期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Absolute Wall Thickness Measurement of Conducting Plates Using Pulsed Eddy Currents
1
作者 Victor-O. de Haan Riccardo Scottini 《Journal of Electromagnetic Analysis and Applications》 2024年第3期25-41,共17页
The method using pulsed eddy currents to determine the thickness of a conduction plate is extended to enable the simultaneous measurement of the plate thickness and material properties. For optimal performance, a prob... The method using pulsed eddy currents to determine the thickness of a conduction plate is extended to enable the simultaneous measurement of the plate thickness and material properties. For optimal performance, a probe must be designed depending on the thickness range that should be accessible. The need for a calibration of the material properties of a conducting plate to enable the measurement of its thickness has been removed. All that is needed is a probe with known dimensions and suitable hardware to create a current pulse and measure a transient magnetic induction. 展开更多
关键词 Pulsed Eddy Currents Wall Thickness absolute and Relative measurements
下载PDF
A diode laser spectrometer at 634 nm and absolute frequency measurements using optical frequency comb 被引量:1
2
作者 伊林 袁杰 +5 位作者 齐向晖 陈文兰 周大伟 周通 周小计 陈徐宗 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第4期1409-1412,共4页
This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the... This paper reports that two identical external-cavity-diode-laser (ECDL) based spectrometers are constructed at 634nm referencing on the hyperfine B-X transition R(80)8-4 of 127I2. The lasers are stabilized on the Doppler-free absorption signals using the third-harmonic detection technique. The instability of the stabilized laser is measured to be 2.8 × 10^-12 (after 1000 s) by counting the beat note between the two lasers. The absolute optical frequency of the transition is, for the first time, determined to be 472851936189.5 kHz by using an optical frequency comb referenced on the microwave caesium atomic clock. The uncertainty of the measurement is less than 4.9 kHz. 展开更多
关键词 frequency standard optical frequency comb absolute frequency measurement atomicclock
下载PDF
Joint processing and analysis of seismic gravity measurements in Capital Circle area
3
作者 贾民育 马丽 +3 位作者 刘少明 张晶 孙少安 王武星 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2006年第4期438-447,共10页
In Capital Circle area, there are three groups of repeated gravity measurements observed by different institutes using different instruments or methods. The simultaneous adjustment of absolute and relative measurement... In Capital Circle area, there are three groups of repeated gravity measurements observed by different institutes using different instruments or methods. The simultaneous adjustment of absolute and relative measurements and the elimination of systematic error among the relative measurements have been carded out in this paper. Thus an unified temporal gravity change system with absolute reference has been established. On the basis of this, the crustal subsidence effect on gravity, which belongs to non-tectonic factor, is analyzed and the station displacement corrections are carried out, so that the long-wave disturbance is eliminated. So far our following aims are realized: the advantages of the absolute and relative measurement methods are complementary to each other; the contradiction and environment disturbance are eliminated; the amounts of information are enlarged; the sampling interval of time domain is compressed. In a word, the ability of identifying the tectonic activity process is enhanced. The results show that: there are systematic errors between the two groups of relative measurements and within the data of 10 campaigns ; the uneven local crustal subsidence in the southeast of the study area results in a linear rise of gravity value at 10 stations; they can be corrected by the regression analysis. The maps of revised temporal gravity change can obviously and integrally reflect the Ms=5.0 earthquake in Guye on October 6, 1995. 展开更多
关键词 Capital Circle area temporal gravity change relative measurement absolute measurement unified system
下载PDF
Absolutely Direct Frequency Measurement of Two-Photon Transition Using Multi-Peak Fitting Approach
4
作者 戴少阳 李坤乾 +5 位作者 翟跃阳 夏巍 王青 熊炜 齐向晖 陈徐宗 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期32-35,共4页
The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring tr... The optical frequency comb has been widely used in precision measurement. In this study, a multi-peak fitting approach is first proposed to fit the two-photon transition spectrum which overlaps with the neighboring transition in Rb-87. The multi-peak fitting approach is used to eliminate the frequency shift affected by the neighboring transition. With locking the carrier envelope offset frequency at 1/4 repetition frequency, the transition frequency is measured to be 770569132739.9 +/- 5.8 kHz, which agrees well with the previous result recommended by Comite International des Poids et Mesures. 展开更多
关键词 In absolutely Direct Frequency Measurement of Two-Photon Transition Using Multi-Peak Fitting Approach Rb
下载PDF
Erratum to “Absolute Measurement of Cross Sections of ^(27)Al(n,α)^(24)Na and ^(56)Fe(n,p)^(56)Mn Reactions at E_n=14.6 MeV”
5
作者 Bao Zongyu Rong Chaofan Yang Xiaoyun (China Institute of Atomic Energy,P.O.Box 275-20,Beijing 102413) 《Chinese journal of nuclear physics》 1994年第4期358-358,共1页
The publisher regrets that some misprints appeared in the formula for the correction factork on page 343.It is reprinted correctly as the following:k=n(1-e<sup>-λ(t<sub>1</sub>-t<sub>0</su... The publisher regrets that some misprints appeared in the formula for the correction factork on page 343.It is reprinted correctly as the following:k=n(1-e<sup>-λ(t<sub>1</sub>-t<sub>0</sub>)/n</sup>)/e<sup>λ(t<sub>1</sub>-t<sub>0</sub>)</sup>-1·(sum from i=1 to n N<sub>ai</sub>e<sup>iλ(l<sub>1</sub>-l<sub>0</sub>)/n</sup>)/sum from i=1 to n N<sub>ai</sub> 展开更多
关键词 Na and Fe absolute Measurement of Cross Sections of Mn Reactions at E_n Erratum to n p Al
下载PDF
Coseismic gravity and displacement changes of Japan Tohoku earthquake(Mw 9.0) 被引量:2
6
作者 Xinlin Zhang Shuhei Okubo +1 位作者 Yoshiyuki Tanaka Hui Li 《Geodesy and Geodynamics》 2016年第2期95-100,共6页
