In view of the variable parameters that affect the transient stability of electromagnetic torque and mechanical torque balance in AC-DC system,and the uncertainty of wind power in large-scale interconnection of wind f...In view of the variable parameters that affect the transient stability of electromagnetic torque and mechanical torque balance in AC-DC system,and the uncertainty of wind power in large-scale interconnection of wind farm.This paper proposes a linear parameter varying(LPV)robust feedback control method for transient stability of interconnected systems.The proposed LPV robust feedback control method uses the DC channel power control and the mechanical power in the interconnected system as the control target to improve the transient stability of the interconnected system with wind farm channel.Firstly,aiming at the strong nonlinear characteristics of the interconnected system,the power balance and the wind power output uncertainty in the transient process,the transient process is designed as a linear model of variable parameters.Then,the H∞robust output feedback controller is designed according to the LPV model.The transient stability control strategy topology and transfer function of the interconnected system are proposed.Finally,the proposed scheme is verified by an interconnected system formed by four equal-value grids through AC and DC lines in a digital simulation platform.The results show that the LPV robust feedback control model proposed in this paper has better response characteristics and transient stability control effects for interconnected systems with wind power weak sendingend system.展开更多
In view of the reactive power coordination difficulties caused by reactive power strong coupling,the provincial power grids in the interconnected system are formed by the multi-AC/DC transmission.Wind power channels a...In view of the reactive power coordination difficulties caused by reactive power strong coupling,the provincial power grids in the interconnected system are formed by the multi-AC/DC transmission.Wind power channels are under the conditions of large-scale long-distance transmission of wind power and other forms of renewable power generation.The AC-DC hybrid power flow equation of the interconnected system,including the AC-DC tie lines,is presented in this paper,along with the robust dynamic evolutionary optimization of the reactive power system in interconnected systems under fluctuating and uncertain wind power conditions.Therefore,the rapid collaborative optimization of reactive power flow and the exchange of reactive power between tie lines between provincial power grids are realized.The analysis was made by taking four interconnected large-scale provincial power grids of Eastern Mongolia,Jilin,Liaoning and Shandong as an example.The simulation results demonstrate the effectiveness and superiority of the proposed reactive power dynamic multi-objective optimization method for interconnected power grids.展开更多
基金This study was supported in part by the National Key R&D Program of China(2017YFB0902100).
文摘In view of the variable parameters that affect the transient stability of electromagnetic torque and mechanical torque balance in AC-DC system,and the uncertainty of wind power in large-scale interconnection of wind farm.This paper proposes a linear parameter varying(LPV)robust feedback control method for transient stability of interconnected systems.The proposed LPV robust feedback control method uses the DC channel power control and the mechanical power in the interconnected system as the control target to improve the transient stability of the interconnected system with wind farm channel.Firstly,aiming at the strong nonlinear characteristics of the interconnected system,the power balance and the wind power output uncertainty in the transient process,the transient process is designed as a linear model of variable parameters.Then,the H∞robust output feedback controller is designed according to the LPV model.The transient stability control strategy topology and transfer function of the interconnected system are proposed.Finally,the proposed scheme is verified by an interconnected system formed by four equal-value grids through AC and DC lines in a digital simulation platform.The results show that the LPV robust feedback control model proposed in this paper has better response characteristics and transient stability control effects for interconnected systems with wind power weak sendingend system.
基金This work was supported by the National Key Research and Development Program of China under Grant No.2017YFB0902100.
文摘In view of the reactive power coordination difficulties caused by reactive power strong coupling,the provincial power grids in the interconnected system are formed by the multi-AC/DC transmission.Wind power channels are under the conditions of large-scale long-distance transmission of wind power and other forms of renewable power generation.The AC-DC hybrid power flow equation of the interconnected system,including the AC-DC tie lines,is presented in this paper,along with the robust dynamic evolutionary optimization of the reactive power system in interconnected systems under fluctuating and uncertain wind power conditions.Therefore,the rapid collaborative optimization of reactive power flow and the exchange of reactive power between tie lines between provincial power grids are realized.The analysis was made by taking four interconnected large-scale provincial power grids of Eastern Mongolia,Jilin,Liaoning and Shandong as an example.The simulation results demonstrate the effectiveness and superiority of the proposed reactive power dynamic multi-objective optimization method for interconnected power grids.