Determining the Effect of Acute Abdominal Pain Using Ultrasound
1
作者 Mona Elhaj 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2023年第1期9-16,共8页
Acute abdominal pain is a medical emergency that is characterized by abrupt, acute, recently developed abdominal pain that is accompanied by other signs that are confined in the abdomen area. The purpose of this study... Acute abdominal pain is a medical emergency that is characterized by abrupt, acute, recently developed abdominal pain that is accompanied by other signs that are confined in the abdomen area. The purpose of this study was to illustrate how ultrasonography may be used to identify sudden abdominal pain. From December 2021 and March 2022, a comprehensive examination of 50 patients with acute abdominal pain was conducted. Seven hospitals in Khartoum State, Sudan, examined individuals with clinically suspected abdominal and pelvic deformities using 3.5 MHz ultrasound machines. Out of the 50 (100%) patients who were presented with acute abdominal pain 10 (20%) were appendicitis, 9 (18%) were cholecystitis, 8 (16%) were Nephrolithiasis, 3 (6%) were Choledocholithiasis, 3 (6%) were Chronic kidney disease, 3 (6%) were Cholelithiasis, 3 (6%) were Cystitis, 4 (8%) were Ascites, 1 (2%) was acute kidney injury, 1 (2%) was Acute Peritonitis, 1 (2%) was Diverticulum and 1 (2%) each was of Epigastric hernia, Hepatosplenomegaly, Liver cirrhosis, Nephritis and Ovarian cysts respectively. According to the study results, ultrasonography (US) proceeds to be the go-to imaging strategy in most situations, particularly for younger and female patients, where limiting exposure to radiation must be obligated. The application of Computerized Tomography CT should be restricted in circumstances where there is no diagnostic US and, in all situations, where there is a significant disparity between medical symptoms and negative imaging in the US. 展开更多
关键词 ultrasound abdominal Pain EMERGENCY
下载PDF
Predictive value of the trans-perineal three-dimensional ultrasound measurement of the pubic arch angle for vaginal delivery
2
作者 Zhu-Wei Liang Wan-Li Gao 《World Journal of Clinical Cases》 SCIE 2023年第20期4874-4882,共9页
BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distrib... BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA. 展开更多
关键词 three-dimensional ultrasound Subpubic arch angle Trans-perineal Vaginal delivery
下载PDF
Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors 被引量:14
3
作者 Jian-Jun Li Guo-Liang Xu +4 位作者 Mo-Fa Gu Guang-Yu Luo Zhang Rong Pei-Hong Wu Jian-Chuan Xia 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第19期2747-2751,共5页
AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with re... AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with recurrent and metastatic abdominal tumors were enrolled in this study. Real-time sonography was taken, and vital signs, liver and kidney function, skin burns, local reactions, and systemic effects were observed and recored before, during, and after HIFU. CT and MR/were also taken before and after HIFU. RESULTS: All 17 patients had skin burns and pain in the treatment region; the next common complication was neurapraxia of the stomach and intestines to variable degrees. The other local and systemic complications were relatively rare. Severe complications were present in two patients; one developed a superior mesenteric artery infarction resulting in necrosis of the entire small intestines, and the other one suffered from a perforation in terminal ileum due to HIFU treatment. CONCLUSION: Although HIFU is a one of noninvasive treatments for the recurrent and metastatic abdominal tumors, there are still some common and severe complications which need serious consideration. 展开更多
关键词 abdominal cavity RECURRENT METASTATIC TUMOR High intensity focused ultrasound Ultrasonic therapy
下载PDF
Fatty liver disease in severe obese patients:Diagnostic value of abdominal ultrasound 被引量:10
4
作者 Alessandro de Moura Almeida Helma Pinchemel Cotrim +6 位作者 Daniel Batista Valente Barbosa Luciana Gordilho Matteoni de Athayde Adimeia Souza Santos Almir Galvo Vieira Bitencourt Luiz Antonio Rodrigues de Freitas Adriano Rios Erivaldo Alves 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第9期1415-1418,共4页
