期刊文献+
共找到1,317篇文章
< 1 2 66 >
每页显示 20 50 100
Efficacy and safety of percutaneous transhepatic biliary radiofrequency ablation in patients with malignant obstructive jaundice 被引量:1
1
作者 Ying Xing Zheng-Rong Liu +1 位作者 You-Guo Li Hong-Yi Zhang 《World Journal of Clinical Cases》 SCIE 2024年第17期2983-2988,共6页
BACKGROUND Percutaneous transhepatic cholangiodrainage(PTCD)and endoscopic retrograde cholangiopancreatography/endoscopic nasobiliary drainage are the most common clinical procedures for jaundice control in patients w... BACKGROUND Percutaneous transhepatic cholangiodrainage(PTCD)and endoscopic retrograde cholangiopancreatography/endoscopic nasobiliary drainage are the most common clinical procedures for jaundice control in patients with unresectable malignant obstructive jaundice,yet the safety and effect of endobiliary radiofrequency ablation(EB-RFA)combined PTCD is rarely reported,in this article,we report our experience of EB-RFA combined PTCD in such patients.AIM To retrospectively study the efficacy and safety of EB-RFA combined PTCD in patients with unresectable malignant obstructive jaundice.METHODS Patients with unresectable malignant obstructive jaundice treated with EB-RFA under PTCD were selected,the bile ducts of the right posterior lobe was selected as the target bile ducts in all cases.The general conditions of all patients,preoperative tumour markers,total bilirubin(TBIL),direct bilirubin(DBIL),albumin(ALB),alkaline phosphatase(ALP),and glutamyl transferase(GGT)before and on the 7th day after the procedure,as well as perioperative complications,stent patency time and patient survival were recorded.RESULTS All patients successfully completed the operation,TBIL and DBIL decreased significantly in all patients at the 7th postoperative day(P=0.009 and 0.006,respectively);the values of ALB,ALP and GGT also decreased compared with the preoperative period,but the difference was not statistically significant.Perioperative biliary bleeding occurred in 2 patients,which was improved after transfusion of blood and other conservative treatments,pancreatitis appeared in 1 patient after the operation,no serious complication and death happened after operation.Except for 3 patients with loss of visits,the stent patency rate of the remaining 14 patients was 100%71%and 29%at the 1^(st),3^(rd),and 6^(th)postoperative months respectively,with a median survival of 4 months.CONCLUSION EB-RFA under PTCD in patients with unresectable malignant obstructive jaundice has a satisfactory therapeutic effect and high safety,which is worthy of further clinical practice. 展开更多
关键词 Biliary tract tumour Malignant obstructive jaundice Percutaneous transhepatic cholangiodrainage Endoluminal radiofrequency ablation Biliary radiofrequency ablation
下载PDF
Nomogram predicting the prognosis of primary liver cancer after radiofrequency ablation combined with transcatheter arterial chemoembolization 被引量:1
2
作者 Hai-Hua Shen Yu-Rong Hong +4 位作者 Wen Xu Lei Chen Jun-Min Chen Zhi-Gen Yang Cai-Hong Chen 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2630-2639,共10页
BACKGROUND The incidence and mortality rates of primary hepatocellular carcinoma(HCC)are high,and the conventional treatment is radiofrequency ablation(RFA)with transcatheter arterial chemoembolization(TACE);however,t... BACKGROUND The incidence and mortality rates of primary hepatocellular carcinoma(HCC)are high,and the conventional treatment is radiofrequency ablation(RFA)with transcatheter arterial chemoembolization(TACE);however,the 3-year survival rate is still low.Further,there are no visual methods to effectively predict their prognosis.AIM To explore the factors influencing the prognosis of HCC after RFA and TACE and develop a nomogram prediction model.METHODS Clinical and follow-up information of 150 patients with HCC treated using RFA and TACE in the Hangzhou Linping Hospital of Traditional Chinese Medicine from May 2020 to December 2022 was retrospectively collected and recorded.We examined their prognostic factors using multivariate logistic regression and created a nomogram prognosis prediction model using the R software(version 4.1.2).Internal verification was performed using the bootstrapping technique.The prognostic efficacy of the nomogram prediction model was evaluated using the concordance index(CI),calibration curve,and receiver operating characteristic RESULTS Of the 150 patients treated with RFA and TACE,92(61.33%)developed recurrence and metastasis.Logistic regression analysis identified six variables,and a predictive model was created.The internal validation results of the model showed a CI of 0.882.The correction curve trend of the prognosis prediction model was always near the diagonal,and the mean absolute error before and after internal validation was 0.021.The area under the curve of the prediction model after internal verification was 0.882[95%confidence interval(95%CI):0.820-0.945],with a specificity of 0.828 and sensitivity of 0.656.According to the Hosmer-Lemeshow test,χ^(2)=3.552 and P=0.895.The predictive model demonstrated a satisfactory calibration,and the decision curve analysis demonstrated its clinical applicability.CONCLUSION The prognosis of patients with HCC after RFA and TACE is affected by several factors.The developed prediction model based on the influencing parameters shows a good prognosis predictive efficacy. 展开更多
关键词 NOMOGRAM Primary liver cancer Radiofrequency ablation Transcatheter arterial chemoembolization PROGNOSIS Influencing factors Decision curve analysis
下载PDF
Nano-silica modified lightweight and high-toughness carbon fiber/phenolic ablator with excellent thermal insulation and ablation performance
3
作者 Wenjie Xu Wenda Song +4 位作者 Xianfeng Jia Cheng Ma Jitong Wang Wenming Qiao Licheng Ling 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期192-199,共8页
