This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing ...This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing are first discussed. The causes of the transformer magnetic biasing are then analyzed in detail. The proposed method is based on a high-pass filter inserted in the forward path and the feedforward control. Without testing magnetic biasing of transformer, this method can eliminate magnetic biasing of transformer completely in real-time waveform feedback control systems though the zero error of the Hall effect sensors varies with time and temperature. The method has already been employed in a 90KVA AC power supply. It is shown that it offers improved performance over existing ones. In this method, no sensors are used such that the zero error of the Hall effect sensors has not any influence on the system. It is simple to design and implement. Furthermore, the method is suitable for various power applications.展开更多
A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ...A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ordinary gapless transformer could be used to develop a low cost AC voltage regulator (AVR) to provide better or comparable specifications with bulky ferro-resonant AVR types. One primary advantage of the technique is that digital control can be used to minimize harmonics. Commencing with a review of AC voltage regulator techniques for single phase power conditioning systems, an analysis and design aspects of this technique is presented with experimental results for AVRs. Guidelines on how to utilize the technique in a generalized basis is also summarized together with a summary of a technique for achieving harmonic control.展开更多
文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高...文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高频桥臂和DAB原边侧第一个桥臂进行开关复用,减小了开关器件数目。同时,相较于TP-PFC和DAB两级式AC-DC变换器,取消了直流母线电解电容并且抑制了交流电感电流尖峰。利用其拓扑特点及所提出的控制方案,实现了拓扑开关器件的全范围软开关。首先详细分析所提拓扑结构的工作特性,包括工作模态、拓扑优点、功率特性及软开关特性;其次基于对拓扑的分析,提出控制简单的控制策略;最后,对所提拓扑结构及控制方案进行实验验证。展开更多
China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so...China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.展开更多
In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict ...In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electrical market has motivated the development of methodologies to enhance the Available Transfer Capability (ATC) of the existing transmission grids. The insertion of FACTS devices in electrical systems seems to be a promising strategy to enhance ATC. In this paper, the viability and technical merits of boosting ATC using Thyristor Controlled Series Compensator (TCSC) is being analyzed. The work has been carried out on IEEE 30 bus and IEEE 118 bus systems. Bilateral and multilateral transactions are considered. Particle Swarm Optimization (PSO) algorithm and Genetic Algorithm (GA) are employed to obtain the optimal settings of TCSC.展开更多
In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of...In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system.展开更多
文摘This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing are first discussed. The causes of the transformer magnetic biasing are then analyzed in detail. The proposed method is based on a high-pass filter inserted in the forward path and the feedforward control. Without testing magnetic biasing of transformer, this method can eliminate magnetic biasing of transformer completely in real-time waveform feedback control systems though the zero error of the Hall effect sensors varies with time and temperature. The method has already been employed in a 90KVA AC power supply. It is shown that it offers improved performance over existing ones. In this method, no sensors are used such that the zero error of the Hall effect sensors has not any influence on the system. It is simple to design and implement. Furthermore, the method is suitable for various power applications.
文摘A series connected power semiconductor array, with digital control capability could be used for developing single phase AC regulators or other applications such as AC electronic loads. This technique together with an ordinary gapless transformer could be used to develop a low cost AC voltage regulator (AVR) to provide better or comparable specifications with bulky ferro-resonant AVR types. One primary advantage of the technique is that digital control can be used to minimize harmonics. Commencing with a review of AC voltage regulator techniques for single phase power conditioning systems, an analysis and design aspects of this technique is presented with experimental results for AVRs. Guidelines on how to utilize the technique in a generalized basis is also summarized together with a summary of a technique for achieving harmonic control.
文摘文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高频桥臂和DAB原边侧第一个桥臂进行开关复用,减小了开关器件数目。同时,相较于TP-PFC和DAB两级式AC-DC变换器,取消了直流母线电解电容并且抑制了交流电感电流尖峰。利用其拓扑特点及所提出的控制方案,实现了拓扑开关器件的全范围软开关。首先详细分析所提拓扑结构的工作特性,包括工作模态、拓扑优点、功率特性及软开关特性;其次基于对拓扑的分析,提出控制简单的控制策略;最后,对所提拓扑结构及控制方案进行实验验证。
文摘China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.
文摘In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electrical market has motivated the development of methodologies to enhance the Available Transfer Capability (ATC) of the existing transmission grids. The insertion of FACTS devices in electrical systems seems to be a promising strategy to enhance ATC. In this paper, the viability and technical merits of boosting ATC using Thyristor Controlled Series Compensator (TCSC) is being analyzed. The work has been carried out on IEEE 30 bus and IEEE 118 bus systems. Bilateral and multilateral transactions are considered. Particle Swarm Optimization (PSO) algorithm and Genetic Algorithm (GA) are employed to obtain the optimal settings of TCSC.
文摘In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system.