期刊文献+
共找到6,455篇文章
< 1 2 250 >
每页显示 20 50 100
Transfer film effects induced by 3D-printed polyether-ether-ketone with excellent tribological properties for joint prosthesis
1
作者 Yang Li Jibao Zheng +1 位作者 Changning Sun Dichen Li 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期43-56,共14页
Based on the building principle of additive manufacturing,printing orientation mainly determines the tribological properties of joint prostheses.In this study,we created a polyether-ether-ketone(PEEK)joint prosthesis ... Based on the building principle of additive manufacturing,printing orientation mainly determines the tribological properties of joint prostheses.In this study,we created a polyether-ether-ketone(PEEK)joint prosthesis using fused filament fabrication and investigated the effects of printing orientation on its tribological properties using a pin-on-plate tribometer in 25% newborn calf serum.An ultrahigh molecular weight polyethylene transfer film is formed on the surface of PEEK due to the mechanical capture of wear debris by the 3D-printed groove morphology,which is significantly impacted by the printing orientation of PEEK.When the printing orientation was parallel to the sliding direction of friction,the number and size of the transfer film increased due to higher steady stress.This transfer film protected the matrix and reduced the friction coefficient and wear rate of friction pairs by 39.13%and 74.33%,respectively.Furthermore,our findings provide a novel perspective regarding the role of printing orientation in designing knee prostheses,facilitating its practical applications. 展开更多
关键词 3D printing orientation Transfer film Tribological properties Polyether-ether-ketone Knee prosthesis
下载PDF
Indication and surgical approach for reconstruction with endoprosthesis in bone-associated soft tissue sarcomas:Appropriate case management is vital
2
作者 RecepÖztürk 《World Journal of Clinical Cases》 SCIE 2024年第12期2004-2008,共5页
It is important for surgeons performing sarcoma surgery to know that bone resection and tumor prosthesis applications in soft tissue sarcomas(STS)have unique features in terms of indication,surgical approach and follo... It is important for surgeons performing sarcoma surgery to know that bone resection and tumor prosthesis applications in soft tissue sarcomas(STS)have unique features in terms of indication,surgical approach and follow-up,in terms of the management of these cases.Some STS are associated with bone and major neurovascular structures.Bone-associated STS are generally relatively large and relatively deep-seated.Additionally,the tendency for metastasis is high.In some cases,the decision about which structures to resect is difficult.These cases are often accompanied by poor oncological and surgical outcomes.Management of cases should be done by a multidisciplinary team in advanced centers specialized in this field.The surgical team must have sufficient knowledge and experience in the field of limb-sparing surgery.Preoperative evaluation and especially good planning of bone and soft tissue reconstruction are vital. 展开更多
关键词 Soft tissue sarcoma Bone invasion Bone resection Endoprosthesis replacement prosthesis Limb salvage INDICATION Approach
下载PDF
Gait Analysis of a Subject with Tarsometatarsal Prosthesis
3
作者 Carlos Diaz Novo Walter Mar Haller +3 位作者 Emiliano Alvarez Ruiz Micaela González Castillo Manuel Bárbaro Cuadra Mateo Olivera García 《Journal of Biosciences and Medicines》 2023年第10期284-297,共14页
Introduction: Gait analysis of an adult man after trans-metatarsal unilateral amputation is described. Objective: Instrumental gait analysis of a subject 15 years after trans-metatarsal unilateral amputation in two fo... Introduction: Gait analysis of an adult man after trans-metatarsal unilateral amputation is described. Objective: Instrumental gait analysis of a subject 15 years after trans-metatarsal unilateral amputation in two footwear conditions: while walking barefoot and with prosthesis. Materials and Methods: In a movement analysis laboratory, locomotion studies were carried out at freely chosen walking speed by a 65-year-old subject, obtaining kinematic, kinetic and surface electromyographic data in time and space. Gait analysis was performed using instrumental technologies from a digital eco-system applying walking protocols. Results: When the patient wore the prosthesis, several positive improvements were observed in various aspects of gait. These included enhancements in the base of support, gait speed, and joint range of movements. Additionally, there was a slight improvement in the vertical ground reaction forces pattern, indicating a positive effect of the assistive technology. Furthermore, the use of the prosthesis led to a more organized pattern of muscle activity, which further supports its beneficial impact. However, it is worth noting that some challenges still persisted, particularly regarding stabilizing the body during the double support phase. Despite this difficulty, the overall findings suggest that the use of the prosthesis offers valuable improvements to the patient’s gait dynamics. Conclusions: After conducting a thorough analysis of the parameters related to the gait of a subject who underwent a trans-metatarsal unilateral amputation fifteen years ago, it was found that the use of prosthesis had a positive impact. This study demonstrated important improvements in some kinematic and kinetic parameters, including muscle activation patterns, indicating an increase in comfort and confidence while utilizing the prosthetic device. 展开更多