Lightweight and high-toughness carbon fiber/phenolic ablator(CFPA)is required as the Thermal Protection System(TPS)material of aerospace vehicles for next-generation space missions.To improve the ablative properties,s... Lightweight and high-toughness carbon fiber/phenolic ablator(CFPA)is required as the Thermal Protection System(TPS)material of aerospace vehicles for next-generation space missions.To improve the ablative properties,silica sol with good particle size distribution prepared using tetramethoxysilane(TMOS)was blended with natural rubber latex and deposited onto carbon fiber felt,which was then integrated with phenolic aerogel matrix,introducing nano-silica into the framework of CFPA.The modified CFPA with a low density of 0.28—0.31 g/cm3exhibits strain-in-fracture as high as 31.2%and thermal conductivity as low as 0.054 W/(m·K).Furthermore,a trace amount of nano-silica could effectively protect CFPA from erosion of oxidizing atmosphere in different high-temperature environments.The oxyacetylene ablation test of 3000°C for 20 s shows a mass ablation rate of 0.0225 g/s,a linear ablation rate of 0.209 mm/s for the modified CFPA,which are 9.64%and 24.82%lower than the unmodified one.Besides,the long-time butane ablation test of 1200°C for 200 s shows an insignificant recession with mass and linear ablation rate of 0.079 g/s and 0.039 mm/s,16.84%and 13.33%lower than the unmodified one.Meanwhile,the fixed thermocouple in the test also demonstrates a good thermal insulation performance with a low peak back-face temperature of 207.7°C,12.25%lower than the unmodified one.Therefore,the nano-silica modified CFPA with excellent overall performance presents promising prospects in high-temperature aerospace applications. 展开更多
关键词 NANO-SILICA Carbonfiber Phenolic aerogel Insulation ablation
下载PDF
Microstructure and ablation behavior of Zr-based ultra-high-temperature gradient composites
4
作者 Qing-hua LIU Tian TIAN +2 位作者 Wei SUN Hong-bo ZHANG Xiang XIONG 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2024年第9期2889-2899,共11页
To obtain high-performance Zr-based ultra-high-temperature composites,Zr-based ultra-high-temperature gradient composites were prepared by changing the laying method of the infiltrant via reactive melt infiltration.Th... To obtain high-performance Zr-based ultra-high-temperature composites,Zr-based ultra-high-temperature gradient composites were prepared by changing the laying method of the infiltrant via reactive melt infiltration.The effects of different infiltrant laying methods on the microstructure and ablative properties of Zr-based ultrahigh-temperature gradient composites were investigated.The results showed that the gradient structure of the Zr-based ultrahigh-temperature gradient composites differed when the composition ratio of the infiltrant was changed.When the thicknesses of the Zr/Mo/Si layers were 6/4/12 mm and 8/2/12 mm,the SiMoZrC solid solution content in the samples increased and decreased along the infiltration direction,respectively.The gradient samples were ablated in an oxyacetylene flame at 3000°C for 40 s.The ablation resistance of the sample was the highest when the infiltrant was a powder and the thickness of the Zr/Mo/Si layer was 6/4/12 mm. 展开更多
关键词 reactive melt infiltration ceramic-matrix composites gradient material MICROSTRUCTURE ablation property
下载PDF
Effect of sample temperature on femtosecond laser ablation of copper
5
作者 党伟杰 陈雨桐 +1 位作者 陈安民 金明星 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期377-385,共9页
We conduct an experimental study supported by theoretical analysis of single laser ablating copper to investigate the interactions between laser and material at different sample temperatures,and predict the changes of... We conduct an experimental study supported by theoretical analysis of single laser ablating copper to investigate the interactions between laser and material at different sample temperatures,and predict the changes of ablation morphology and lattice temperature.For investigating the effect of sample temperature on femtosecond laser processing,we conduct experiments on and simulate the thermal behavior of femtosecond laser irradiating copper by using a two-temperature model.The simulation results show that both electron peak temperature and the relaxation time needed to reach equilibrium increase as initial sample temperature rises.When the sample temperature rises from 300 K to 600 K,the maximum lattice temperature of the copper surface increases by about 6500 K under femtosecond laser irradiation,and the ablation depth increases by 20%.The simulated ablation depths follow the same general trend as the experimental values.This work provides some theoretical basis and technical support for developing femtosecond laser processing in the field of metal materials. 展开更多
关键词 femtosecond laser two-temperature model sample temperature ablation depth
下载PDF
Simulation of deuterium pellet ablation and deposition in the EAST tokamak with HPI2 code
6
作者 李大正 张洁 +2 位作者 侯吉磊 李懋 孙继忠 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期561-569,共9页
Pellet injection is a primary method for fueling the plasma in magnetic confinement devices.For that goal the knowledges of pellet ablation and deposition profiles are critical.In the present study,the pellet fueling ... Pellet injection is a primary method for fueling the plasma in magnetic confinement devices.For that goal the knowledges of pellet ablation and deposition profiles are critical.In the present study,the pellet fueling code HPI2 was used to predict the ablation and deposition profiles of deuterium pellets injected into a typical H-mode discharge on the EAST tokamak.Pellet ablation and deposition profiles were evaluated for various pellet injection locations,with the aim at optimizing the pellet injection to obtain a deep fueling depth.In this study,we investigate the effect of the injection angle on the deposition depth of the pellet at different velocities and sizes.The ablation and deposition of the injected pellet are mainly studied at each injection position for three different injection angles:0°,45°,and 60°.The pellet injection on the high field side(HFS)can achieve a more ideal deposition depth than on the low field side(LFS).Among these angles,horizontal injection on the middle plane is relatively better on either the HFS or the LFS.When the injection location is 0.468 m below the middle plane on the HFS or 0.40 m above the middle plane of the LFS,it can achieve a similar deposition depth to the one of its corresponding side.When the pre-cooling effect is taken into account,the deposition depth is predicted to increase only slightly when the pellet is launched from the HFS.The findings of this study will serve as a reference for the update of pellet injection systems for the EAST tokamak. 展开更多
