Blind tip reconstruction(BTR) method is one of the favorable methods to estimate the atomic force microscopy(AFM) probe shape. The exact shape of the characterizer is not required for BTR, while the geometry of the sa...Blind tip reconstruction(BTR) method is one of the favorable methods to estimate the atomic force microscopy(AFM) probe shape. The exact shape of the characterizer is not required for BTR, while the geometry of the sample may affect the reconstruction significantly. A cone-shaped array sample was chosen as a characterizer to be evaluated. The target AFM probe to be reconstructed was a diamond triangular pyramid probe with two feature angles, namely front angle(FA) and back angle(BA). Four conical structures with different semi-angles were dilated by the pyramid probe. Simulation of scanning process demonstrates that it is easy to judge from the images of the isolated rotary structure, cone-shaped, the suitability of the sample to be a tip characterizer for a pyramid probe. The cone-shaped array sample was repeatedly scanned 50 times by the diamond probe using an AFM. The series of scanning images shrank gradually and more information of the probe was exhibited in the images, indicating that the characterizer has been more suitable for BTR. The feature angle FA of the characterizer increasingly reduces during the scanning process. A self-adaptive grinding between the probe and the characterizer contributes to BTR of the diamond pyramid probe.展开更多
An improved arc discharge method is developed to fabricate carbon nanotube probe of atomic force microscopy (AFM) here. First, silicon probe and carbon nanotube are manipulated under an optical microscope by two hig...An improved arc discharge method is developed to fabricate carbon nanotube probe of atomic force microscopy (AFM) here. First, silicon probe and carbon nanotube are manipulated under an optical microscope by two high precision microtranslators. When silicon probe and carbon nanotube are very close, several tens voltage is applied between them. And carbon nanotube is divided and attached to the end of silicon probe, which mainly due to the arc welding function. Comparing with the arc discharge method before, the new method here needs no coat silicon probe with metal film in advance, which can greatly reduce the fabrication's difficulty. The fabricated carbon nanotube probe shows good property of higher aspect ratio and can more accurately reflect the true topography of silicon grating than silicon probe. Under the same image drive force, carbon nanotube probe had less indentation depth on soft triblock copolymer sample than silicon probe. This showed that carbon nanotube probe has lower spring constant and less damage to the scan sample than silicon probe.展开更多
为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路...为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路步骤。该系统的光路一致性组件采用光束偏转法对探针位置与偏转进行放大与监测,并使用高精度位移与角度调节平台进行探针相对于探针夹的方位调整。通过实物搭建对探针一致性效果进行了验证,并对紫外光(Ultraviolet,UV)胶水固化过程导致探针位置偏移影响;探针不同偏移量时产生的探测器噪音对AFM系统成像质量影响进行了系统分析。实验结果表明:经由该系统装配的探针平均位置精度接近1.1μm;并且在AFM系统中更换一致性探针仅需8 s。该系统实现了高精度且质量稳定的探针一致性装配,极大地简化了AFM系统重新校准光路的操作步骤,其与自动换针装置配合可有效提升工业计量型AFM的操作与测量性能。展开更多
In this paper, a two-dimensional nanometer scale tip-plate discharge model has been employed to study nanoscale electrical discharge in atmospheric conditions. The field strength dis- tributions in a nanometer scale t...In this paper, a two-dimensional nanometer scale tip-plate discharge model has been employed to study nanoscale electrical discharge in atmospheric conditions. The field strength dis- tributions in a nanometer scale tip-to-plate electrode arrangement were calculated using the finite element analysis (FEA) method, and the influences of applied voltage amplitude and frequency as well as gas gap distance on the variation of effective discharge range (EDR) on the plate were also investigated and discussed. The simulation results show that the probe with a wide tip will cause a larger effective discharge range on the plate; the field strength in the gap is notably higher than that induced by the sharp tip probe; the effective discharge range will increase linearly with the rise of excitation voltage, and decrease nonlinearly with the rise of gap length. In addition, probe dimension, especially the width/height ratio, affects the effective discharge range in different manners. With the width/height ratio rising from 1 : 1 to 1 : 10, the effective discharge range will maintain stable when the excitation voltage is around 50 V. This will increase when the excitation voltage gets higher and decrease as the excitation voltage gets lower. Fhrthermore, when the gap length is 5 nm and the excitation voltage is below 20 V, the diameter of EDR in our simulation is about 150 nm, which is consistent with the experiment results reported by other research groups. Our work provides a preliminary understanding of nanometer scale discharges and establishes a predictive structure-behavior relationship.展开更多
An improved arc discharge method is developed to fabricate the carbon nanotube probe. In this method, the silicon probe and the carbon nanotube were manipulated under an optical microscope. When the silicon probe and ...An improved arc discharge method is developed to fabricate the carbon nanotube probe. In this method, the silicon probe and the carbon nanotube were manipulated under an optical microscope. When the silicon probe and the carbon nanotube were very close, 30-60 V dc or ac was applied between them, and the carbon nanotube was divided and attached to the end of the silicon probe. Comparing with the arc discharge method, the new method need not coat the silicon probe with metal in advance, which can greatly reduce the fabrication difficulty and cost. The fabricated carbon nanotube probe exhibits the good property of high aspect ratio and can reflect the true topography more accurately than the silicon probe.展开更多
