期刊文献+
共找到8,176篇文章
< 1 2 250 >
每页显示 20 50 100
An inversely designed integrated spectrometer with reconfigurable performance and ultra-low power consumption
1
作者 Ang Li Yifan Wu +3 位作者 Chang Wang Feixia Bao Zongyin Yang Shilong Pan 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第8期43-54,共12页
Despite the pressing demand for integrated spectrometers,a solution that deliver high-performance while being practically operated is still missing.Furthermore,current integrated spectrometers lack reconfigurability i... Despite the pressing demand for integrated spectrometers,a solution that deliver high-performance while being practically operated is still missing.Furthermore,current integrated spectrometers lack reconfigurability in their performance,which is highly desirable for dynamic working scenarios.This study presents a viable solution by demonstrating a userfriendly,reconfigurable spectrometer on silicon.At the core of this innovative spectrometer is a programmable photonic circuit capable of exhibiting diverse spectral responses,which can be significantly adjusted using on-chip phase shifters.The distinguishing feature of our spectrometer lies in its inverse design approach,facilitating effortless control and efficient manipulation of the programmable circuit.By eliminating the need for intricate configuration,our design reduces power consumption and mitigates control complexity.Additionally,our reconfigurable spectrometer offers two distinct operating conditions.In the Ultra-High-Performance mode,it is activated by multiple phase-shifters and achieves exceptional spectral resolution in the picometer scale while maintaining broad bandwidth.On the other hand,the Ease-of-Use mode further simplifies the control logic and reduces power consumption by actuating a single-phase shifter.Although this mode provides a slightly degraded spectral resolution of approximately 0.3 nm,it prioritizes ease of use and is wellsuited for applications where ultra-fine spectral reconstruction is not a primary requirement. 展开更多
关键词 silicon photonics integrated spectrometers computational spectrometers
下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
2
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics X-ray diagnostics Scintillator PIN diode
下载PDF
Design and implementation of the monochromator shielding for the cold neutron spectrometers XINGZHI and BOYA
3
作者 汪晋辰 刘娟娟 +6 位作者 徐大业 Florian Grünauer 郝丽杰 刘蕴韬 张红霞 程鹏 鲍威 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期96-102,共7页
An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulatio... An innovative monochromator shielding is designed and implemented for the cold neutron spectrometers XINGZHI and BOYA operated by Renmin University of China at China Advanced Research Reactor.Via Monte Carlo simulations and careful mechanical designs,a shielding configuration has been successfully developed to satisfy safety requirements of below 3μSv/h dose rate at its exterior,meanwhile fulfilling space,floor load and nonmagnetic requirements.Composite materials are utilized to form the sandwich-type shielding walls:the inner layer of boron carbide rubber,the middle layer of steel-encased lead and the outer layer of borated polyethylene.Special-shaped liftable shielding blocks are incorporated to facilitate a continuous adjustment of the neutron energy while preventing radiation leakage.Our work has demonstrated that by utilizing composite shielding materials,along with the sandwich structure and liftable shielding blocks,a compact and lightweight shielding solution can be achieved.This enables the realization of advanced neutron scattering instruments that provide expanded space of measurement,larger energy and momentum coverage,and higher flux on the sample.This shielding represents the first of its kind in neutron scattering instruments in China.Following its successful operation,it has been subsequently employed by other neutron instruments across the country. 展开更多
关键词 neutron scattering cold neutron spectrometer monochromator shielding sandwich shielding structure