关键词 pellet injection pellet ablation HPI2 pellet deposition
下载PDF
Efficacy of radiofrequency ablation combined with sorafenib for treating liver cancer complicated with portal hypertension and prognostic factors
7
作者 Li-Min Yang Hong-Juan Wang +4 位作者 Shan-Lin Li Guan-Hua Gan Wen-Wen Deng Yong-Sheng Chang Lian-Feng Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第11期1533-1544,共12页
BACKGROUND Patients with liver cancer complicated by portal hypertension present complex challenges in treatment.AIM To evaluate the efficacy of radiofrequency ablation in combination with sorafenib for improving live... BACKGROUND Patients with liver cancer complicated by portal hypertension present complex challenges in treatment.AIM To evaluate the efficacy of radiofrequency ablation in combination with sorafenib for improving liver function and its impact on the prognosis of patients with this condition.METHODS Data from 100 patients with liver cancer complicated with portal hypertension from May 2014 to March 2019 were analyzed and divided into a study group(n=50)and a control group(n=50)according to the treatment regimen.The research group received radiofrequency ablation(RFA)in combination with sorafenib,and the control group only received RFA.The short-term efficacy of both the research and control groups was observed.Liver function and portal hypertension were compared before and after treatment.Alpha-fetoprotein(AFP),glypican-3(GPC-3),and AFP-L3 levels were compared between the two groups prior to and after treatment.The occurrence of adverse reactions in both groups was observed.The 3-year survival rate was compared between the two groups.Basic data were compared between the survival and non-surviving groups.To identify the independent risk factors for poor prognosis in patients with liver cancer complicated by portal hypertension,multivariate logistic regression analysis was employed.RESULTS When comparing the two groups,the research group's total effective rate(82.00%)was significantly greater than that of the control group(56.00%;P<0.05).Following treatment,alanine aminotransferase and aspartate aminotransferase levels increased,and portal vein pressure decreased in both groups.The degree of improvement for every index was substantially greater in the research group than in the control group(P<0.05).Following treatment,the AFP,GPC-3,and AFP-L3 levels in both groups decreased,with the research group having significantly lower levels than the control group(P<0.05).The incidence of diarrhea,rash,nausea and vomiting,and fatigue in the research group was significantly greater than that in the control group(P<0.05).The 1-,2-,and 3-year survival rates of the research group(94.00%,84.00%,and 72.00%,respectively)were significantly greater than those of the control group(80.00%,64.00%,and 40.00%,respectively;P<0.05).Significant differences were observed between the survival group and the non-surviving group in terms of Child-Pugh grade,history of hepatitis,number of tumors,tumor size,use of sorafenib,stage of liver cancer,histological differentiation,history of splenectomy and other basic data(P<0.05).Logistic regression analysis demonstrated that high Child-Pugh grade,tumor size(6–10 cm),history of hepatitis,no use of sorafenib,liver cancer stage IIIC,and previous splenectomy were independent risk factors for poor prognosis in patients with liver cancer complicated with portal hypertension(P<0.05).CONCLUSION Patients suffering from liver cancer complicated by portal hypertension benefit from the combination of RFA and sorafenib therapy because it effectively restores liver function and increases survival rates.The prognosis of patients suffering from liver cancer complicated by portal hypertension is strongly associated with factors such as high Child-Pugh grade,tumor size(6-10 cm),history of hepatitis,lack of sorafenib use,liver cancer at stage IIIC,and prior splenectomy. 展开更多
关键词 Radiofrequency ablation SORAFENIB Liver cancer Portal hypertension EFFICACY Prognosis analysis
下载PDF
Ablation behaviour and mechanical performance of ZrB_(2)-ZrC-SiC modified carbon/carbon composites prepared by vacuum infiltration combined with reactive melt infiltration
8
作者 ZHANG Jia-ping SU Xiao-xuan +2 位作者 LI Xin-gang WANG Run-ning FU Qian-gang 《新型炭材料(中英文)》 SCIE EI CAS CSCD 北大核心 2024年第4期633-644,共12页
The development of advanced aircraft relies on high performance thermal-structural materials,and carbon/carbon com-posites(C/C)composited with ultrahigh-temperature ceramics are ideal candidates.However,the traditiona... The development of advanced aircraft relies on high performance thermal-structural materials,and carbon/carbon com-posites(C/C)composited with ultrahigh-temperature ceramics are ideal candidates.However,the traditional routes of compositing are either inefficient and expensive or lead to a non-uniform distribution of ceramics in the matrix.Compared with the traditional C/C-ZrC-SiC composites prepared by the reactive melt infiltration of ZrSi_(2),C/C-ZrB_(2)-ZrC-SiC composites prepared by the vacuum infiltration of ZrB_(2) combined with reactive melt infiltration have the higher content and more uniform distribution of the introduced ceramic phases.The mass and linear ablation rates of the C/C-ZrB_(2)-ZrC-SiC composites were respectively 68.9%and 29.7%lower than those of C/C-ZrC-SiC composites prepared by reactive melt infiltration.The ablation performance was improved because the volatilization of B_(2)O_(3),removes some of the heat,and the more uniformly distributed ZrO_(2),that helps produce a ZrO2-SiO2 continu-ous protective layer,hinders oxygen infiltration and decreases ablation. 展开更多
关键词 C/C composites ZrB_(2)-ZrC-SiC Vacuum filtration Reactive melt infiltration ablation.