关键词 Tarsometatarsal Amputation prosthesis GAIT Motion Analysis Laboratory
下载PDF
Electrophysiological evaluation of alterations in penile sensation due to penile prosthesis implantation in patients with erectile dysfunction
4
作者 İbrahim Erol Ali Yıldız +5 位作者 Kaan Karamık Hakan Anıl Ekremİslamoğlu TuncayÇakır Mutlu Ateş Murat Savaş 《Asian Journal of Urology》 CSCD 2023年第4期541-545,共5页
Objective The present study was aimed to determine the effect of penile prosthesis implantation(PPI)surgery on penile sensation by evaluating the penile electromyography(EMG)variables.Methods The research was designed... Objective The present study was aimed to determine the effect of penile prosthesis implantation(PPI)surgery on penile sensation by evaluating the penile electromyography(EMG)variables.Methods The research was designed as a prospective study.Thirty patients who were diagnosed with organic erectile dysfunction and had underwent PPI surgery between January 2017 and January 2018 in the Urology Clinic of Antalya Training and Research Hospital were included in this study.Penile sensory EMG was performed on each patient 1 day prior to the surgery by the Physical Therapy and Rehabilitation clinic.Additionally,the control EMG study was also performed in the 3rd and 6th postoperative months.Results We included 27 patients in this study who attended regular follow-ups and had complete EMG results.Out of the 27 patients,23(85.2%)patients had received malleable(ProMedon)penile prosthesis,one(3.7%)patient had received a two-piece inflatable(Ambicor)penile prosthesis,and three(11.1%)patients had received a three-piece inflatable(AMS 700 CXR)penile prosthesis.The mean nerve conduction value(NCV)of the patients was 29.85(standard derivation:22.54;range:0-78.4)m/s during the preoperative period,whereas it was 27.64(standard derivation:24.72;range:0-83.3)m/s in the 3rd postoperative month and 24.80(standard derivation:22.31;range:0-88.4)m/s in the 6th postoperative month.There was no significant difference between preoperative NCV and 3rd postoperative month NCV(p=0.607).Similarly,no significant difference was observed between preoperative NCV and 6th postoperative month NCV(p=0.276).Additionally,the change between NCV values at postoperative 3rd and 6th months was not statistically significant(p=0.553).Conclusion Significant loss of penile sensation does not occur in patients who undergo PPI surgery. 展开更多
关键词 Penile prosthesis Penile sensation ELECTROMYOGRAPHY Erectile dysfunction
下载PDF
A new passive transfemoral prosthesis mechanism based on 3R36 knee and ESAR foot providing walking and squatting
5
作者 Amer Imran Borhan Beigzadeh Mohammad Reza Haghjoo 《Theoretical & Applied Mechanics Letters》 CSCD 2023年第5期399-407,共9页
Researchers have proposed various linkage mechanisms to connect knee and ankle joints for above-knee prosthe-ses,but most of them only offer natural walking.However,studies have shown that people assume a squatting po... Researchers have proposed various linkage mechanisms to connect knee and ankle joints for above-knee prosthe-ses,but most of them only offer natural walking.However,studies have shown that people assume a squatting posture during daily activities.This paper introduces a novel mechanism that connects the knee joint with the foot-ankle joint to enable both squatting and walking.The prosthetic knee used is the well-known 3R36,while the energy storing and return(ESAR)prosthetic foot is used for the ankle-foot joint.To coordinate knee and ankle joint movements,a six-bar linkage mechanism structure is proposed.Simulation results demonstrate that the proposed modular transfemoral prosthesis accurately mimics the motion patterns of a natural human leg during walking and squatting.For instance,the prosthesis allows a total knee flexion of more than 140°during squatting.The new prosthesis design also incorporates energy-storing mechanisms to reduce energy expenditure during walking for amputees. 展开更多
关键词 Transfemoral leg amputation Passive prosthesis SQUATTING WALKING Six-bar mechanism Energy saving
下载PDF
Current situation and development of facial prosthesis
6
作者 Xin Li Jia Xu +4 位作者 Jiajun Fan Yaxin Xue Xiaoding Gu Hengxing Zhou Dong Han 《Chinese Journal Of Plastic and Reconstructive Surgery》 2023年第1期39-42,共4页
Facial prostheses have developed significantly in the last 10 years,especially between 2016 and 2021.This development is mainly due to the great progress made in the fields of biocompatible materials,digital technolog... Facial prostheses have developed significantly in the last 10 years,especially between 2016 and 2021.This development is mainly due to the great progress made in the fields of biocompatible materials,digital technology,and three-dimensional printing technology,which provides guarantee for low allergy,high biosimulation,comfort,and satisfactory usability.Treatment teams typically consist of plastic surgeons,material experts,engineers,and computer scientists who have extensive clinical experience.These teams successfully implement an integrated,multidisciplinary model by prioritizing the reasonable expectations of both the physician and patient,leading to improved patient satisfaction and compliance with prosthetic constraints.This study aimed to review the concept,development status,existing problems,and future of facial prosthesis. 展开更多
