There are issues with flexible DC transmission system such as a lack of control freedom over power flow.In order to tackle these issues,a DC power flow controller(DCPFC)is incorporated into a multi-terminal,flexible D...There are issues with flexible DC transmission system such as a lack of control freedom over power flow.In order to tackle these issues,a DC power flow controller(DCPFC)is incorporated into a multi-terminal,flexible DC power grid.In recent years,a multi-port DC power flow controller based on a modular multi-level converter has become a focal point of research due to its simple structure and robust scalability.This work proposes a model predictive control(MPC)strategy for multi-port interline DC power flow controllers in order to improve their steady-state dynamic performance.Initially,the mathematical model of a multi-terminal DC power grid with a multi-port interline DC power flow controller is developed,and the relationship between each regulated variable and control variable is determined;The power flow controller is then discretized,and the cost function and weight factor are built with numerous control objectives.Sub module sorting method and nearest level approximation modulation regulate the power flow controller;Lastly,theMATLAB/Simulink simulation platformis used to verify the correctness of the establishedmathematicalmodel and the control performance of the suggestedMPC strategy.Finally,it is demonstrated that the control strategy possesses the benefits of robust dynamic performance,multiobjective control,and a simple structure.展开更多
文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高...文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高频桥臂和DAB原边侧第一个桥臂进行开关复用,减小了开关器件数目。同时,相较于TP-PFC和DAB两级式AC-DC变换器,取消了直流母线电解电容并且抑制了交流电感电流尖峰。利用其拓扑特点及所提出的控制方案,实现了拓扑开关器件的全范围软开关。首先详细分析所提拓扑结构的工作特性,包括工作模态、拓扑优点、功率特性及软开关特性;其次基于对拓扑的分析,提出控制简单的控制策略;最后,对所提拓扑结构及控制方案进行实验验证。展开更多
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D...The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.展开更多
This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of i...This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.展开更多
A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t...A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.展开更多
China is an important country in iron and steel industry.Power electronics converters are widely used.For the cold rolling mills of high speed,AC-DC-AC converters should be used.In the paper,the design and the control...China is an important country in iron and steel industry.Power electronics converters are widely used.For the cold rolling mills of high speed,AC-DC-AC converters should be used.In the paper,the design and the control system of the large power three-level AC - DC - AC converter with IGCTs is investigated,and a back-to-back large power three-level AC - DC - AC converter with IGCTs has been got. With a series experiments,the performance of the converter is examined.The experiment result indicates the converter reaches the design requirement and it shows excellent performance.The converter system has been put into use safely.It is estimated that the AC - DC - AC converter system will be used in the drive systems for rolling mills in the near future.展开更多
In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the us...In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the use of controllable FACTS devices. Two types of FACTS devices, thyristor controlled series compensators (TCSC) and Static VAR Compensator (SVC) are considered in this method. The basic bacterial foraging algorithm (BFA) is an evolutionary optimization technique inspired by the foraging behavior of the E. coli bacteria. The strategy of the OPF problem is decomposed in two sub-problems, the first sub-problem related to active power planning to minimize the fuel cost function, and the second sub-problem designed to make corrections to the voltage deviation and reactive power violation based in an efficient reactive power planning of multi Static VAR Compensator (SVC). The specified power flow control constraints due to the use of FACTS devices are included in the OPF problem. The proposed method decomposes the solution of such modified OPF problem into two sub problems’ iteration. The first sub problem is a power flow control problem and the second sub problem is a modified Bacterial foraging algorithm (MBFA) OPF problem. The two sub problems are solved iteratively until convergence. Case studies are presented to show the effectiveness of the proposed method.展开更多
基金funded by National Natural Science Foundation of China (52177074).
文摘There are issues with flexible DC transmission system such as a lack of control freedom over power flow.In order to tackle these issues,a DC power flow controller(DCPFC)is incorporated into a multi-terminal,flexible DC power grid.In recent years,a multi-port DC power flow controller based on a modular multi-level converter has become a focal point of research due to its simple structure and robust scalability.This work proposes a model predictive control(MPC)strategy for multi-port interline DC power flow controllers in order to improve their steady-state dynamic performance.Initially,the mathematical model of a multi-terminal DC power grid with a multi-port interline DC power flow controller is developed,and the relationship between each regulated variable and control variable is determined;The power flow controller is then discretized,and the cost function and weight factor are built with numerous control objectives.Sub module sorting method and nearest level approximation modulation regulate the power flow controller;Lastly,theMATLAB/Simulink simulation platformis used to verify the correctness of the establishedmathematicalmodel and the control performance of the suggestedMPC strategy.Finally,it is demonstrated that the control strategy possesses the benefits of robust dynamic performance,multiobjective control,and a simple structure.
文摘文中提出一种新型单级式隔离AC-DC变换器及控制方案。所提结构在不改变图腾柱无桥功率因数校正(totem pole bridge-free power factor correction,TP-PFC)和双向全桥(dual active bridge,DAB)两级式AC-DC变换器特性的前提下,将TP-PFC高频桥臂和DAB原边侧第一个桥臂进行开关复用,减小了开关器件数目。同时,相较于TP-PFC和DAB两级式AC-DC变换器,取消了直流母线电解电容并且抑制了交流电感电流尖峰。利用其拓扑特点及所提出的控制方案,实现了拓扑开关器件的全范围软开关。首先详细分析所提拓扑结构的工作特性,包括工作模态、拓扑优点、功率特性及软开关特性;其次基于对拓扑的分析,提出控制简单的控制策略;最后,对所提拓扑结构及控制方案进行实验验证。
基金supported by National Key Research and Development Program of China (2016YFB0900500,2017YFB0903100)the State Grid Science and Technology Project (SGRI-DL-F1-51-011)
文摘The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.
基金supported by Creative Challenge Research Program (2021R1I1A1A01052521)the BK-21 FOUR program through the National Research Foundation of Korea (NRF)under the Ministry of Education.
文摘This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.
文摘A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.
文摘China is an important country in iron and steel industry.Power electronics converters are widely used.For the cold rolling mills of high speed,AC-DC-AC converters should be used.In the paper,the design and the control system of the large power three-level AC - DC - AC converter with IGCTs is investigated,and a back-to-back large power three-level AC - DC - AC converter with IGCTs has been got. With a series experiments,the performance of the converter is examined.The experiment result indicates the converter reaches the design requirement and it shows excellent performance.The converter system has been put into use safely.It is estimated that the AC - DC - AC converter system will be used in the drive systems for rolling mills in the near future.
文摘In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the use of controllable FACTS devices. Two types of FACTS devices, thyristor controlled series compensators (TCSC) and Static VAR Compensator (SVC) are considered in this method. The basic bacterial foraging algorithm (BFA) is an evolutionary optimization technique inspired by the foraging behavior of the E. coli bacteria. The strategy of the OPF problem is decomposed in two sub-problems, the first sub-problem related to active power planning to minimize the fuel cost function, and the second sub-problem designed to make corrections to the voltage deviation and reactive power violation based in an efficient reactive power planning of multi Static VAR Compensator (SVC). The specified power flow control constraints due to the use of FACTS devices are included in the OPF problem. The proposed method decomposes the solution of such modified OPF problem into two sub problems’ iteration. The first sub problem is a power flow control problem and the second sub problem is a modified Bacterial foraging algorithm (MBFA) OPF problem. The two sub problems are solved iteratively until convergence. Case studies are presented to show the effectiveness of the proposed method.