下载PDF
Subpicosecond laser ablation behavior of a magnesium target and crater evolution:Molecular dynamics study and experimental validation
9
作者 江国龙 周霞 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期613-622,共10页
The micro-ablation processes and morphological evolution of ablative craters on single-crystal magnesium under subpicosecond laser irradiation are investigated using molecular dynamics(MD) simulations and experiments.... The micro-ablation processes and morphological evolution of ablative craters on single-crystal magnesium under subpicosecond laser irradiation are investigated using molecular dynamics(MD) simulations and experiments.The simulation results exhibit that the main failure mode of single-crystal Mg film irradiated by a low fluence and long pulse width laser is the ejection of surface atoms,which has laser-induced high stress.However,under high fluence and short pulse width laser irradiation,the main damage mechanism is nucleation fracture caused by stress wave reflection and superposition at the bottom of the film.In addition,Mg[0001] has higher pressure sensitivity and is more prone to ablation than Mg[0001].The evolution equation of crater depth is established using multi-pulse laser ablation simulation and verified by experiments.The results show that,under multiple pulsed laser irradiation,not only does the crater depth increase linearly with the pulse number,but also the quadratic term and constant term of the fitted crater profile curve increase linearly. 展开更多
关键词 laser-material interaction molecular dynamics(MD)simulation ablation crater morphology MAGNESIUM
下载PDF
Transperineal laser ablation of the prostate as a treatment for benign prostatic hyperplasia and prostate cancer: The results of a Delphi consensus project
10
作者 Andrea Cocci Marta Pezzoli +35 位作者 Fernando Bianco Franco Blefari Pierluigi Bove Francois Cornud Gaetano De Rienzo Paolo Destefanis Danilo Di Trapani Alessandro Giacobbe Luca Giovanessi Antonino Laganà Giovanni Lughezzani Guglielmo Manenti Gianluca Muto Gianluigi Patelli Novello Pinzi Stefano Regusci Giorgio I.Russo Juan I.M.Salamanca Matteo Salvi Luigi Silvestri Fabrizio Verweij Eric Walser Riccardo GBertolo Valerio Iacovelli Alessandro Bertaccini Debora Marchiori Hugo Davila Pasquale Ditonno Paolo Gontero Gennaro Iapicca Theo M De Reijke Vito Ricapito Pierluca Pellegrini Andrea Minervini Sergio Serni Francesco Sessa 《Asian Journal of Urology》 CSCD 2024年第2期271-279,共9页
Objective: To evaluate transperineal laser ablation (TPLA) with Echolaser® (Echolaser® TPLA, Elesta S.p.A., Calenzano, Italy) as a treatment for benign prostatic hyperplasia (BPH) and prostate cancer (PCa) u... Objective: To evaluate transperineal laser ablation (TPLA) with Echolaser® (Echolaser® TPLA, Elesta S.p.A., Calenzano, Italy) as a treatment for benign prostatic hyperplasia (BPH) and prostate cancer (PCa) using the Delphi consensus method.Methods: Italian and international experts on BPH and PCa participated in a collaborative consensus project. During two rounds, they expressed their opinions on Echolaser® TPLA for the treatment of BPH and PCa answering online questionnaires on indications, methodology, and potential complications of this technology. Level of agreement or disagreement to reach consensus was set at 75%. If the consensus was not achieved, questions were modified after each round. A final round was performed during an online meeting, in which results were discussed and finalized.Results: Thirty-two out of forty invited experts participated and consensus was reached on all topics. Agreement was achieved on recommending Echolaser® TPLA as a treatment of BPH in patients with ample range of prostate volume, from <40 mL (80%) to >80 mL (80%), comorbidities (100%), antiplatelet or anticoagulant treatment (96%), indwelling catheter (77%), and strong will of preserving ejaculatory function (100%). Majority of respondents agreed that Echolaser® TPLA is a potential option for the treatment of localized PCa (78%) and recommended it for low-risk PCa (90%). During the final round, experts concluded that it can be used for intermediate-risk PCa and it should be proposed as an effective alternative to radical prostatectomy for patients with strong will of avoiding urinary incontinence and sexual dysfunction. Almost all participants agreed that the transperineal approach of this organ-sparing technique is safer than transrectal and transurethral approaches typical of other techniques (97% of agreement among experts). Pre-procedural assessment, technical aspects, post-procedural catheterization, pharmacological therapy, and expected outcomes were discussed, leading to statements and recommendations.Conclusion: Echolaser® TPLA is a safe and effective procedure that treats BPH and localized PCa with satisfactory functional and sexual outcomes. 展开更多
关键词 Transperineal laser ablation Prostatecancer Benignprostatic hyperplasia Delphi consensus
下载PDF
Severe hypoxemia after radiofrequency ablation for atrial fibrillation in palliatively repaired tetralogy of Fallot: A case report
11
作者 Zhi-Hang Li Lian Lou +3 位作者 Yu-Xiao Chen Wen Shi Xuan Zhang Jian Yang 《World Journal of Cardiology》 2024年第3期161-167,共7页