关键词 prosthesis MATERIAL Facial defects Digital process
下载PDF
Development and clinical application of a new testicular prosthesis 被引量:4
7
作者 Ye Ning Zhikang Cai +4 位作者 Huixing Chen Ping Ping Peng Li Zhong Wang Zheng Li 《Asian Journal of Andrology》 SCIE CAS CSCD 2011年第6期903-904,共2页
A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to ... A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction. 展开更多
关键词 ORCHIECTOMY silastic prosthesis testicular prosthesis
下载PDF
Treatment of acute periprosthetic infections with prosthesis retention: Review of current concepts 被引量:12
8
作者 Jesse WP Kuiper Robin Tjeenk Willink +2 位作者 Dirk Jan F Moojen Michel PJ van den Bekerom Sascha Colen 《World Journal of Orthopedics》 2014年第5期667-676,共10页
Periprosthetic joint infection(PJI) is a devastating complication after total joint arthroplasty, occurring in approximately 1%-2% of all cases. With growing populations and increasing age, PJI will have a growing eff... Periprosthetic joint infection(PJI) is a devastating complication after total joint arthroplasty, occurring in approximately 1%-2% of all cases. With growing populations and increasing age, PJI will have a growing effect on health care costs. Many risk factors have been identified that increase the risk of developing PJI, including obesity, immune system deficiencies, malignancy, previous surgery of the same joint and longer operating time. Acute PJI occurs either postoperatively(4 wk to 3 mo after initial arthroplasty, depending on the classification system), or via hematogenous spreading after a period in which the prosthesis had functioned properly. Diagnosis and the choice of treatment are the cornerstones to success. Although different definitions for PJI have been used in the past, most are more or less similar and include the presence of a sinus tract, blood infection values, synovial white blood cell count, signs of infection on histopathological analysis and one ormore positive culture results. Debridement, antibiotics and implant retention(DAIR) is the primary treatment for acute PJI, and should be performed as soon as possible after the development of symptoms. Success rates differ, but most studies report success rates of around 60%-80%. Whether single or multiple debridement procedures are more successful remains unclear. The use of local antibiotics in addition to the administration of systemic antibiotic agents is also subject to debate, and its pro's and con's should be carefully considered. Systemic treatment, based on culture results, is of importance for all PJI treatments. Additionally, rifampin should be given in Staphylococcal PJIs, unless all foreign material is removed. The most important factors contributing to treatment failure are longer duration of symptoms, a longer time after initial arthroplasty, the need for more debridement procedures, the retention of exchangeable components, and PJI caused by Staphylococcus(aureus or coagulase negative). If DAIR treatment is unsuccessful, the following treatment option should be based on the patient health status and his or her expectations. For the best functional outcome, one- or two-stage revision should be performed after DAIR failure. In conclusion, DAIR is the obvious choice for treatment of acute PJI, with good success rates in selected patients. 展开更多
关键词 Arthroplasty prosthesis INFECTION PERIPROSTHETIC joint INFECTION RETENTION DEBRIDEMENT antibiotics and implant RETENTION DEBRIDEMENT ACUTE
下载PDF
Prospective and long-term evaluation of erect penile length obtained with inflatable penile prosthesis to that induced by intracavernosal injection 被引量:3
9
作者 Run Wang Galen E Howard +3 位作者 Anthony Hoang Jiu-Hong Yuan Hao-Cheng Lin Yu-Tian Dai 《Asian Journal of Andrology》 SCIE CAS CSCD 2009年第4期411-416,共6页
We compared erect penile length after inflatable penile prosthesis (IPP) implantation with that induced by intracavemosal injection (ICI) before surgery. A total of 11 patients with full erections induced by ICI o... We compared erect penile length after inflatable penile prosthesis (IPP) implantation with that induced by intracavemosal injection (ICI) before surgery. A total of 11 patients with full erections induced by ICI of 0.25 mL of Trimix (papaverine, phentolamine and prostaglandin E 1) at the time of penile color duplex Doppler ultrasonograpby were enrolled in this study. The patients subsequently underwent IPP implantation as the ultimate treatment for their erectile dysfunction (ED). Erect penile length consequent to IPP implantation was measured at 6 weeks, 6 months and at I year after surgery. The Sexual Health Inventory for Men (SHIM) was administered before, and at 6 months and 1 year after IPP implantation. Erect penile length (mean ± s.c.) as induced by ICI was 13.2 ± 0.4 cm, whereas the lengths attained with IPP were 12.4 ± 0.3, 12.5 ± 0.3 and 12.5 ± 0.4 cm at the sixth week, sixth month and 1-year follow-ups, respectively. There were 0.83 ± 0.25, 0.75 ± 0.20 and 0.74 ± 0.15 cm decreases in erect penile length at 6 weeks, 6 months and 1 year, respectively, after IPP implantation when compared with that after ICI (P 〈 0.05). The SHIM scores for patients reporting shorter penises were the same as those for patients without complaints at the 6-month and 1-year follow-ups (P 〉 0.05). To our knowledge, this is the first study to objectively show a significant decrease in erect penile length after IPP implantation when compared with that after ICI. However, this decrease did not affect the effectiveness of IPP in treating ED. 展开更多