AIM:To evaluate the sensitivity and specificity of abdominal ultrasound (US) for the diagnosis of hepatic steatosis in severe obese subjects and its relation to histological grade of steatosis. METHODS: A consecutive ... AIM:To evaluate the sensitivity and specificity of abdominal ultrasound (US) for the diagnosis of hepatic steatosis in severe obese subjects and its relation to histological grade of steatosis. METHODS: A consecutive series of obese patients, who underwent bariatric surgery from October 2004 to May 2005, was selected. Ultrasonography was performed in all patients as part of routine preoperative time and an intraoperative wedge biopsy was obtained at the beginning of the bariatric surgery. The US and histological findings of steatosis were compared, considering histology as the gold standard. RESULTS: The study included 105 patients. The mean age was 37.2 ± 10.6 years and 75.2% were female. The histological prevalence of steatosis was 89.5%. The sensitivity and specificity of US in the diagnosis of hepatic steatosis were, respectively, 64.9% (95% CI: 54.9-74.3) and 90.9% (95% CI: 57.1-99.5). The positive predictive value and negative predictive value were, respectively, 98.4% (95% CI: 90.2-99.9) and 23.3% (95% CI: 12.3-39.0). The presence of steatosis onUS was associated to advanced grades of steatosis on histology (P = 0.016). CONCLUSION: Preoperative abdominal US in our series has not shown to be an accurate method for the diagnosis of hepatic steatosis in severe obese patients. Until another non-invasive method demonstrates better sensitivity and specificity values, histological evaluation may be recommended to these patients undergoing bariatric surgery. 展开更多
关键词 Bariatric surgery OBESITY Hepatic steatosis abdominal ultrasound diagnosis Fatty liver
下载PDF
Intraoperative abdominal ultrasound in oncologic imaging 被引量:4
5
作者 Leonardo P Marcal Madhavi Patnana +1 位作者 Priya Bhosale Deepak G Bedi 《World Journal of Radiology》 CAS 2013年第3期51-60,共10页
Significant advances in ultrasound technology have created new opportunities for its use in oncologic imaging. The advent of new transducers with focal beam technology and higher frequency has solidified the role of i... Significant advances in ultrasound technology have created new opportunities for its use in oncologic imaging. The advent of new transducers with focal beam technology and higher frequency has solidified the role of intraoperative sonography (IOUS) as an invaluable imaging modality in oncologic surgery of the liver, kidneys and pancreas. The ability to detect and characterize small lesions and the precise intraoperative localization of such tumors is essential for adequate surgical planning in segmental or lobar hepatic resections, metastasectomy, nephron-sparing surgery, and partial pancreatectomy. Also, diagnostic characterization of small equivocal lesions deemed indeterminate by conventional preoperative imaging such as multidetector computed tomography or magnetic resonance imaging, has become an important application of IOUS. This article will review the current applications of IOUS in the liver, kidneys and pancreas. 展开更多
关键词 abdominal ultrasound Oncologic IMAGING
下载PDF
Role of three-dimensional endoanal ultrasound in assessing the anal sphincter morphology of female patients with chronic proctalgia 被引量:9
6
作者 Ya-Hong Xue Shu-Qing Ding +1 位作者 Yi-Jiang Ding Li-Qun Pan 《World Journal of Gastroenterology》 SCIE CAS 2017年第21期3900-3906,共7页
AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control stud... AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control study, 30 consecutive female patients with CP and 25 normal women (control group) were enrolled. 3D-EAUS was performed in all subjects. Thickness and length of internal anal sphincter (IAS), thickness of puborectalis muscle (PR), length of the external anal sphincter (EAS) plus PR, and puborectalis angle were measured and compared between the two groups. RESULTS Patients with CP had significantly shorter IAS length and greater PR thickness, as compared to those in normal individuals (26.28 +/- 3.59 mm vs 28.87 +/- 4.84 mm, P < 0.05 and 9.67 +/- 1.57 mm vs 8.85 +/- 0.97 mm, P < 0.05, respectively). No significant between-group differences were observed with respect to IAS thickness and the EAS plus PR length (P > 0.05). Puborectalis angle in the CP group was significantly decreased, both in resting (88.23 degrees +/- 1.81 degrees vs 89.94 degrees +/- 2.07 degrees in control group, P < 0.05) and straining (88.47 degrees +/- 3.32 degrees vs 90.72 degrees +/- 1.87 degrees in control group, P < 0.05) phases, which suggest the presence of paradoxical contraction of PR in patients with CP. In the CP group, no significant difference in puborectalis angle was observed between the resting and straining phases (88.23 degrees +/- 1.81 degrees vs 88.47 degrees +/- 3.32 degrees respectively, P > 0.05). CONCLUSION The association of greater PR thickness and paradoxical contraction of PR with CP suggest their potential value as markers of CP. 展开更多