BACKGROUND Patients with tetralogy of Fallot(TOF)often have arrhythmias,commonly being atrial fibrillation(AF).Radiofrequency ablation is an effective treatment for AF and does not usually cause severe postoperative h... BACKGROUND Patients with tetralogy of Fallot(TOF)often have arrhythmias,commonly being atrial fibrillation(AF).Radiofrequency ablation is an effective treatment for AF and does not usually cause severe postoperative hypoxemia,but the risk of complications may increase in patients with conditions such as TOF.CASE SUMMARY We report a young male patient with a history of TOF repair who developed severe hypoxemia after radiofrequency ablation for AF and was ultimately confirmed to have a new right-to-left shunt.The patient subsequently underwent atrial septal occlusion and eventually recovered.CONCLUSION Radiofrequency ablation may cause iatrogenic atrial septal injury;thus possible complications should be predicted in order to ensure successful treatment and patient safety. 展开更多
关键词 Atrial fibrillation Radiofrequency ablation Tetralogy of Fallot Right-to-left shunt HYPOXEMIA Medical decision Case report
下载PDF
Short-term efficacy of microwave ablation in the treatment of liver cancer and its effect on immune function
12
作者 Li-Jun Yao Xiao-Ding Zhu +5 位作者 Liu-Min Zhou Li-Li Zhang Na-Na Liu Min Chen Jia-Ying Wang Shao-Jun Hu 《World Journal of Clinical Cases》 SCIE 2024年第18期3395-3402,共8页
BACKGROUND Hepatectomy is the first choice for treating liver cancer.However,inflammatory factors,released in response to pain stimulation,may suppress perioperative immune function and affect the prognosis of patient... BACKGROUND Hepatectomy is the first choice for treating liver cancer.However,inflammatory factors,released in response to pain stimulation,may suppress perioperative immune function and affect the prognosis of patients undergoing hepatectomies.AIM To determine the short-term efficacy of microwave ablation in the treatment of liver cancer and its effect on immune function.METHODS Clinical data from patients with liver cancer admitted to Suzhou Ninth People’s Hospital from January 2020 to December 2023 were retrospectively analyzed.Thirty-five patients underwent laparoscopic hepatectomy for liver cancer(liver cancer resection group)and 35 patients underwent medical image-guided microwave ablation(liver cancer ablation group).The short-term efficacy,complications,liver function,and immune function indices before and after treatment were compared between the two groups.RESULTS One month after treatment,19 patients experienced complete remission(CR),8 patients experienced partial remission(PR),6 patients experienced stable disease(SD),and 2 patients experienced disease progression(PD)in the liver cancer resection group.In the liver cancer ablation group,21 patients experienced CR,9 patients experienced PR,3 patients experienced SD,and 2 patients experienced PD.No significant differences in efficacy and complications were detected between the liver cancer ablation and liver cancer resection groups(P>0.05).After treatment,total bilirubin(41.24±7.35 vs 49.18±8.64μmol/L,P<0.001),alanine aminotransferase(30.85±6.23 vs 42.32±7.56 U/L,P<0.001),CD4+(43.95±5.72 vs 35.27±5.56,P<0.001),CD8+(20.38±3.91 vs 22.75±4.62,P<0.001),and CD4+/CD8+(2.16±0.39 vs 1.55±0.32,P<0.001)were significantly different between the liver cancer ablation and liver cancer resection groups.CONCLUSION The short-term efficacy and safety of microwave ablation and laparoscopic surgery for the treatment of liver cancer are similar,but liver function recovers quickly after microwave ablation,and microwave ablation may enhance immune function. 展开更多
关键词 Microwave ablation Liver cancer Short-term efficacy Liver function Immunologic function
下载PDF
Camrelizumab,apatinib and hepatic artery infusion chemotherapy combined with microwave ablation for advanced hepatocellular carcinoma
13
作者 Meng-Xuan Zuo Chao An +5 位作者 Yu-Zhe Cao Jia-Yu Pan Lu-Ping Xie Xin-Jing Yang Wang Li Pei-Hong Wu 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第8期3481-3495,共15页
BACKGROUND Hepatic arterial infusion chemotherapy and camrelizumab plus apatinib(TRIPLET protocol)is promising for advanced hepatocellular carcinoma(Ad-HCC).However,the usefulness of microwave ablation(MWA)after TRIPL... BACKGROUND Hepatic arterial infusion chemotherapy and camrelizumab plus apatinib(TRIPLET protocol)is promising for advanced hepatocellular carcinoma(Ad-HCC).However,the usefulness of microwave ablation(MWA)after TRIPLET is still controversial.AIM To compare the efficacy and safety of TRIPLET alone(T-A)vs TRIPLET-MWA(TM)for Ad-HCC.METHODS From January 2018 to March 2022,217 Ad-HCC patients were retrospectively enrolled.Among them,122 were included in the T-A group,and 95 were included in the T-M group.A propensity score matching(PSM)was applied to balance bias.Overall survival(OS)was compared using the Kaplan-Meier curve with the log-rank test.The overall objective response rate(ORR)and major complications were also assessed.RESULTS After PSM,82 patients were included both the T-A group and the T-M group.The ORR(85.4%)in the T-M group was significantly higher than that(65.9%)in the T-A group(P<0.001).The cumulative 1-,2-,and 3-year OS rates were 98.7%,93.4%,and 82.0%in the T-M group and 85.1%,63.1%,and 55.0%in the T-A group(hazard ratio=0.22;95%confidence interval:0.10-0.49;P<0.001).The incidence of major complications was 4.9%(6/122)in the T-A group and 5.3%(5/95)in the T-M group,which were not significantly different(P=1.000).CONCLUSION T-M can provide better survival outcomes and comparable safety for Ad-HCC than T-A. 展开更多
关键词 Hepatic arterial infusion chemotherapy Hepatocellular carcinoma Molecular targeting agent Programmed cell death protein 1 inhibitors Microwave ablation
下载PDF
Percutaneous transhepatic cholangiography:An effective option for endo-biliary radiofrequency ablation before stent insertion in unresectable biliary cancer?