关键词 erectile dysfunction intracavemosal injection LENGTH penile prosthesis radical prostatectomy
下载PDF
Penile prosthesis implantation and tunica albuginea incision without grafting in the treatment of Peyronie's disease with erectile dysfunction 被引量:3
10
作者 Miroslav L Djordjevic Vladimir Kojovic 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第3期391-394,共4页
We evaluated penile prosthesis implantation with tunica albuginea-relaxing incisions without grafting in the treatment of Peyronie's disease associated with erectile dysfunction. Between April 2005 and June 2011, 62 ... We evaluated penile prosthesis implantation with tunica albuginea-relaxing incisions without grafting in the treatment of Peyronie's disease associated with erectile dysfunction. Between April 2005 and June 2011, 62 patients underwent surgery due to severe Peyronie's disease associated with erectile dysfunction. Malleable and inflatable penile prostheses were inserted in 49 and 13 cases, respectively. Penile prostheses were inserted into the corpora cavernosa using the standard ventral approach. After lifting the neurovascular bundle, the tunica albuginea was incised and opened at the plaque region to correct the deformities and to lengthen the penis. Subsequently, the wide neurovascular bundle was replaced, and all incisions of the tunica albuginea were covered to prevent corporal grafting. In the median follow-up of 35 months (range 14-82 months), the penis was completely straightened in 59 (95%) patients. Numbness of the glans, which the patients found initially upsetting, decreased or disappeared spontaneously 3-6 months later. Penile prosthesis implantation with tunica albuginea incisions is a viable alternative in the treatment of Peyronie's disease because the extensive dissection of the neurovascular bundle allows a good approach to the plaque and provides excellent covering of the incised tunica albuginea without additional grafting. 展开更多
关键词 erectile dysfunction neurovascular bundle penile prosthesis Peyronie's disease tunica albuginea
下载PDF
Infection associated with hydroxyapatite prosthesis and related factors 被引量:3
11
作者 LIU Yang SUN Jian-jun Center of Otolaryngology of PLA, Navy General Hospital, Beijing 100037, China 《Journal of Otology》 2010年第1期24-29,共6页
Background The purpose of otomicrosurgery in modern times is to achieve complete removal of disease, which is the basis for hearing rehabilitation. Artificial ossicles are important for hearing rehabilitation. One of ... Background The purpose of otomicrosurgery in modern times is to achieve complete removal of disease, which is the basis for hearing rehabilitation. Artificial ossicles are important for hearing rehabilitation. One of the materials is hydroxyapatite that acts as ossicular replacement prosthesis (HA prosthesis, PORP & TORP) and is commonly used as substitute bone in clinics. Although HA prostheses feature good biocompatibility, stability and certain resistance to infection, the structure of the material can be decomposed and absorbed. Based upon animal experiments and clinical application, this article explores the infectivity of HA prostheses and influencing factors. Materials and Methods HA prostheses were implanted in the bulla in guinea pigs. Infected HA prostheses were examined under a scanning electron microscope. Ninety patients implanted with HA prostheses were followed for more than 3 months. Five cases that had undergone revision operations were reported. Results Scanning electronic microscopy showed that the normal compact structures had disappeared and become loose in infected HA prostheses, with their micropores infiltrated with effusion, fibrous tissue and inflammatory cells. As a result, the normal ceramic structure was decomposed and the micropores structure disappeared. The infected mesotympanum in the reported cases also led to HA infection. The shape and structure of bone were destroyed, which was visible by visual examination and light microscopy. The process of cholesteatoma recurrence was always associated with infection, although the HA prosthesis was sometimes spared. Conclusion While HA prosthesis is anti-infective to some extent, long-term infection and cholesteatoma recurrence can lead to destruction and decomposition of HA prostheses. Long-term infected middle ear cavity, dysfunctional Eustachian tube, residual and recurrent cholesteatoma and other factors can cause decomposition of HA prosthesis and result in hearing loss. 展开更多
关键词 Hydroxyapatite prosthesis INFECTION Cholesteatoma.
