Temperature-time curves were measured for the air cooling and laminar cooling of a steel plate.Convective heat transfer coefficients of steel plate and air as well as steel plate and laminar cooling water were compute...Temperature-time curves were measured for the air cooling and laminar cooling of a steel plate.Convective heat transfer coefficients of steel plate and air as well as steel plate and laminar cooling water were computed inversely. Therefore,the temperature field in the single-face quenching process of a steel pipe was simulated using ABAQUS finite element softw are,and the relationships betw een the temperatures and quenching time at different positions of the steel pipe were obtained. In addition,the relationships betw een the cooling rates and quenching time,as w ell as betw een cooling rates and temperatures,were obtained. The simulation quickly produced accurate results,and it can be used to optimize the quenching process. In addition,the results provide a basis for rationally designing the composition of a single-face quenching steel pipe.展开更多
文摘Temperature-time curves were measured for the air cooling and laminar cooling of a steel plate.Convective heat transfer coefficients of steel plate and air as well as steel plate and laminar cooling water were computed inversely. Therefore,the temperature field in the single-face quenching process of a steel pipe was simulated using ABAQUS finite element softw are,and the relationships betw een the temperatures and quenching time at different positions of the steel pipe were obtained. In addition,the relationships betw een the cooling rates and quenching time,as w ell as betw een cooling rates and temperatures,were obtained. The simulation quickly produced accurate results,and it can be used to optimize the quenching process. In addition,the results provide a basis for rationally designing the composition of a single-face quenching steel pipe.