关键词 chronic proctalgia three-dimensional endoanal ultrasound puborectalis angle internal anal sphincter puborectalis muscle
下载PDF
Detection of Congenital Uterine Malformation by Using Transvaginal Three-dimensional Ultrasound 被引量:7
7
作者 于利利 张璇 +2 位作者 章婷 陈汉荣 王泽华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第5期782-784,共3页
This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congen... This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly. 展开更多
关键词 congenital uterine malformation transvaginal three-dimensional ultrasound coronary plane
下载PDF
Accuracy of abdominal ultrasound for the diagnosis of small bowel obstruction in the emergency department 被引量:5
8
作者 Sarah E. Frasure Amy F. Hildrcth +1 位作者 Raghu Seethala Heidi H. Kimberly 《World Journal of Emergency Medicine》 SCIE CAS 2018年第4期267-271,共5页
BACKGROUND: Emergency physicians frequently encounter patients with acute small bowel obstructions (SBO). Although computed tomography (CT) imaging is the current gold standard in the assessment of patients with ... BACKGROUND: Emergency physicians frequently encounter patients with acute small bowel obstructions (SBO). Although computed tomography (CT) imaging is the current gold standard in the assessment of patients with suspected SBO in the emergency department, a few studies have examined the use of ultrasound as an alternative imaging technique. METHODS: We evaluated the accuracy of ultrasound performed in the ED by a variety of providers (physicians with various levels of training, physician assistants) compared to CT imaging in 47 patients with suspected SBOs. RESULTS: Our data demonstrated a sensitivity of 93.8% and a specificity of 93.3% when compared to abdominal CT, and a sensitivity of 94.3% and specificity of 95.2% using a composite endpoint of abdominal CT and discharge diagnosis. CONCLUSION: Ultrasound can play an important role in the identification of small bowe obstructions in ED patients. 展开更多
关键词 abdominal ultrasound Small bowel obstruction Emergency department
下载PDF
Influence of the abdominal wall on the nonlinear propagation of focused therapeutic ultrasound 被引量:2
9
作者 刘振波 范庭波 +1 位作者 章东 龚秀芬 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第11期4932-4937,共6页
This article theoretically studies the influence of inhomogeneous abdominal walls on focused therapeutic ultrasound based on the phase screen model. An inhomogeneous tissue is considered as a combination of a homogene... This article theoretically studies the influence of inhomogeneous abdominal walls on focused therapeutic ultrasound based on the phase screen model. An inhomogeneous tissue is considered as a combination of a homogeneous medium and a phase aberration screen. Variations of acoustic parameters such as peak positive pressure, peak negative pressure, and acoustic intensity are discussed with respect to the phase screen statistics of human abdominal walls. Results indicate that the abdominal wall can result in energy loss of the sound in the focal plane. For a typical human abdominal wall with correlation length of 7.9 mm and variance of 0.36, the peak acoustic intensity radiated from a 1MHz transmitter with a radius of 30 mm can be reduced by about 14% at the focal plane. 展开更多
关键词 phase aberration focused therapeutic ultrasound abdominal wall
下载PDF
The importance of visualization of appendix on abdominal ultrasound for the diagnosis of appendicitis in children: A quality assessment review 被引量:2
10
作者 Muhammad Akhter Hamid Ruqiya Afroz +4 位作者 Uqba Nawaz Ahmed Aneela Bawani Dilnasheen Khan Rabia Shahab Asim Salim 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2020年第3期140-144,共5页
BACKGROUND:Ultrasound has the first line investigation role in the diagnosis of acute appendicitis in children.The purpose of this study was to perform a quality assessment review on the visualization rate of appendix... BACKGROUND:Ultrasound has the first line investigation role in the diagnosis of acute appendicitis in children.The purpose of this study was to perform a quality assessment review on the visualization rate of appendix on ultrasound in children in the community hospital setting.METHODS:A retrospective chart review of the abdominal ultrasound findings for the visualization of the appendix was performed on paediatric patients ranging from 5 to 18 years.Data were collected from the two community hospitals of Toronto by using hospital electronic medical record for the ultrasound