下载PDF
Penile prosthesis implantation in Chinese patients wit severe erectile dysfunction: 10-year experience 被引量:3
12
作者 Wei-Dong Song Yi-Ming Yuan +11 位作者 Wan-Shou Cui Alex K Wu Yi-Chen Zhu Jing Liu Lin Wang Guang-Yi Ba Jing Peng Zhi-Chao Zhang Bing Gao Ying-Lu Guo Tom F Lue Zhong-Cheng Xin 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第5期658-661,共4页
We retrospectively evaluated the clinical outcome of penile prosthesis implantation (PPI) in Chinese patients with severe erectile dysfunction (SED). From July 2000 to December 2011, 224 patients (mean age: 35.9... We retrospectively evaluated the clinical outcome of penile prosthesis implantation (PPI) in Chinese patients with severe erectile dysfunction (SED). From July 2000 to December 2011, 224 patients (mean age: 35.9±11.8 years, range: 20-75 years) with SED underwent PPI by experienced surgeon according to standard PPI procedure at our centre. A malleable prosthesis (AMS 650) was implanted in 45 cases (20.1%), and a three-piece inflatable prosthesis (AMS 700 CXM or AMS 700 CXR) was implanted in 179 cases (79.9%). Surgical outcomes, including postoperative complications, clinical efficacy and couple satisfaction, were evaluated over than 6 months postoperatively using medical record abstraction, IIEF-5, quality of life (QoL) scores, and the patient/partner sexual satisfaction score proposed by Bhojwani etaL Of the 224 patients eligible for the study, 201 subjects (89.7%) completed follow-up. All of patients could perform sexual intercourse post PPI with the mean postoperative IIEF-5 and QoL scores were 20.02±2.32 and 5.28±0.76, respectively, which were significantly improved compared with the preoperative scores (6.29±1.5 and 2.13±0.84, P〈0.01). Of the 201 men, mechanical malfunction occurred in four cases (2.0%) and three cases were re-implanted new device, and two cases (1.0%) developed a mild curvature of the penis. Scrotal erosion with infection occurred in one case with diabetes mellitus (0.5%) and required complete removal of the implanted AMS 700 CXM. Satisfactory sexual intercourse at least twice per month was reported by 178 men (88.6%), and overall satisfaction with the PPI surgery was reported by 89.0% of men and 82.5% of partners. Patient satisfaction in the three-piece inflatable prosthesis group was higher than in the malleable prosthesis group (P〈0.05). Satisfaction, however, between the types of prostheses, did not differ in the partner survey. PPI is a safe and effective treatment option for Chinese patients with SED and experienced surgeon perform PPI according to standard PPI procedure could reduce the postoperative complications of PPI and could improve patient satisfaction ratio and QoL. 展开更多
关键词 COMPLICATION erectile dysfunction (ED) IMPLANTATION quality of life (QoL) penile prosthesis SATISFACTION
下载PDF
Can periprosthetic hip joint infections be successfully managed by debridement and prosthesis retention? 被引量:3
13
作者 Konstantinos Anagnostakos Cornelia Schmitt 《World Journal of Orthopedics》 2014年第3期218-224,共7页
To evaluate the current literature about how successfully periprosthetic hip joint infections can be managed by debridement and prosthesis retention.A literature search was performed through Pub Med until September 20... To evaluate the current literature about how successfully periprosthetic hip joint infections can be managed by debridement and prosthesis retention.A literature search was performed through Pub Med until September 2013.Search terms were"DAIR(debridement,antibiotics,irrigation,and retention)"alone and in combination with"hip"as well as"hip infection+prosthesis retention".A total of 11 studies reporting on 292 cases could be identified.Five different treatment modalities have been described with varying success rates(debridement-21%infection eradication rate;debridement+lavage-75%infection eradication rate;debridement,lavage,with change of modular prosthesis components-70.4%infection eradication rate;debridement,lavage,change of modular prosthesis components+vacuum-assisted closure-92.8%infection eradication rate;acetabular cup removal+spacer head onto retained stem-89.6%infection eradication rate).With regard to the postoperative antibiotic therapy,no general consensus could be drawn from the available data.Debridement,antibiotic therapy,irrigation,and prosthesis retention is an acceptable solution in the management of early and acute hematogenous periprosthetic hip joint infections.The current literature does not allow for generalization of conclusions with regard to thebest treatment modality.A large,multi-center study is required for identification of the optimal treatment of these infections. 展开更多
