Filtering capacitor with compact configuration and a wide range of operating voltage has been attracting increasing attention for the smooth conversion of the electric signal in modern circuits.Lossless integration of...Filtering capacitor with compact configuration and a wide range of operating voltage has been attracting increasing attention for the smooth conversion of the electric signal in modern circuits.Lossless integration of capacitor units can be regarded as one of the efficient ways to achieve a wider voltage range,which has not yet been fully conquered due to the lack of rational designs of the electrode structure and integration technology.This study presents an alternatingly stacked assemble technology to conveniently fabricate compact aqueous hybrid integrated filtering capacitors on a large scale,in which a unit consists of rGO/MXene composite film as a negative electrode and PEDOT:PSS based film as a positive electrode.Benefiting from the synergistic effect of rGO and MXene components,and morphological characteristics of PEDOT:PSS,the capacitor unit exhibits outstanding AC line filtering with a large areal specific energy density of 1,015 μF V^(2)cm^(-2)(0.28 μW h cm^(-2)) at 120 Hz.After rational integration,the assembled capacitors present compact/lightweight configuration and lossless frequency response,as reflected by almost constant resistor-capacitor time constant of 0.2 ms and dissipation factor of 15% at120 Hz,identical to those of the single capacitor unit.Apart from standing alone steadily on a flower,a small volume(only 8.1 cm^(3)) of the integrated capacitor with 70 units connected in series achieves hundred-volts alternating current line filtering,which is superior to most reported filtering capacitors with sandwich configuration.This study provides insight into the fabrication and application of compact/ultralight filtering capacitors with lossless frequency response,and a wide range of operating voltage.展开更多
Recently,more and more supercapacitors(SCs)have been developed as AC line filter capacitors,which are generally named AC line filter electrochemical capacitors(FECs).Compared to traditional bulky aluminum electrolytic...Recently,more and more supercapacitors(SCs)have been developed as AC line filter capacitors,which are generally named AC line filter electrochemical capacitors(FECs).Compared to traditional bulky aluminum electrolytic capacitors(AECs),FECs have higher capacity and lower space occupancy,which makes them a strong competitor.However,different from the common SCs for energy storage,it is necessary to consider the frequency response of the SCs for AC line filtering,where the contradiction between frequency response and specific capacitance is a challenge.The researchers have proposed different solutions from the perspective of materials,morphology,and configuration for this challenge.Based on the above background,in this review,we briefly introduce the principle and parameters of AC line filter electrochemical capacitors.We systematically summarize the state-of-the-art progresses of FECs and discuss their possible application and development in the future.The development of FECs can greatly promote the planarization,integration,and miniaturization of filter capacitors,and provide a new solution for the utilization of green and unstable energy.展开更多
With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the c...With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes.展开更多
Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a h...Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a high-frequency SC is reported using Ketjen black(KB)nanoparticles doped with phosphorus(P)to achieve a high areal capacitance of up to 2.26 mF cm^(-2)along with a high-rate capability,with a phase angle of-80.2°at 120 Hz.The high performance of the phosphorus-doped KB(designated PKB)SC with a 6 M KOH aqueous electrolyte is associated with its increased surface wettability and additional capacitive sites provided by the P-doping.Density functional theory(DFT)calculations further indicate that the P-doping enhances the interactions between the electrolyte ions and the carbon surface,thus leading to an improved electrochemical performance.These results suggest that the P-doped carbonbased SC could be highly favored in replacing conventional AECs in various high-frequency electronic devices.展开更多
The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental pl...The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines.展开更多
For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplit...For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line.展开更多
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced...The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.展开更多
The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV ov...The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV overhead transmission line in China.Study on key technologies and design schemes shall be carried out to ascertain the technical principles and construction standards for project construction,which are presented in this paper based on the Southeast Shanxi-Nanyang-Jingmen test and demonstration transmission line.A comparison and analysis of technical data and economic indices between UHV line and other lines are also described.展开更多
基金supported by the NSFC(21805072,22075019,22035005)the National Key R&D Program of China(2017YFB1104300)。
文摘Filtering capacitor with compact configuration and a wide range of operating voltage has been attracting increasing attention for the smooth conversion of the electric signal in modern circuits.Lossless integration of capacitor units can be regarded as one of the efficient ways to achieve a wider voltage range,which has not yet been fully conquered due to the lack of rational designs of the electrode structure and integration technology.This study presents an alternatingly stacked assemble technology to conveniently fabricate compact aqueous hybrid integrated filtering capacitors on a large scale,in which a unit consists of rGO/MXene composite film as a negative electrode and PEDOT:PSS based film as a positive electrode.Benefiting from the synergistic effect of rGO and MXene components,and morphological characteristics of PEDOT:PSS,the capacitor unit exhibits outstanding AC line filtering with a large areal specific energy density of 1,015 μF V^(2)cm^(-2)(0.28 μW h cm^(-2)) at 120 Hz.After rational integration,the assembled capacitors present compact/lightweight configuration and lossless frequency response,as reflected by almost constant resistor-capacitor time constant of 0.2 ms and dissipation factor of 15% at120 Hz,identical to those of the single capacitor unit.Apart from standing alone steadily on a flower,a small volume(only 8.1 cm^(3)) of the integrated capacitor with 70 units connected in series achieves hundred-volts alternating current line filtering,which is superior to most reported filtering capacitors with sandwich configuration.This study provides insight into the fabrication and application of compact/ultralight filtering capacitors with lossless frequency response,and a wide range of operating voltage.