下载PDF
A seven-crystal spectrometer for high-energy resolution X-ray spectroscopy at Shanghai Synchrotron Radiation Facility
4
作者 Bing-Bao Mei Liang-Xin Wang +6 位作者 Song-Qi Gu Xiao-Zhi Su Shuo Zhang Yao Wei Jing-Yuan Ma Zheng Jiang Fei Song 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期82-91,共10页
A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facili... A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research. 展开更多
关键词 X-ray emission spectroscopy High-energy-resolution X-ray spectrometer Johann geometry Energy materials SSRF
下载PDF
Mid-infrared Optical Frequency Comb-based Fourier Transform Spectrometer for Broadband Molecular Spectroscopy
5
作者 Feihu Cheng Weixiong Zhao +5 位作者 Bo Fang Nana Yang Shuangshuang Li Weijun Zhang Lunhua Deng Weidong Chen 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2024年第4期471-480,I0093,共11页
Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre... Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)]. 展开更多
关键词 Mid-infrared optical frequency comb Multi-pass cell Fourier transform infrared spectrometer
下载PDF
Artificial neural network-based method for discriminating Compton scattering events in high-purity germaniumγ-ray spectrometer
6
作者 Chun-Di Fan Guo-Qiang Zeng +5 位作者 Hao-Wen Deng Lei Yan Jian Yang Chuan-Hao Hu Song Qing Yang Hou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期64-84,共21页
To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resul... To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively. 展开更多
关键词 High-purity germaniumγ-ray spectrometer Pulse-shape discrimination Compton scattering Artificial neural network Minimum detectable activity
下载PDF
An empirical method for joint inversion of wave and wind parameters based on SAR and wave spectrometer data
7
作者 Yong Wan Xiaona Zhang +2 位作者 Shuyan Lang Ennan Ma Yongshou Dai 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第5期133-144,共12页
Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea... Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea surface phenomena.SAR systems,for instance,are hindered by an azimuth cut-off phenomenon in sea surface wind field observation.Wave spectrometers,while unaffected by the azimuth cutoff phenomenon,struggle with low azimuth resolution,impacting the capture of detailed wave and wind field data.This study utilizes SAR and surface wave investigation and monitoring(SWIM)data to initially extract key feature parameters,which are then prioritized using the extreme gradient boosting(XGBoost)algorithm.The research further addresses feature collinearity through a combined analysis of feature importance and correlation,leading to the development of an inversion model for wave and wind parameters based on XGBoost.A comparative analysis of this model with ERA5 reanalysis and buoy data for of significant wave height,mean wave period,wind direction,and wind speed reveals root mean square errors of 0.212 m,0.525 s,27.446°,and 1.092 m/s,compared to 0.314 m,0.888 s,27.698°,and 1.315 m/s from buoy data,respectively.These results demonstrate the model’s effective retrieval of wave and wind parameters.Finally,the model,incorporating altimeter and scatterometer data,is evaluated against SAR/SWIM single and dual payload inversion methods across different wind speeds.This comparison highlights the model’s superior inversion accuracy over other methods. 展开更多
关键词 synthetic aperture radar(SAR) wave spectrometer extreme gradient boosting(XGBoost) joint inversion method wave and wind parameters
下载PDF
利用ATR-FTIR研究脂质纳米粒的鼻黏液渗透性
8
作者 王健敏 李雪梅 +3 位作者 马士超 李志勇 唐华东 马凤森 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2024年第4期1052-1060,共9页