关键词 HIP joint infection prosthesis RETENTION DEBRIDEMENT HIP revision Antibiotic therapy Irrigation
下载PDF
The Knee Joint Design and Control of Above-knee Intelligent Bionic Leg Based on Magneto-rheological Damper 被引量:7
14
作者 Hua-Long Xie Ze-Zhong Liang +1 位作者 Fei Li Li-Xin Guo 《International Journal of Automation and computing》 EI 2010年第3期277-282,共6页
The above-knee intelligent bionic leg is very helpful to amputees in the area of rehabilitation medicine. This paper first introduces the functional demand of the above-knee prosthesis design. Then, the advantages of ... The above-knee intelligent bionic leg is very helpful to amputees in the area of rehabilitation medicine. This paper first introduces the functional demand of the above-knee prosthesis design. Then, the advantages of the four-bar link mechanism and the magneto-rheological (MR) damper are analyzed in detail. The fixed position of the MR damper is optimized and a virtual prototype of knee joint is given. In the end, the system model of kinematics, dynamics, and controller are given and a control experiment is performed. The control experiment indicates that the intelligent bionic leg with multi-axis knee is able to realize gait tracking of the amputee's healthy leg based on semi-active control of the MR damper. 展开更多
关键词 Knee joint above-knee intelligent bionic leg magneto-rheological damper.
下载PDF
Factors influencing utilization and satisfaction with external breast prosthesis in patients with mastectomy:A systematic review 被引量:6
15
作者 Ya-nan Liang Bo Xu 《International Journal of Nursing Sciences》 2015年第2期218-224,共7页
Purpose:The aim of this study is to describe and analyse the factors which influence utilization of EBPs among breast cancer patients worldwide and particularly in China.Methods:Literature searches were conducted in W... Purpose:The aim of this study is to describe and analyse the factors which influence utilization of EBPs among breast cancer patients worldwide and particularly in China.Methods:Literature searches were conducted in Wanfang,CNKI,and PubMed databses in order to identify relevant articles published in both Chinese and English up to October 2014.The phrase“external breast prosthesis”in Chinese was used to search titles,abstracts,and key words to find articles in Wanfang and CNKI electronic databases.Synonyms and related terms for external breast prosthesis were combined and used for searches performed in PubMed.Additional references were subsequently extracted from the bibliographies of all included articles and reviews.Qualitative analysis was applied in this study rather than meta-analysis.Results:The number of relevant studies published in other countries is five times greater than the literature published in China,with most articles written by Australian scientists.Based on the existing references,reconstruction,comfort,appearance,cost,mental status,and supportive information were the main factors influencing choice of treatment options by patients.Conclusion:Six main factors influencing EBP use worldwide were identified.Although the number of breast cancer cases per year is increasing at a much higher rate in China relative to the average number globally,relevant studies on Chinese patients are lacking.Thus,further studies should be undertaken in China in order to develop effective service modalities in order to improve quality of life of patients. 展开更多
关键词 External prosthesis UTILIZATION SATISFACTION Systematic review
下载PDF
Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis 被引量:1
16
作者 Godwin Clovis Da Costa Meena Ajay Aras +1 位作者 Paul Chalakkal Michelle Clovis Da Costa 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期148-156,共9页
The article highlights a new method for the fabrication of an ocular prosthesis by the incorporation of a ceramic scleral veneer. The steps of fabrication include impression making, wax try-in, performing a “cut-back... The article highlights a new method for the fabrication of an ocular prosthesis by the incorporation of a ceramic scleral veneer. The steps of fabrication include impression making, wax try-in, performing a “cut-back” on a selected stock eye, insertion of the IPS e-max press scleral veneer, finishing and insertion. It also includes a detailed review on non-integrated ocular prostheses. 展开更多
关键词 IPS e-max press ceramic eye prosthesis ocular prosthesis
下载PDF
Penile prosthesis implantation in a transsexual neophallus 被引量:1