findings in patients presented with abdominal pain.RESULTS:Data from two community hospitals indicated visualization rate of the appendix as 11.0%and 23.2%for site 1 and site 2 respectively.In cases where the ultrasound was repeated the visualization rate remains the same.A two-proportion z-test was performed to find whether the visualization of appendix increases the likelihood of diagnosing appendicitis.The results revealed that the visualization of an appendix(P=0.52),significantly improved the diagnosis of appendicitis(z=34,P<0.001).CONCLUSION:Visualization of an appendix on ultrasound increases the likelihood of correctly diagnosing appendicitis.In our study,we found low visualization rate of appendix on ultrasound that could be the result of many factors that contribute towards the low visualization rate of an appendix on ultrasound.Hence,the challenges in identifying appendix should be minimized to improve the visualization and diagnosis of appendicitis on ultrasound. 展开更多
关键词 abdominal ultrasound VISUALIZATION IMPORTANCE APPENDIX abdominal pain Acute APPENDICITIS CHILDREN Paediatric population
下载PDF
Sequential transcatheter arterial chemoembolization,three-dimensional conformal radiotherapy,and high-intensity focused ultrasound treatment for unresectable hepatocellular carcinoma patients 被引量:9
11
作者 Shengfa Ni Lingxiang Liu Yongqian Shu 《The Journal of Biomedical Research》 CAS 2012年第4期260-267,共8页
The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional c... The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC. 展开更多
关键词 transcatheter arterial chemoembolization(TACE) three-dimensional con-formal radiotherapy(3DCRT) high-intensity focused ultrasound(HIFU) hepatocellular carcinoma
下载PDF
Abdominal pregnancy secondary to iatrogenic uterine perforation: A case report and literature review
12
作者 Yanqing Hao Jianmin Chen Dong Huang 《Laparoscopic, Endoscopic and Robotic Surgery》 2023年第3期119-122,共4页
Abdominal pregnancy is a rare and life-threatening form of ectopic pregnancy.It is defined as an ectopic pregnancy in a region of the peritoneal cavity that does not include the fallopian tubes,ovaries,or their associ... Abdominal pregnancy is a rare and life-threatening form of ectopic pregnancy.It is defined as an ectopic pregnancy in a region of the peritoneal cavity that does not include the fallopian tubes,ovaries,or their associated ligamentous structures.Many abdominal pregnancies are caused by secondary implantation in the peritoneal cavity after tubal abortion,rupture,or uterine rupture.Here,we report a case of abdominal pregnancy resulting from iatrogenic uterine perforation during the induced abortion of an early intrauterine pregnancy,which had been misdiagnosed as a ruptured corpus luteum cyst due to the sudden rupture of the abdominal gestational sac,complicating intra-abdominal hemorrhage.The true diagnosis was missed by vaginal ultrasound and confirmed by laparoscopic exploration.We discuss the details of the case management and review the relevant literature.©2023 Zhejiang University. 展开更多
关键词 abdominal pregnancy Uterine perforation Transvaginal ultrasound LAPAROSCOPY
下载PDF
22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses 被引量:2
13
作者 William Sterlacci Athanasios D Sioulas +10 位作者 Lothar Veits Pervin G?nüllü Guido Schachschal Stefan Groth Mario Anders Christos K Kontos Theodoros Topalidis Andrea Hinsch Michael Vieth Thomas R?sch Ulrike W Denzer 《World Journal of Gastroenterology》 SCIE CAS 2016年第39期8820-8830,共11页
AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included i... AIM To compare the aspiration needle(AN) and core biopsy needle(PC) in endoscopic ultrasound-guided fine needle aspiration(EUS-FNA) of abdominal masses.METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge(G) AN(Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22 G PC(Echo Tip Pro Core; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.RESULTS Fifty six consecutive patients(29 men; mean age 68 years) with pancreatic lesions(n = 38), lymphadenopathy(n = 13), submucosal tumors(n = 4), or others lesions(n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy(AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy(AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes(AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score(AN: 1.7 vs PC: 1.1, P = 0.058), and complications(none). A diagnosis on the basis of histology was achieved in the PC group in 36(64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN(AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle. 展开更多