Several fundamental problems in hydrophobic force measurements using atomic force microscope (AFM) are dis-cussed in this paper. A novel method for colloid probe preparation based on chemical etching technology is pro...Several fundamental problems in hydrophobic force measurements using atomic force microscope (AFM) are dis-cussed in this paper. A novel method for colloid probe preparation based on chemical etching technology is proposed, which is specially fit for the unique demands of hydrophobic force measurements by AFM. The features of three different approaches for determining spring constants of rectangular cantilevers, including geometric dimension, Cleveland and Sader methods are com-pared. The influences of the sizes of the colloids on the measurements of the hydrophobic force curves are investigated. Our experimental results showed that by selecting colloid probe with proper spring constant and tip size, the hydrophobic force and the complete hydrophobic interaction force curve can be measured by using AFM.展开更多
The membrane method based on adaptive wettability shows great advantages in oil-water separation.At present,researches focus on the excellent application performance of the membrane material,while the quantitative ana...The membrane method based on adaptive wettability shows great advantages in oil-water separation.At present,researches focus on the excellent application performance of the membrane material,while the quantitative analysis of interactions in oil-water separation is rarely recognized.Herein,we constructed an adaptable wettability membrane with multiple polymer networks by polydopamine(PDA)and mussel-inspired amphiphilic polymer.Based on the Owens three-probe liquid method,the surface energy of the modified membrane was verified to meet the adaptive wettability conditions,with surface energies(γ-8)of 147.6 mJ m^(−2)(superhydrophilic/underwater superoleophobic)and 49.87 mJ m^(−2)(superhydrophobic/superoleophobic),respectively.The adhesion or repulsion of the membrane to the oil phase under different conditions during the separation process was quantified by the chemical probe AFM technique.In addition,the oil-water selective separation mechanism was further analyzed in a simplified membrane microchannel model.The results show that the different wetting produces capillary additional pressure in opposite directions,resulting in different energies to be overcome when the oil or water passes through the microchannels,thus achieving selective separation.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.51305298,No.51675379)Tianjin Research Program of Application Foundation and Advanced Technology(Grant No.13JCQNJC04700)
文摘Blind tip reconstruction(BTR) method is one of the favorable methods to estimate the atomic force microscopy(AFM) probe shape. The exact shape of the characterizer is not required for BTR, while the geometry of the sample may affect the reconstruction significantly. A cone-shaped array sample was chosen as a characterizer to be evaluated. The target AFM probe to be reconstructed was a diamond triangular pyramid probe with two feature angles, namely front angle(FA) and back angle(BA). Four conical structures with different semi-angles were dilated by the pyramid probe. Simulation of scanning process demonstrates that it is easy to judge from the images of the isolated rotary structure, cone-shaped, the suitability of the sample to be a tip characterizer for a pyramid probe. The cone-shaped array sample was repeatedly scanned 50 times by the diamond probe using an AFM. The series of scanning images shrank gradually and more information of the probe was exhibited in the images, indicating that the characterizer has been more suitable for BTR. The feature angle FA of the characterizer increasingly reduces during the scanning process. A self-adaptive grinding between the probe and the characterizer contributes to BTR of the diamond pyramid probe.
基金This project is supported by National Natural Science Foundation of China (No.50205006).
文摘An improved arc discharge method is developed to fabricate carbon nanotube probe of atomic force microscopy (AFM) here. First, silicon probe and carbon nanotube are manipulated under an optical microscope by two high precision microtranslators. When silicon probe and carbon nanotube are very close, several tens voltage is applied between them. And carbon nanotube is divided and attached to the end of silicon probe, which mainly due to the arc welding function. Comparing with the arc discharge method before, the new method here needs no coat silicon probe with metal film in advance, which can greatly reduce the fabrication's difficulty. The fabricated carbon nanotube probe shows good property of higher aspect ratio and can more accurately reflect the true topography of silicon grating than silicon probe. Under the same image drive force, carbon nanotube probe had less indentation depth on soft triblock copolymer sample than silicon probe. This showed that carbon nanotube probe has lower spring constant and less damage to the scan sample than silicon probe.