鼻黏液是影响疫苗和药物经鼻吸收的首要屏障。由于干扰因素复杂多变,在体评价黏液渗透性较难实施,多采用体外评价。现有的药物鼻黏液渗透性检测方法如细胞模型法、多粒子示踪技术等,存在细胞培养周期长、操作繁琐、成本高、可获得信息... 鼻黏液是影响疫苗和药物经鼻吸收的首要屏障。由于干扰因素复杂多变,在体评价黏液渗透性较难实施,多采用体外评价。现有的药物鼻黏液渗透性检测方法如细胞模型法、多粒子示踪技术等,存在细胞培养周期长、操作繁琐、成本高、可获得信息少且需要进行荧光标记等不足,对鼻黏膜制剂的体外评价具有很大的局限性,因此迫切需要建立一种快速、简便、灵敏的鼻黏膜制剂黏液渗透性评价方法。基于衰减全反射-傅里叶红外光谱(ATR-FTIR)对药物结构以及粘蛋白二级结构变化的敏感性,利用其对不同性质(粒径与电荷)脂质体的鼻黏液渗透性进行研究,通过FTIR图谱分析不同脂质纳米粒与黏液中粘蛋白的相互作用,建立了鼻黏膜制剂黏液渗透性的体外评价方法。方法学研究表明,对于聚乙二醇10000(PEG10000)、壳聚糖、海藻酸钠脂质体,该方法线性关系分别为Y=2.3866X+2.154、Y=1.8703X+0.2789、Y=1.13014X+0.0609,线性相关系数分别为0.9958、0.9945、0.9909,精密度RSD值分别为0.62%、0.73%、0.95%;重复性试验中RSD值分别为0.83%、0.97%、0.88%,说明该方法线性关系良好、精密度高、重复性好,可用于体外评价药物制剂在黏液中的渗透性。研究结果表明,利用ATR-FTIR在不同时间内扫描样品可得到不同脂质体制剂样品的强度增加的吸收带。对于不同粒径PEG脂质体而言,粒径越小其黏液渗透性越强;对于不同电荷脂质体而言,壳聚糖脂质体黏液渗透性最弱,海藻酸钠次之,PEG脂质体黏液渗透性最强。进一步研究表明,不同电荷脂质体黏液渗透性的差异源于其与粘蛋白相互作用,该结论可通过分析粘蛋白酰胺Ⅰ带所包含的各二级结构信息得到。综上,基于ATR-FTIR所建立的体外评价方法灵敏简便,可作为多种不同制剂的鼻黏液渗透性的快速测定,经改进后还可用于药物制剂在其他黏液中的渗透性评价,应用前景广阔。 展开更多
关键词 脂质纳米粒 atr-ftir光谱 渗透 鼻黏液
下载PDF
Accuracy analysis of iron content of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum
9
作者 WANG Jingjing CHEN Yanfei 《Baosteel Technical Research》 CAS 2023年第4期35-40,共6页
The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectro... The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy. 展开更多
关键词 X-ray fluorescence spectrometer Lspectrum galvanized coating iron content
下载PDF
Design and calibration of an elliptical crystal spectrometer for the diagnosis of proton-induced x-ray emission(PIXE)
10
作者 方言律 李东彧 +9 位作者 程浩 高原 申泽清 杨童 李昱泽 夏亚东 晏炀 颜莎 林晨 颜学庆 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期220-225,共6页
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur... Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9. 展开更多
关键词 elliptical crystal spectrometer proton-induced x-ray emission applications of laser ion accelera-tion
下载PDF
Evaluation of Uncertainty in Determination of Ethyl Maltol in Vegetable Oil by Ultra-high Performance Liquid Chromatograph-Mass Spectrometer(UPLC-MS)
11
作者 Lei ZHANG 《Agricultural Biotechnology》 CAS 2023年第3期113-115,共3页
[Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematica... [Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematical model of uncertainty was established by analyzing the method for determining ethyl maltol using UPLC-MS.The sources of uncertainty were analyzed,and the components of uncertainty were calculated to evaluate the expanded uncertainty of the method.[Results]When the content of ethyl maltol in edible vegetable oil was 1657μg/kg,the expanded uncertainty was 22.4μg/kg(K=2,P=95%).[Conclusions]The uncertainty in this evaluation model mainly came from standard solution preparation,sample weighing,dilution of sample to constant volume,standard curve fitting,and repeated measurement. 展开更多
关键词 Ultra-high performance liquid chromatograph-mass spectrometer DETERMINATION Ethyl maltol Uncertainty
下载PDF
Separation of Ions from Volatile Organic Compounds Using High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometer 被引量:2
12
作者 李华 王晓浩 +2 位作者 唐飞 杨吉 丁力 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第2期125-132,I0001,共9页
A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte... A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized. 展开更多
关键词 High-field asymmetric waveform ion mobility spectrometry Mass spectrometer Ion-filter Ion-molecular reaction Proton transfer
下载PDF
Fourier Spectrometer based on Wide-range and Phase-locked Michelson Interferometer with Femtosecond Laser Excitation
13
作者 王自鑫 谢向生 +1 位作者 邓俊祺 周建英 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第1期1-4,I0001,共5页
A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high si... A wide-range and phase-locked Michelson interferometer technique is described. This technique combined with femtosecond laser is used to measure the spectrum of the rare-earth ion Nd:YVO4, which presents very high signal to noise ratio of interferometric intensity output and higher spectral resolution than traditional grating spectrophotometer. 展开更多
关键词 Wide-ranged and phase-locked Michelson interferometer Fourier spectrometer Femtosecond laser High signal to noise ratio High resolution
下载PDF
Factors Influencing the Electron Yield of Needle-Ring Pulsed Corona Discharge Electron Source for Negative Ion Mobility Spectrometer 被引量:4
14
作者 刘欣 李胜利 李铭书 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1215-1220,共6页
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron... A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source. 展开更多
