiers successfully under the COD limiting conditions. Therefore, in wastewater treatment plants the control system should be applied according to the practical situation to optimize the operation.
文摘A bench-scale anaerobic/anoxic/aerobic process-biological aerated filter (A^2/O-BAF) combined system was carded out to treat wastewater with lower C/N and C/P ratios. The A^2/O process was operated in a short aerobic sludge retention time (SRT) for organic pollutants and phosphorus removal, and denitrification. The subsequent BAF process was mainly used for nitrification. The BAF effluent was partially returned to anoxic zone of the A^2/O process to provide electron acceptors for denitrification and anoxic P uptake. This unique system formed an environment for reproducing the denitdfying phosphate-accumulating organisms (DPAOs). The ratio of DPAOs to phosphorus accumulating organisms (PAOs) could be maintained at 28% by optimizing the organic loads in the anaerobic zone and the nitrate loads into the anoxic zone in the A^2/O process. The aerobic phosphorus over-uptake and discharge of excess activated sludge was the main mechanism of phosphorus removal in the combined system. The aerobic SRT of the A^2/O process should meet the demands for the development of aerobic PAOs and the restraint on the nitrifiers growth, and the contact time in the aerobic zone of the A^2/O process should be longer than 30 min, which ensured efficient phosphorus removal in the combined system. The adequate BAF effluent return rates should be controlled with 1--4 mg/L nitrate nitrogen in the anoxic zone effluent of A^2/O process to achieve the optimal nitrogen and phosphorus removal efficiencies.
基金supported by the National Science Foundation Project grants of China(No.50878165,No.21007010)the Program for New Century Excellent Talents in University(NCET-08-0403)+4 种基金the Research Fund for the Doctoral Program of Higher Education of China(No.20090075120007)the Shanghai Committee of Science and Technology,China(No.09230500200)the Fundamental Research Funds for the Central Universities of China(No.10D11308)the Key Special Program on the S&T for the Pollution Control and Treatment of Water Bodies(No. 2008ZX07316-003)the Shanghai Leading Academic Discipline Project (No.B604)
文摘Objective This study was conducted to optimize the operational parameters of anaerobic-anoxic-oxic (A^2/O) processes to reduce the toxicity of municipal wastewater and evaluate its ability to reduce toxicity. Methods A luminescent bacterium toxicity bioassay was employed to assess the toxicity of influent and effluent of each reactor in the A2/O system. Results The optimum operational parameters for toxicity reduction were as follows: anaerobic hydraulic retention time (HRT) = 2.8 h, anoxic HRT = 2.8 h, aerobic HRT = 6.9 h, sludge retention time (SRT) = 15 days and internal recycle ratio (IRR) = 100%. An important toxicity reduction (%) was observed in the optimized A2/O process, even when the toluene concentration of the influent was 120.7 mg·L^-1. Conclusions The toxicity of municipal wastewater was reduced significantly during the A^2/O process. A^2/O process can be used for toxicity reduction of municipal wastewater under toxic-shock loading.
基金Supported by Key Fields of Universities in Guangdong Province (Science and Technology Service for Rural Revitalization)(2021ZDZX4023)2021 Undergraduate Teaching Quality and Teaching Construction Project of Guangdong Province (Guangdong Education Gao Han [2021] 29)+1 种基金Zhaoqing University Quality Engineering and Teaching Reform Project (zlgc 201931)Zhaoqing University Students’Innovation and Entrepreneurship Training Program in 2022 (X 202210580130)。
文摘In recent years, the beer industry is a biological food industry that consumes a lot of water, and it has developed rapidly in China. The sewage discharged from the mass production of beer poses a huge threat to the environment. In order to evaluate and better solve the possible environmental impacts of beer treatment engineering projects, a brewery project in Foshan City is taken as an example to investigate the water pollution generation links of the engineering process including surface water and groundwater. According to the relevant technical methods and standards, water pollution factors are screened, and concentration and discharge are monitored. Through comprehensive analysis, predictive evaluation is obtained. It is confirmed that the project meets the requirements of national laws and regulations and environmental protection standards.