17
作者 Hui-Meng TAN Subang Jaya Medical Centre, Subang Jaya 47500, Malaysia 《Asian Journal of Andrology》 SCIE CAS CSCD 2000年第4期304-306,共3页
Reconstruction surgery for a female to male transsexual usually involves mastectomy, hysterectomy and creating anaesthetically appealing neophallus. We have successfiflly inserted an inflatable prosthesis using the AM... Reconstruction surgery for a female to male transsexual usually involves mastectomy, hysterectomy and creating anaesthetically appealing neophallus. We have successfiflly inserted an inflatable prosthesis using the AMS CX prosthesisin a 45 year old transsexual, who had a large bulky neophallus constructed from the anterior abdominal subcutaneousfat, about 9 years ago. The single cylinder CX prosthesis was well anchored to the symphysis pubis using a dacronwindsock tubing, the activation pump was placed in the dependent pouch of the right labium and the reservior in theusual perivesical space. The patient subsequently had debulking procedure using liposuction to create a more aestheticand functional phallus. To date, the inflatable neophallus prosthesis is functioning well. (Asian J Androl 2000 Dec;2: 304-306) 展开更多
关键词 TRANSSEXUAL neophallus penile prosthesis dacron graft
下载PDF
Customized reconstructive prosthesis design based on topological optimization to treat severe proximal tibia defect 被引量:5
18
作者 Aobo Zhang Hao Chen +5 位作者 Yang Liu Naichao Wu Bingpeng Chen Xue Zhao Qing Han Jincheng Wang 《Bio-Design and Manufacturing》 SCIE EI CSCD 2021年第1期87-99,共13页
A novel reconstructive prosthesis was designed with topological optimization(TO)and a lattice structure to enhance biomechanical and biological properties in the proximal tibia.The biomechanical performance was valida... A novel reconstructive prosthesis was designed with topological optimization(TO)and a lattice structure to enhance biomechanical and biological properties in the proximal tibia.The biomechanical performance was validated through finite element analysis(FEA)and biomechanical tests.The tibia with inhomogeneous material properties was reconstructed according to computed tomography images,and different components were designed to simulate the operation.Minimum compliance TO subject to a volume fraction constraint combined with a graded lattice structure was utilized to redesign the prosthesis.FEA was performed to evaluate the mechanical performances of the tibia and implants after optimization,including stress,micromotion,and strain energy.The results were analyzed by paired-samples t tests,and p<0.05 was considered significant.Biomechanical testing was used to verify the tibial stresses.Compared to the original group(OG),the TO group(TOG)exhibited lower stress on the stem,and the maximum von Mises stresses were 87.2 and 53.1 MPa,respectively,a 39.1%reduction(p<0.05).Conversely,the stress and strain energy on the tibia increased in the TOG.The maximum von Mises stress values were 16.4 MPa in the OG and 22.9 MPa in the TOG with a 39.6%increase(p<0.05),and the maximum SED value was 0.026 MPa in the OG and 0.042 MPa in the TOG,corresponding to an increase of 61.5%(p<0.05).The maximum micromotions in the distal end of the stem were 135μm in the OG and 68μm in the TOG,almost a 50%reduction.The stress curves of the biomechanical test coincided well with the FEA results.The TO approach can effectively reduce the whole weight of the prosthesis and improve the biomechanical environment of the tibia.It could also pave the way for next-generation applications in orthopedics surgery. 展开更多
关键词 Customized reconstructive prosthesis Topological optimization Finite element analysis Graded lattice Severe bone defect Proximal tibia
下载PDF
Voluntary Thigh Muscle Strength with Resection Stump-Dependent Blood Flow and Vasodilation in an Amputated Lower Leg with Total Surface Bearing Prosthesis during Dynamic Knee Extensor: A Case Trial 被引量:1
19
作者 Takuya Osada Masahiro Ishiyama Ryuichi Ueno 《Open Journal of Therapy and Rehabilitation》 2019年第4期151-169,共19页