关键词 ion mobility spectrometer electron source pulsed corona discharge effectiveelectrons simulation
下载PDF
ATR-FTIR光谱法检测花生油、芝麻油和菜籽油中的过氧化物
15
作者 赵莹莹 沈悦芳 《实验与分析》 2023年第2期32-36,共5页
食用油在加工和储存过程中脂质易被氧化生成过氧化物,从而影响其营养价值和感官,并会产生毒素诱导多种人类疾病。基于食用油中过氧化物与三苯基膦(TPP)间1:1的定量反应,通过测定反应产物三苯基氧膦(TPPO)于542 cm-1处的红外特征吸收峰,... 食用油在加工和储存过程中脂质易被氧化生成过氧化物,从而影响其营养价值和感官,并会产生毒素诱导多种人类疾病。基于食用油中过氧化物与三苯基膦(TPP)间1:1的定量反应,通过测定反应产物三苯基氧膦(TPPO)于542 cm-1处的红外特征吸收峰,建立检测不同食用油过氧化值的方法。实验结果表明,花生油、芝麻油和菜籽油中的三苯基氧膦(TPPO)在542 cm^(-1)处的特征吸收的峰高D(542)与其过氧化值之间存在良好的线性关系,且线性关系均不同,线性方程分别为y=3.09×10^(-4)x+1.43×10^(-4),R^(2)为0.9918,y=8.23×10^(-4)x-2.86×10^(-4),R2为0.9941,y=5.2×10^(-4)x-3.33×10^(-4),R^(2)为0.9955。建立的方法可以更加准确地检测不同食用油中的过氧化值,且使用的有机溶剂较少,可用于花生油、芝麻油和菜籽油快速、准确的质量控制分析。 展开更多
关键词 花生油 芝麻油 菜籽油 过氧化值 atr-ftir
下载PDF
A Satellite-borne Miniature Ion Mass Spectrometer for Space Plasma 被引量:2
16
作者 KONG Linggao ZHANG Aibing +7 位作者 ZHENG Xiangzhi AN Yaya WANG Wenjing TIAN Zhen GUAN Yibing LIU Chao DING Jianjing SUN Yueqiang 《空间科学学报》 CAS CSCD 北大核心 2015年第6期755-762,共8页
The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical ... The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical electrostatic analyzer accompanied with a Time of Flight(TOF)unit based on ultrathin carbon foil to measure the energy spectra and composition of space plasma.The Time of Flight technique has been used broadly in space plasma measurement.A new type of miniature method for the ion mass spectrometer is introduced.The total mass of the instrument is1.8 kg and the total power consumption is 2.0 W.The calibration results show that the energy measurement range is 8.71~43550eV,the energy resolution is 1.86%and the ion mass from 1 amu(1 amu= 1.67 × 10^(-27)kg) to 58 amu can be resolved by the miniature mass spectrometer.The miniature ion mass spectrometer also has a potential to be increased in the field of view by an electrostatic deflecting system to extend its application in space plasma detection.The miniature ion mass spectrometer has been selected for pre-study of Chinese Strategic Priority Research Program on Space Science. 展开更多
关键词 Satellite-borne MINIATURE MASS spectrometer Space
下载PDF
Characterization of Organic Aerosols in Beijing Using an Aerodyne High-Resolution Aerosol Mass Spectrometer 被引量:3
17
作者 ZHANG Junke WANG Yuesi +3 位作者 HUANG Xiaojuan LIU Zirui JI Dongsheng SUN Yang 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2015年第6期877-888,共12页
Fine particle of organic aerosol (OA), mostly arising from pollution, are abundant in Beijing. To achieve a better un- derstanding of the difference in OA in summer and autumn, a high-resolution time-of-flight aeros... Fine particle of organic aerosol (OA), mostly arising from pollution, are abundant in Beijing. To achieve a better un- derstanding of the difference in OA in summer and autumn, a high-resolution time-of-flight aerosol mass spectrometer (HR- ToF-AMS, Aerodyne Research Inc., USA) was deployed in urban Beijing in August and October 2012. The mean OA mass concentration in autumn was 30 4-30 μg m-3, which was higher than in summer (13 4-6.9 μg m-3). The elemental anal- ysis found that OA was more aged in summer (oxygen-to-carbon (O/C) ratios were 0.41 and 0.32 for summer and autumn, respectively). Positive matrix factorization (PMF) analysis identified three and five components in summer and autumn, re- spectively. In summer, an oxygenated OA (OOA), a cooking-emission-related OA (COA), and a hydrocarbon-like OA (HOA) were indentified. Meanwhile, the OOA was separated into LV-OOA (low-volatility OOA) and SV-OOA (semi-volatile OOA); and in autumn, a nitrogen-containing OA (NOA) was also found. The SOA (secondary OA) was always the most important OA component, accounting for 55% of the OA in the two seasons. Back trajectory clustering analysis found that the origin of the air masses was more complex in summer. Southerly air masses in both seasons were associated with the highest OA loading, while northerly air masses were associated with the lowest OA loading. A preliminary study of OA components, especially the POA (primary OA), in different periods found that the HOA and COA all decreased during the National Day holiday period, and HOA decreased at weekends compared with weekdays. 展开更多