14
作者 Dimitrios S Karagiannakis 《World Journal of Clinical Cases》 SCIE 2024年第30期6413-6416,共4页
Biliary cancer is a highly aggressive disease that is typically diagnosed at advanced stages when surgical removal is no longer an option.In these cases,palliative care and mechanical widening of the blocked biliary s... Biliary cancer is a highly aggressive disease that is typically diagnosed at advanced stages when surgical removal is no longer an option.In these cases,palliative care and mechanical widening of the blocked biliary system are preferred.The insertion of a stent is often necessary to prevent the recurrence of blockages caused by cancer progression.Prior to stent placement,endo-biliary radiofrequency ablation(EB-RFA)appears to result in longer-lasting stent effectiveness without increasing the risk of severe complications.However,its impact on overall survival is not yet clear.Additionally,while endoscopic retrograde cholangiopancreatography is the most common method for performing EB-RFA,percutaneous transhepatic cholangiodrainage seems to be a safe and potentially more efficient alternative,particularly for long,angulated,or significantly narrowed bile ducts. 展开更多
关键词 Biliary cancer CHOLANGIOCARCINOMA Pancreatic cancer Percutaneous transhepatic cholangiodrainage Radiofrequency ablation
下载PDF
Role of ablation therapy in conjunction with surgical resection for neuroendocrine tumors involving the liver
15
作者 Alexander Ostapenko Stephanie Stroever +4 位作者 Lud Eyasu Minha Kim Krist Aploks Xiang Da Dong Ramanathan Seshadri 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期768-776,共9页
BACKGROUND Resection of hepatic metastasis from neuroendocrine tumors(NETs)improves quality of life and prolongs 5-year survival.Ablation can be utilized with surgery to achieve complete resection.Although several stu... BACKGROUND Resection of hepatic metastasis from neuroendocrine tumors(NETs)improves quality of life and prolongs 5-year survival.Ablation can be utilized with surgery to achieve complete resection.Although several studies report long-term out-comes for patients undergoing ablation,none have explored perioperative effects of ablation in patients with metastatic NETs.AIM To determine if intra-operative ablation during hepatectomy increases risk of ad-verse outcomes such as surgical site infections(SSIs),bleeding,and bile leak.METHODS A retrospective analysis of the hepatectomy National Surgical Quality Impro-vement Program database from 2015-2019 was performed to determine the odds of SSIs,bile leaks,or bleeding in patients undergoing intraoperative ablation when compared to hepatectomy alone.RESULTS Of the 966 patients included in the study,298(30.9%)underwent ablation during hepatectomy.There were 78(11.7%)patients with SSIs in the hepatectomy alone group and 39(13.1%)patients with a SSIs in the hepatectomy with ablation group.Bile leak occurred in 41(6.2%)and 14(4.8%)patients in the two groups,respec-tively;bleeding occurred in 117(17.5%)and 33(11.1%),respectively.After con-trolling for confounding variables,ablation did not increase risk of SSI(P=0.63),bile leak(P=0.34)or bleeding(P=0.07)when compared to patients undergoing resection alone on multivariate analysis.CONCLUSION Intraoperative ablation with hepatic resection for NETs is safe in the perioperative period without significant increased risk of infection,bleeding,or bile leak.Surgeons should utilize this modality when appropriate to a-chieve optimal disease control and outcomes. 展开更多
关键词 HEPATECTOMY Neuroendocrine tumor ablation Bile leaks BLEEDING Surgical site infections
下载PDF
Paravertebral block's effect on analgesia and inflammation in advanced gastric cancer patients undergoing transarterial chemoembolization and microwave ablation
16
作者 Ying-Fen Xiong Ben-Zhong Wei +2 位作者 Yu-Feng Wang Xiao-Feng Li Cong Liu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期196-204,共9页
BACKGROUND Transarterial chemoembolization(TACE)combined with microwave ablation(MWA)is an effective treatment strategy for patients with advanced gastric cancer and liver metastasis.However,it may cause severe postop... BACKGROUND Transarterial chemoembolization(TACE)combined with microwave ablation(MWA)is an effective treatment strategy for patients with advanced gastric cancer and liver metastasis.However,it may cause severe postoperative pain and inflammatory responses.The paravertebral block(PVB)is a regional anesthetic technique that provides analgesia to the thoracic and abdominal regions.AIM To evaluate the effect of PVB on postoperative analgesia and inflammatory response in patients undergoing TACE combined with MWA for advanced gastric cancer and liver metastasis.METHODS Sixty patients were randomly divided into PVB and control groups.The PVB group received ultrasound-guided PVB with 0.375%ropivacaine preoperatively,whereas the control group received intravenous analgesia with sufentanil.The primary outcome was the visual analog scale(VAS)score for pain at 6 h,12 h,24 h,and 48 h after the procedure.Secondary outcomes were the dose of sufentanil used,incidence of adverse events,and levels of inflammatory markers(white blood cell count,neutrophil percentage,C-reactive protein,and procalcitonin)before and after the procedure.RESULTS The PVB group had significantly lower VAS scores at 6 h,12 h,24 h,and 48 h after the procedure compared with the control group(P<0.05).The PVB group also had a significantly lower consumption of sufentanil and a lower incidence of nausea,vomiting,and respiratory depression than did the control group(P<0.05).Compared with the control group,the PVB group had significantly lower levels of inflammatory markers 24 h and 48 h after the procedure(P<0.05).CONCLUSION PVB can effectively reduce postoperative pain and inflammatory responses and improve postoperative comfort and recovery in patients with advanced gastric cancer and liver metastasis treated with TACE combined with MWA. 展开更多