文摘为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路步骤。该系统的光路一致性组件采用光束偏转法对探针位置与偏转进行放大与监测,并使用高精度位移与角度调节平台进行探针相对于探针夹的方位调整。通过实物搭建对探针一致性效果进行了验证,并对紫外光(Ultraviolet,UV)胶水固化过程导致探针位置偏移影响;探针不同偏移量时产生的探测器噪音对AFM系统成像质量影响进行了系统分析。实验结果表明:经由该系统装配的探针平均位置精度接近1.1μm;并且在AFM系统中更换一致性探针仅需8 s。该系统实现了高精度且质量稳定的探针一致性装配,极大地简化了AFM系统重新校准光路的操作步骤,其与自动换针装置配合可有效提升工业计量型AFM的操作与测量性能。
基金supported in part by External Cooperation Program of Chinese Academy of Sciences(No.GJHZ1218)National Natural Science Foundation of China(No.61004133)SSSTC JRP awards 2011(IZLCZ2 138953)
文摘In this paper, a two-dimensional nanometer scale tip-plate discharge model has been employed to study nanoscale electrical discharge in atmospheric conditions. The field strength dis- tributions in a nanometer scale tip-to-plate electrode arrangement were calculated using the finite element analysis (FEA) method, and the influences of applied voltage amplitude and frequency as well as gas gap distance on the variation of effective discharge range (EDR) on the plate were also investigated and discussed. The simulation results show that the probe with a wide tip will cause a larger effective discharge range on the plate; the field strength in the gap is notably higher than that induced by the sharp tip probe; the effective discharge range will increase linearly with the rise of excitation voltage, and decrease nonlinearly with the rise of gap length. In addition, probe dimension, especially the width/height ratio, affects the effective discharge range in different manners. With the width/height ratio rising from 1 : 1 to 1 : 10, the effective discharge range will maintain stable when the excitation voltage is around 50 V. This will increase when the excitation voltage gets higher and decrease as the excitation voltage gets lower. Fhrthermore, when the gap length is 5 nm and the excitation voltage is below 20 V, the diameter of EDR in our simulation is about 150 nm, which is consistent with the experiment results reported by other research groups. Our work provides a preliminary understanding of nanometer scale discharges and establishes a predictive structure-behavior relationship.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50205006)
文摘An improved arc discharge method is developed to fabricate the carbon nanotube probe. In this method, the silicon probe and the carbon nanotube were manipulated under an optical microscope. When the silicon probe and the carbon nanotube were very close, 30-60 V dc or ac was applied between them, and the carbon nanotube was divided and attached to the end of the silicon probe. Comparing with the arc discharge method, the new method need not coat the silicon probe with metal in advance, which can greatly reduce the fabrication difficulty and cost. The fabricated carbon nanotube probe exhibits the good property of high aspect ratio and can reflect the true topography more accurately than the silicon probe.
基金Project (No. 20276057) supported by the National Natural ScienceFoundation of China
文摘Several fundamental problems in hydrophobic force measurements using atomic force microscope (AFM) are dis-cussed in this paper. A novel method for colloid probe preparation based on chemical etching technology is proposed, which is specially fit for the unique demands of hydrophobic force measurements by AFM. The features of three different approaches for determining spring constants of rectangular cantilevers, including geometric dimension, Cleveland and Sader methods are com-pared. The influences of the sizes of the colloids on the measurements of the hydrophobic force curves are investigated. Our experimental results showed that by selecting colloid probe with proper spring constant and tip size, the hydrophobic force and the complete hydrophobic interaction force curve can be measured by using AFM.
基金We gratefully acknowledge the financial support from National Key Research and Development Project,China(2019YFA0708700)the National Natural Science Foundation of China(52222403,52074333)the Innovation Fund Project for graduate students of China University of Petroleum(East China)(22CX04049A).
文摘The membrane method based on adaptive wettability shows great advantages in oil-water separation.At present,researches focus on the excellent application performance of the membrane material,while the quantitative analysis of interactions in oil-water separation is rarely recognized.Herein,we constructed an adaptable wettability membrane with multiple polymer networks by polydopamine(PDA)and mussel-inspired amphiphilic polymer.Based on the Owens three-probe liquid method,the surface energy of the modified membrane was verified to meet the adaptive wettability conditions,with surface energies(γ-8)of 147.6 mJ m^(−2)(superhydrophilic/underwater superoleophobic)and 49.87 mJ m^(−2)(superhydrophobic/superoleophobic),respectively.The adhesion or repulsion of the membrane to the oil phase under different conditions during the separation process was quantified by the chemical probe AFM technique.In addition,the oil-water selective separation mechanism was further analyzed in a simplified membrane microchannel model.The results show that the different wetting produces capillary additional pressure in opposite directions,resulting in different energies to be overcome when the oil or water passes through the microchannels,thus achieving selective separation.