关键词 organic aerosol aerosol mass spectrometer positive matrix factorization seasonal difference
下载PDF
Correction and verification of HL-2A Tokamak Bonner sphere spectrometer in monoenergetic neutron fields from 100 keV to 5 MeV 被引量:2
18
作者 Bo-Wen Zheng Chun-Yu Jiang +4 位作者 Zi-Hao Liu Yin-Hai Pan Xian-Ying Song Shi-Biao Tang Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期72-82,共11页
A real-time Bonner sphere spectrometer(BSS)has been developed for spectral neutron measurements with the HL-2A Tokamak.To correct and verify the accuracy of the neutron spectrum from the BSS,the BSS system was calibra... A real-time Bonner sphere spectrometer(BSS)has been developed for spectral neutron measurements with the HL-2A Tokamak.To correct and verify the accuracy of the neutron spectrum from the BSS,the BSS system was calibrated using monoenergetic neutron beams in the energy range of 100 keV–5 MeV.The response function of the BSS was corrected based on the calibration results,and the corrected BSS system was verified by unfolding monoenergetic neutron spectra.Fusion neutron spectra on the HL-2A have been obtained from the calibrated BSS system for the first time. 展开更多
关键词 Bonner SPHERE spectrometer Calibration Response function NEUTRON spectrometRY
下载PDF
Development of the real-time double-ring fusion neutron time-of-flight spectrometer system at HL-2M 被引量:2
19
作者 Bo-Wen Zheng Wei Zhang +5 位作者 Tong-Yu Wu Si-Cheng Huang Yi-Po Zhang Xiu-Feng Xu Shi-Biao Tang Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第12期22-30,共9页
A real-time double-ring neutron time-of-flight(TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high count rate and sufficient energy resolution.The TOFII sys... A real-time double-ring neutron time-of-flight(TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high count rate and sufficient energy resolution.The TOFII system is in its development stage,and this work describes its characteristics in terms of design principle,system structure,electronic system design,preliminary tests,and neutron transport simulation.The preliminary test results illustrate that the TOFII system can demonstrate the realtime dynamic spectrum every 10 ms.The results also show that based on the support vector machine method,the n-γ discrimination algorithm achieves the discrimination accuracy of 99.1%with a figure of merit of 1.30,and the intrinsic timing resolution of the system is within 0.3%.The simulated flight time spectrums from 1 to 5 MeV are obtained through the Monte Carlo tool Geant4,which also provide the reasonable results.The TOFII system will then be calibrated on mono-energetic neutron sources for further verification. 展开更多
关键词 Time-of-light NEUTRON spectrometer GEANT4 HL-2M
下载PDF
A real-time neutron-gamma discriminator based on the support vector machine method for the time-of-flight neutron spectrometer 被引量:3
20
作者 张伟 吴彤宇 +3 位作者 郑博文 李世平 张轶泼 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第4期170-175,共6页
A new neutron-gamma discriminator based on the support vector machine(SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintil... A new neutron-gamma discriminator based on the support vector machine(SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintillator with pulse-shape discrimination(PSD) property. The SVM algorithm is implemented in field programmable gate array(FPGA) to carry out the real-time sifting of neutrons in neutron-gamma mixed radiation fields. This study compares the ability of the pulse gradient analysis method and the SVM method. The results show that this SVM discriminator can provide a better discrimination accuracy of 99.1%. The accuracy and performance of the SVM discriminator based on FPGA have been evaluated in the experiments. It can get a figure of merit of 1.30. 展开更多
关键词 plasma diagnosis support vector machine pulse-shape discrimination TOF spectrometer
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部