基金financially supported by the National Natural Science Foundation of China(U20A20209)Zhejiang Provincial Key Research and Development Program(2021C01030)+7 种基金Zhejiang Provincial Natural Science Foundation of China(LD19E020001)Open Project of Laboratory for Biomedical Engineering of Ministry of Education,Zhejiang UniversityNational Key R@D Program of China(2016YFB0100100)National Natural Science Foundation of China(51872283,22075279,21805273)Liaoning Revitalization Talents Program(XLYC1807153)Dalian Innovation Support Plan for High Level Talents(2019RT09)Dalian National Laboratory For Clean Energy(DNL),CAS,DNL Cooperation Fund,CAS(DNL201912 and DNL201915)DICP(DICP ZZBS201708,DICP ZZBS201802,and DICP I2020032).
文摘Recently,more and more supercapacitors(SCs)have been developed as AC line filter capacitors,which are generally named AC line filter electrochemical capacitors(FECs).Compared to traditional bulky aluminum electrolytic capacitors(AECs),FECs have higher capacity and lower space occupancy,which makes them a strong competitor.However,different from the common SCs for energy storage,it is necessary to consider the frequency response of the SCs for AC line filtering,where the contradiction between frequency response and specific capacitance is a challenge.The researchers have proposed different solutions from the perspective of materials,morphology,and configuration for this challenge.Based on the above background,in this review,we briefly introduce the principle and parameters of AC line filter electrochemical capacitors.We systematically summarize the state-of-the-art progresses of FECs and discuss their possible application and development in the future.The development of FECs can greatly promote the planarization,integration,and miniaturization of filter capacitors,and provide a new solution for the utilization of green and unstable energy.
文摘With rapid growth of power demand, transmission capacity is also in urgent need of upgrading. In some cases, converting existing AC transmission lines to DC lines can Improve the transmission capacity and reduce the construction investment. In this paper, the upstream finite element method was expanded to calculate the total electric field of same tower multi-circuit DC lines converted from double-circuit AC lines, and the validity of the algorithm was confirmed by experiments. Taking a DC line converted from a typical same tower 500 kV double-circuit AC transmission line as an example, the surface electric field and the ground total electric field in different pole conductor arrangement schemes were calculated and analyzed, and the critical height of pole conductors for DC lines in residential and non-residential area were determined. Then, the corridor width of DC and AC lines at critical height in residential and non-residential areas before and after AC-DC line transformation were compared. The results indicate that for DC lines converted from common 500 kV double-circuit AC lines, the ground total electric field can meet the requirements of corresponding standard with appropriate pole conductor arrangement schemes.
基金supported by grants from the National Research Foundation of Korea(NRF-2020R1A2C2008798)Korea University。
文摘Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a high-frequency SC is reported using Ketjen black(KB)nanoparticles doped with phosphorus(P)to achieve a high areal capacitance of up to 2.26 mF cm^(-2)along with a high-rate capability,with a phase angle of-80.2°at 120 Hz.The high performance of the phosphorus-doped KB(designated PKB)SC with a 6 M KOH aqueous electrolyte is associated with its increased surface wettability and additional capacitive sites provided by the P-doping.Density functional theory(DFT)calculations further indicate that the P-doping enhances the interactions between the electrolyte ions and the carbon surface,thus leading to an improved electrochemical performance.These results suggest that the P-doped carbonbased SC could be highly favored in replacing conventional AECs in various high-frequency electronic devices.
基金supported by National Natural Science Foundation of China(Nos.51277061 and 51420105011)
文摘The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines.
基金Project supported by Funds for Innovative Research Groups of China (51021005), National Basic Research Program of China (973 Program) (2009CB724504), National Natural Science Foundation of China(50707036).
基金supported by Science and Technology Project of SGCC(SG1021)
文摘For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line.
文摘The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.
文摘The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV overhead transmission line in China.Study on key technologies and design schemes shall be carried out to ascertain the technical principles and construction standards for project construction,which are presented in this paper based on the Southeast Shanxi-Nanyang-Jingmen test and demonstration transmission line.A comparison and analysis of technical data and economic indices between UHV line and other lines are also described.