关键词 Transarterial chemoembolization Microwave ablation Paravertebral block Visual analog scale SUFENTANIL Inflammatory markers
下载PDF
Analysis of alkaline phosphatase and γ-glutamyltransferase after radiofrequency ablation of primary liver cancer: A retrospective study
17
作者 Wen-Yu Huang Sheng Zheng +7 位作者 Dan Zhu Ying-Lang Zeng Juan Yang Xue-Li Zeng Pei Liu Shun-Ling Zhang Ming Yuan Zhi-Xia Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第9期2860-2869,共10页
BACKGROUND Changes in alkaline phosphatase(ALP)andγ-glutamyltransferase(GGT)levels in patients with primary liver cancer(PLC)after radiofrequency ablation(RFA).Hepatocellular carcinoma is a malignant tumor with high ... BACKGROUND Changes in alkaline phosphatase(ALP)andγ-glutamyltransferase(GGT)levels in patients with primary liver cancer(PLC)after radiofrequency ablation(RFA).Hepatocellular carcinoma is a malignant tumor with high incidence worldwide.As a common local treatment,RFA has attracted much attention for its efficacy and influence on liver function.AIM To investigate the effect of serum ALP and GGT levels on the prognosis of patients with PLC treated by RFA.METHODS The preoperative clinical data of 165 patients who were pathologically or clinically diagnosed with PLC and who received RFA in our hospital between October 2018 and June 2023 were collected.The chi-square test was used to compare the data between groups.The Kaplan-Meier method and Cox regression were used to analyze the associ-ations between serum ALP and GGT levels and overall survival,progression-free survival(PFS)and clinical characteristics of patients before treatment.RESULTS The 1-year survival rates of patients with normal(≤135 U/L)and abnormal(>135 U/L)serum ALP before treatment were 91%and 79%,respectively;the 2-year survival rates were 90%and 68%,respectively;and the 5-year survival rates were 35%and 18%,respectively.The difference between the two groups was statistically significant(P=0.01).Before treatment,the 1-year survival rates of patients with normal serum GGT levels(≤45 U/L)and abnormal serum GGT levels(>45 U/L)were 95%and 87%,the 2-year survival rates were 85%and 71%,and the 5-year survival rates were 37%and 21%,respectively.The difference between the two groups was statist-ically significant(P<0.001).Serum ALP[hazard ratio(HR)=1.766,95%confidence interval(95%CI):1.068-2.921,P=0.027]and GGT(HR=2.312,95%CI:1.367-3.912,P=0.002)is closely related to the overall survival of PLC patients after RF ablation and is an independent prognostic factor.The 1-year PFS rates were 72%and 50%,the 2-year PFS rates were 52%and 21%,and the 5-year PFS rates were 14%and 3%,respectively.The difference between the two groups was statistically significant(P<0001).The 1-year PFS rates were 81%and 56%in patients with normal and abnormal serum GGT levels before treatment,respectively;the 2-year PFS rates were 62%and 35%,respectively;and the 5-year PFS rates were 18%and 7%,respectively,with statistical significance between the two groups(P<0.001).The serum ALP concentration(HR=1.653,95%CI:1.001-2.729,P=0.049)and GGT(HR=1.949,95%CI:1.296-2.930,P=0.001)was closely associated with PFS after RFA in patients with PLC.The proportion of male patients with abnormal ALP levels is high,the Child-Pugh grade of liver function is poor,and the incidence of ascites is high.Among GGT-abnormal patients,the Child-Pugh grade of liver function was poor,the tumor stage was late,the proportion of patients with tumors≥5 cm was high,and the incidence of hepatic encephalopathy was high.CONCLUSION Serum ALP and GGT levels before treatment can be used to predict the prognosis of patients with PLC after RFA,and they have certain guiding significance for the long-term survival of patients with PLC after radiofrequency therapy. 展开更多
关键词 Alkaline phosphatase γ-glutamyltransferase Radiofrequency ablation Primary liver cancer Retrospective study
下载PDF
Efficacy and safety of B-ultrasound-guided radiofrequency ablation in the treatment of primary liver cancer: Systematic review and metaanalysis
18
作者 Xiong Zhang Hong-Yi Zhu Ming Yuan 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第9期2986-2995,共10页