Background: The magnitude of the hyperemic response due to repeated thigh stump exercise on incremental contraction intensity might be useful information in localized exercise tolerance for devising cardiovascular phy... Background: The magnitude of the hyperemic response due to repeated thigh stump exercise on incremental contraction intensity might be useful information in localized exercise tolerance for devising cardiovascular physical therapy for amputees. The effect of exercise on amputated leg blood flow (LBF) may potentially be altered due to voluntary muscle contractions after loss of the lower leg compared with the healthy leg. Case Presentation: A 57-year-old male patient with Burger disease attempted 3 min unilateral repeat/dynamic knee extensor exercise at a target muscle contraction frequency (1 s thigh muscle contraction and 1 s relaxation, 90 repetitions) with each leg <right transtibial amputated leg (AL) using a total surface-bearing prosthesis (TSB) and left non-AL> at six different contraction intensities (rubber resistance belt). Simultaneous measurement of blood velocity/flow (Doppler ultrasound) in the femoral artery, blood pressure, leg vascular conductance (LVC), and peak muscle strength (PMS) were performed during the 3 min exercise period. The maximum voluntary contraction by one-legged isometric knee muscle contraction was 14.7 kg in non-AL and 7.9 kg in the AL with prosthesis. The relative PMS was defined as “PMS/maximum voluntary contraction × 100 (%)”. Pre-exercise LBF was lower in the AL (200 ± 25 ml/min) than the non-AL (275 ± 74 ml/min). Both the non-AL and AL showed good positive linear relationships between absolute-/relative-PMS and LBF or LVC during 30 s at steady-state before the end of the exercise period. Furthermore, there was also similarity seen in the increase rate in LBF and/or LVC for the incremental relative PMS compared with the absolute PMS. Conclusion: In this case, the muscle strength depended on blood flow increase/vasodilation was seen in this “AL” using a TSB prosthesis for repeated dynamic knee extensor exercise. The present amputee’s limb muscle strengthening with the resection stump closely related to the degree of hyperemia in the amputated limb. 展开更多
关键词 Exercising Leg Blood Flow VASODILATION TRANSTIBIAL Amputation TOTAL SURFACE BEARING prosthesis Doppler Ultrasound
下载PDF
Population-Based and Personalized Design of Total Knee Replacement Prosthesis for Additive Manufacturing Based on Chinese Anthropometric Data 被引量:1
20
作者 C.S.Chui K.S.Leung +10 位作者 J.Qin D.Shi P.Augat R.M.Y.Wong S.K.H.Chow X.Y.Huang C.Y.Chen Y.X.Lai P.S.H.Yung L.Qin W.H.Cheung 《Engineering》 SCIE EI 2021年第3期386-394,共9页
At present,most total knee replacement(TKR)prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A ... At present,most total knee replacement(TKR)prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A number of reports have indicated that Chinese TKR patients do not match with available prostheses.In this study,computed tomography(CT)images of 52 knees of Chinese men and women were used for anthropometric measurements.Index and geometric measurements were definedand used for correlation analysis.Key parameters from the measurement results were identified.Detailed geometries of knees were measured as coordinates.A deformable three-dimensional(3D)knee modelbased on anatomical coordinates correlating with the identified key parameters was generated.A pros-thesis was then designed according to the analyzed results.Surface matching analysis,bone resectionanalysis,and cadaveric trials were conducted and compared with commercial products to validate theproposed design.The femoral component designed by this study resulted in the highest accuracy(rootmean square point-to-surface(RMS PS),(1.08±0.20)mm)and lowest amount of resected bone volume(27412mm^(3))in comparison with two commercial knee prostheses.This study suggests a new approachfor population-based patient-specific femoral prosthesis design With a single,easilty acquired dimen-sion-namely,epicondyle width(ECW)-as input,a patient-specific femoral prosthesis can be designed according to the analyzed measured data and manufactured by additive manufacturing(AM)methods.Meanwhile,the reconstructed femoral condylar surface was compared with the femoral condylar surfacein the original CT scanning data The average RMS PS distance of the reconstructed femoral condylar surface among all data was(1.10±0.18)mm,which is comparable to other statistical shape modeling methods using multiple radiographs as input data.There is a need to develop an anthropometric-based knee prosthesis for the Chinese population.Based on the anthropometry of the Chinese population,our new design fits Chinese patients better and reserves more bone volume compared with current commercial prostheses,which is an essential step toward AM for personalized knee prostheses. 展开更多
关键词 Additive manufacturing Population-based design Total knee replacement Knee prosthesis Anthropometric measurement
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部