VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a bac...VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity.展开更多
With the development of more electric aircraft(MEA),higher demands for electrical energy are put forward in generation systems.Compared to constant frequency AC(CFAC)generation systems,the constant speed drive(CSD)is ...With the development of more electric aircraft(MEA),higher demands for electrical energy are put forward in generation systems.Compared to constant frequency AC(CFAC)generation systems,the constant speed drive(CSD)is eliminated and integrated starter/generator(SG)can be realized in variable frequency AC(VFAC)generation systems.In this paper,an overview of VFAC generators for safety-critical aircraft applications is presented,with a particular focus on the key features and requirements of candidate generators and the starting control strategies.Wound rotor synchronous machines(WRSMs)are typical generators used in VFAC generation systems so far.Meanwhile,hybrid excitation synchronous machines(HESMs)and cage-type induction machines are promising candidates for VFAC generation systems.The generation operation of WRSM is relatively mature,however,the SG technology of WRSM is still full of challenges.As one of the most important issues,the starting excitation methods of WRSM are summarized.An HESM-based VFAC SG system is proposed and developed in this paper.The experimental results show that the starting mode,transition mode and generating mode of the VFAC SG system are realized.The continuous progress of VFAC generation system makes great contributions to the realization of MEA.展开更多
文摘VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity.
基金Supported by the National Natural Science Foundation for Outstanding Young Scholar of China under Award 51622704Jiangsu Provincial Science Funds for Distinguished Young Scientists under Award BK20150033.
文摘With the development of more electric aircraft(MEA),higher demands for electrical energy are put forward in generation systems.Compared to constant frequency AC(CFAC)generation systems,the constant speed drive(CSD)is eliminated and integrated starter/generator(SG)can be realized in variable frequency AC(VFAC)generation systems.In this paper,an overview of VFAC generators for safety-critical aircraft applications is presented,with a particular focus on the key features and requirements of candidate generators and the starting control strategies.Wound rotor synchronous machines(WRSMs)are typical generators used in VFAC generation systems so far.Meanwhile,hybrid excitation synchronous machines(HESMs)and cage-type induction machines are promising candidates for VFAC generation systems.The generation operation of WRSM is relatively mature,however,the SG technology of WRSM is still full of challenges.As one of the most important issues,the starting excitation methods of WRSM are summarized.An HESM-based VFAC SG system is proposed and developed in this paper.The experimental results show that the starting mode,transition mode and generating mode of the VFAC SG system are realized.The continuous progress of VFAC generation system makes great contributions to the realization of MEA.