BACKGROUND Primary liver cancer is one of the most lethal malignancies in the world.Tradi-tional treatment methods have limitations in terms of efficacy and safety.Ra-diofrequency ablation(RFA)guided by B-ultrasound,a... BACKGROUND Primary liver cancer is one of the most lethal malignancies in the world.Tradi-tional treatment methods have limitations in terms of efficacy and safety.Ra-diofrequency ablation(RFA)guided by B-ultrasound,as a minimally invasive treatment,has attracted increasing attention in the treatment of primary liver cancer in recent years.AIM To study the efficacy and safety of RFA were compared with those of traditional surgery(TS)for treating small liver cancer.METHODS At least 2 people were required to search domestic and foreign public databases,including foreign databases such as EMBASE,PubMed and the Cochrane Library,and Chinese databases such as the China National Knowledge Infrastructure database,China Biomedical Literature database,Wanfang database and VIP database.Controlled trials of RFA vs conventional surgery for small liver cancer were retrieved from January 2008 to January 2023.They were screened and eva-luated according to the quality evaluation criteria in the Cochrane Handbook of Systematic Reviews.The meta-analysis was performed using RevMan 5.3 soft-ware.RESULTS A total of 10 studies were included in this study,including 1503 patients in the RFA group and 1657 patients in the surgery group.The results of the meta-ana-lysis showed that there was no significant difference in 1-year overall survival between the two groups(P>0.05),while the 3-year and 5-year overall survival rates and 1-year,3-year and 5-year tumor-free survival rates in the surgery group were greater than those in the RFA group(P<0.05).In terms of complications,the incidence of complications in the RFA group was lower than that in the surgery group(P<0.05).CONCLUSION In terms of long-term survival,TS is better than RFA for small liver cancer patients.However,RFA has fewer complications and is safer. 展开更多
关键词 Survival prognosis Small liver cancer Radiofrequency ablation Traditional surgical resection META-ANALYSIS
下载PDF
Radiofrequency ablation combined with transcatheter arterial chemoembolization for recurrent liver cancer
19
作者 Jin-You Guo Li-Li Zhao +2 位作者 Hui-Jun Cai Hui Zeng Wei-Dong Mei 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1756-1764,共9页
BACKGROUND The recurrence rate of liver cancer after surgery is high.Radiofrequency ablation(RFA)combined with transcatheter arterial chemoembolization(TACE)is an effective treatment for liver cancer;however,its effic... BACKGROUND The recurrence rate of liver cancer after surgery is high.Radiofrequency ablation(RFA)combined with transcatheter arterial chemoembolization(TACE)is an effective treatment for liver cancer;however,its efficacy in recurrent liver cancer remains unclear.AIM To investigate the clinical effect of TACE combined with RFA in the treatment of recurrent liver cancer.METHODS Ninety patients with recurrent liver cancer were divided into 2 groups according to treatment plan:Control(RFA alone);and experimental[TACE combined with RFA(TACE+RFA)].The incidence of increased alanine aminotransferase levels,complications,and other indices were compared between the two groups before and after the procedures.RESULTS One month after the procedures,the short-term efficacy rate and Karnofsky Performance Status scores of the experimental group were significantly higher than those of the control group(P<0.05).Alpha-fetoprotein(AFP)and total bilirubin levels were lower than those in the control group(P<0.05);The overall response rate was 82.22%and 66.67%in the experimental and control groups,respectively;The disease control rate was 93.33%and 82.22%in the experimental and control groups,respectively,the differences are statistically significant(P<0.05).And there were no statistical differences in complications between the two groups(P>0.05).CONCLUSION TACE+RFA was effective for the treatment of recurrent liver cancer and significantly reduced AFP levels and improved various indices of liver function. 展开更多
关键词 Transcatheter arterial chemoembolization Radiofrequency ablation Recurrent liver cancer Clinical efficacy Overall response rate Disease control rate
下载PDF
High performance micromachining of sapphire by laser induced plasma assisted ablation(LIPAA)using GHz burst mode femtosecond pulses
20
作者 Kotaro Obata Shota Kawabata +2 位作者 Yasutaka Hanada Godai Miyaji Koji Sugioka 《Opto-Electronic Science》 2024年第6期20-29,共10页
GHz burst-mode femtosecond(fs)laser,which emits a series of pulse trains with extremely short intervals of several hundred picoseconds,provides distinct characteristics in materials processing as compared with the con... GHz burst-mode femtosecond(fs)laser,which emits a series of pulse trains with extremely short intervals of several hundred picoseconds,provides distinct characteristics in materials processing as compared with the conventional irradiation scheme of fs laser(single-pulse mode).In this paper,we take advantage of the moderate pulse interval of 205 ps(4.88 GHz)in the burst pulse for high-quality and high-efficiency micromachining of single crystalline sapphire by laser induced plasma assisted ablation(LIPAA).Specifically,the preceding pulses in the burst generate plasma by ablation of copper placed behind the sapphire substrate,which interacts with the subsequent pulses to induce ablation at the rear surface of sapphire substrates.As a result,not only the ablation quality but also the ablation efficiency and the fabrication resolution are greatly improved compared to the other schemes including single-pulse mode fs laser direct ablation,single-pulse mode fs-LIPAA,and nanosecond-LIPAA. 展开更多
关键词 femtosecond laser GHz burst mode ablation LIPAA laser induced plasma assisted ablation SAPPHIRE
下载PDF
上一页 1 2 66 下一页 到第
使用帮助 返回顶部