关键词 Endoscopic ultrasound CYTOLOGY Fine needle aspiration abdominal tumors Core biopsy needle
下载PDF
Automatic Measurement of Fetal Abdominal Biometric Parameters—Feasibility on a Portable Ultrasound Device 被引量:1
14
作者 Naiad Hossain Khan Eva Tegnander +4 位作者 Sigurd Storve Johan Morten Dreier Sturla Eik-Nes Hans Torp Gabriel Kiss 《Open Journal of Obstetrics and Gynecology》 2017年第8期922-936,共15页
An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, t... An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, the location of fetal abdomen is detected by image processing. Thereafter, an active contour model is converged along the abdominal boundary for measurement purposes. The validation data set contained 310 images of fetuses with gestational age (GA) from 14 to 41 weeks. The measurement success rate was 88.1%. By manually indicating the location of the abdomen, the success rate was further improved to 95.8% for the failed cases. The correlation between manual and automatic measurements was 0.95 and the intraclass correlation coefficient (ICC) was 0.976 (95% confidence interval (CI);0.969 - 0.981). The average method execution time was 0.3 s. The mean error was lower in young fetuses (0.4%) than in older fetuses (-2.1%). The proposed cross-platform method was implemented on a portable, low-cost ultrasound machine prototype targeted for low- and middle-income countries (LMIC);the results achieved were comparable to those of other state-of-the-art automatic methods. 展开更多
关键词 Portable ultrasound Scanner AUTOMATIC Measurement Mean abdominal Diameter abdominal CIRCUMFERENCE PRENATAL ultrasound ICT4D
下载PDF
Prenatal Diagnosis of Sirenomelia by Two-Dimensional and Three-Dimensional Skeletal Imaging Ultrasound 被引量:1
15
作者 刘蓉 陈欣林 +1 位作者 杨小红 马慧静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第6期928-931,共4页
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem... Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia. 展开更多
关键词 SIRENOMELIA three-dimensional skeletal imaging ultrasound three-dimensional helicalcomputed tomography
下载PDF
Three-dimensional psychological guidance combined with evidencebased health intervention in patients with liver abscess treated with ultrasound
16
作者 Ya-Nan Shan Ying Yu +2 位作者 Yi-Han Zhao Lian-Lian Tang Xiao-Min Chen 《World Journal of Clinical Cases》 SCIE 2022年第23期8196-8204,共9页
BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis ... BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis is difficult,which may lead to misdiagnosis.AIM To observe the effects of psychological guidance combined with evidence-based health intervention in patients with liver abscess treated with ultrasound.METHODS A total of 120 patients with bacterial liver abscess admitted to our hospital from May 2018 to February 2021 were selected and divided into groups according to their intervention plan.RESULTS After the intervention,Self-Rating Depression Scale,Self-Rating Anxiety Scale,Self-Perceived Burden Scale(SPBS),and quality of life scores(physical functioning,role physical,bodily pain,general health,vitality,social functioning,role emotional,mental health)were lower than before the intervention in the two groups.The observation group had lower negative sentiment,SPBS,and quality of life scores than the control group.In the observation group,31 and 24 patients had good and general compliance,respectively,with a compliance rate of 91.67%,which was significantly higher than that in the control group.The observation group had significantly lower total incidence of incision infection,abdominal abscess,hemorrhage,and severe abdominal pain than the control group.CONCLUSION Three-dimensional psychological guidance combined with evidence-based health intervention in treating liver abscess can reduce patients’burden and negative emotions,improve patient compliance and quality of life,and reduce complications. 展开更多
关键词 three-dimensional psychological guidance Evidence-based health intervention ultrasound intervention Liver abscess Negative emotions COMPLIANCE
下载PDF
Ultrasound-guided percutaneous drainage of a traumatic abdominal wall hematoma in the emergency department
17
作者 Laura Trujillo Sara Naranjo +1 位作者 Alcjandro Cardozo Bryan Alvarez 《World Journal of Emergency Medicine》 CAS 2012年第4期308-310,共3页
BACKGROUND:Abdominal wall hematoma is due to trauma,coagulation disorders or anticoagulation therapy complications.METHODS:in this report we present a case of a 44-year-old female who suffered from blunt abdominal tra... BACKGROUND:Abdominal wall hematoma is due to trauma,coagulation disorders or anticoagulation therapy complications.METHODS:in this report we present a case of a 44-year-old female who suffered from blunt abdominal trauma and presented to the emergency department with sharp abdominal pain and ecchymosis.FAST and abdominal computerized tomography(CT) revealed an abdominal wall hematoma.Treatment with an ultrasound-guided percutaneous drainage was performed successfully.RESULTS:The patient remained under observation for six hours with serial ultrasound scans,and no signs of hematoma recurrence were present.She was discharged the same day with clinical improvement.CONCLUSION:Complete history investigation and clinical examination help to make a correct diagnosis of abdominal wall hematoma,select a prompt treatment,and reduce complications. 展开更多
关键词 Rectus sheath hematoma abdominal wall hematoma Emergency Department FAST ultrasound guided percutaneous drainage
下载PDF
Changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression
18
作者 Ju-Hua Pan Ye-Qing Ren Qing-Lian Ma 《Journal of Hainan Medical University》 2019年第11期69-74,共6页
Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: Th... Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: The patients who were diagnosed with cervical cancer and received neoadjuvant chemotherapy in Wuhan Red Cross Hospital between March 2015 and October 2017 were selected as the cervical cancer group, and the patients who received cervical biopsy and were diagnosed with stage I cervical intraepithelial neoplasia by pathological findings during the same period were selected as the control group. Before biopsy, three-dimensional power Doppler ultrasonography was performed to measure VI, FI and VFI;the tissues of cervical cancer group before and after chemotherapy as well as the biopsy tissues of control group were collected to measure the expression of proliferation genes, invasion genes and angiogenesis genes.Results: The VI, FI and VFI levels as well as the Piwil2 gene (Piwil2), CyclinD1, N-Myc downstream regulated gene 3 (NDRG3), CXC chemokine ligand 5 (CXCL5), cathepsin-L (CAT-L), EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1), angiotensin (Ang)1, Ang2 and angiopoietin-like protein 4 (ANGPTL4) mRNA expression levels in the tissues of cervical cancer group before and after chemotherapy were all significantly higher than those of control group whereas the thrombospondin 2 (THBS2), Smac gene (Smac), large tumor suppressor kinase 1 (LATS1), reversion-inducing-cysteine-rich protein with kazal motifs (RECK) and plas minogen activator inhibitor 1 (PAI-1) mRNA expression levels in the tissues were all significantly lower than those of control group, and the VI, FI and VFI levels as well as the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels in the tissues of cervical cancer group after chemotherapy were all significantly lower than those before chemotherapy whereas the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels were all significantly higher than those before chemotherapy;the VI, FI and VFI levels in cervical cancer tissues were positively correlated with the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels, and negatively correlated with the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels.Conclusion: The changes in the three-dimensional power Doppler ultrasound parameters before and after neoadjuvant chemotherapy for cervical cancer can reflect the changes in proliferation, invasion and angiogenesis gene expression in the lesions. 展开更多
关键词 CERVICAL cancer three-dimensional power Doppler ultrasound Proliferation INVASION ANGIOGENESIS
下载PDF
Value of myocardial function in children with Kawasaki disease by two-dimensional and three-dimensional ultrasound speckle tracking
19
作者 Ya-Mei Shen Tao-Min Bai +4 位作者 Xue-Mei Zhang Chun-Miao Kang Xiao-Ni Chang Yan-Hua Gao Xiao-Hua Yan 《Journal of Hainan Medical University》 2019年第21期58-61,共4页
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met... Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease. 展开更多
关键词 KAWASAKI disease TWO-DIMENSIONAL ultrasound SPECKLE TRACKING three-dimensional ultrasound SPECKLE TRACKING myocardial FUNCTION left ventricular systolic FUNCTION
下载PDF
Correlation analysis of real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis
20
作者 Lin Li Hong-Ying Zhu He-Juan Du 《Journal of Hainan Medical University》 2019年第12期67-70,共4页
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method... Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated. 展开更多
关键词 REAL-TIME three-dimensional ultrasound CIRRHOSIS Left VENTRICULAR FUNCTION Portal HEMODYNAMICS Liver FUNCTION
下载PDF