The greatest earthquake in the modern history of Japan and probably the fourth greatest in the last 100 years in the world occurred on March 11, 2011 off the Pacific coast of Tohoku.Large tsunami and ground motions ca... The greatest earthquake in the modern history of Japan and probably the fourth greatest in the last 100 years in the world occurred on March 11, 2011 off the Pacific coast of Tohoku.Large tsunami and ground motions caused severe damage in wide areas, particularly many towns along the Pacific coast. So far, gravity change caused by such a great earthquake has been reported for the 1964 Alaska and the 2010 Maule events. However, the spatial-temporal resolution of the gravity data for these cases is insufficient to depict a co-seismic gravity field variation in a spatial scale of a plate subduction zone. Here, we report an unequivocal co-seismic gravity change over the Japanese Island, obtained from a hybrid gravity observation(combined absolute and relative gravity measurements). The time interval of the observation before and after the earthquake is within 1 year at almost all the observed sites, including 13 absolute and 16 relative measurement sites, which deduced tectonic and environmental contributions to the gravity change. The observed gravity agrees well with the result calculated by a dislocation theory based on a self-gravitating and layered spherical earth model. In this computation, a co-seismic slip distribution is determined by an inversion of Global Positioning System(GPS) data. Of particular interest is that the observed gravity change in some area is negative where a remarkable subsidence is observed by GPS, which can not be explained by simple vertical movement of the crust. This indicated that the mass redistribution in the underground affects the gravity change. This result supports the result that Gravity Recovery and Climate Experiment(GRACE) satellites detected a crustal dilatation due to the 2004 Sumatra earthquake by the terrestrial observation with a higher spatial and temporal resolution. 展开更多
关键词 Tohoku earthquake(Mw 9.0) Co-seismic gravity change Co-seismic displacement change Coseismic geoid change Dislocation theory Global Positioning System absolute gravity measurement Relative gravity measurement
下载PDF
REFINABLE DISTRIBUTIONS SUPPORTED ON SELF-AFFINE TILES
7
作者 Dai XinrongDept. of Math.,Zhejiang Univ. of Technology, Hangzhou 310032. 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2002年第1期69-74,共6页
In this paper,some conditions which assure the compactly supported refinable distributions supported on a self-affine tile to be Lebesgue-Stieltjes measures or absolutely continuous measures with respect to Lebesgue-S... In this paper,some conditions which assure the compactly supported refinable distributions supported on a self-affine tile to be Lebesgue-Stieltjes measures or absolutely continuous measures with respect to Lebesgue-Stieltjes measures are given. 展开更多
关键词 self-affine tile refinable distribution Lebesgue-Stieltjes measure absolutely continuous measure.
下载PDF
Design and Parameter Optimization of Zero Position Code Considering Diffraction Based on Deep Learning Generative Adversarial Networks
8
作者 Shengtong Wang Linbin Luo Xinghui Li 《Nanomanufacturing and Metrology》 EI 2024年第1期15-27,共13页
Absolute measurement has consistently been the primary focus in the development of precision linear and angular displace-ment measurements.The scheme design of binary zero position codes is an important factor for abs... Absolute measurement has consistently been the primary focus in the development of precision linear and angular displace-ment measurements.The scheme design of binary zero position codes is an important factor for absolute measurement.Designing and optimizing high-bit zero position codes with over 100 bits face considerable challenges.Simultaneously,the working parameters of zero position codes[unit code width(b),distance(d),and yaw angle(α)]remarkably affect their post-installation performance,particularly in absolute positioning and limit code application in multi-degree-of-freedom measurement schemes.This study addresses these challenges by proposing a design method for zero position codes that considers diffraction based on generative adversarial networks and aims to explore a design with increased efficiency and accuracy as well as optimization for high-bit zero position codes.Additionally,the tolerance range of zero positioning per-formance for each working parameter is examined.By leveraging the adversarial network structure,this study generates the optimization of a 150-bit code and processes the tests of the zero position code by using simulation results.The following working parameter ranges for code design are recommended on the basis of theoretical and experimental results:b greater than 10μm,d andαwithin 1000μm and 3490μrad,and avoidance of intervals with sharp changes in the full width at half maximum.The proposed code design and parameter optimization lay a solid foundation for research and engineering appli-cations in absolute measurement field and have considerable potential for generalization and wide applicability. 展开更多
关键词 absolute measurement Zero position code Deep learning Generative adversarial networks Tolerance range Parameter optimization
原文传递
Absolute small-angle measurement based on optical feedback interferometry 被引量:13
9
作者 钟金钢 张冼华 琚志祥 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第11期830-832,共3页
We present a simple but effective method for small-angle measurement based on optical feedback interferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe ampli... We present a simple but effective method for small-angle measurement based on optical feedback interferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe amplitude point, so this method can also achieve absolute angle measurement. In order to verify the method, we construct an angle measurement system. The Fourier-transform method is used to analysis the interference signal. Rotation angles are experimentally measured with a resolution of 10^-6 rad and a measurement range of approximately from -0.0007 to +0.0007 rad. 展开更多
关键词 absolute small-angle measurement based on optical feedback interferometry
原文传递
Absolute surface form measurement of flat optics based on oblique incidence method 被引量:1
10
作者 徐隆波 刘世杰 +2 位作者 朱日宏 周游 陈洁 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第10期30-33,共4页
In this Letter, a test method based on oblique incidence is practically implemented in the interferometric measurement process. Three sets of wavefront data are achieved through cavity interference measurement with a ... In this Letter, a test method based on oblique incidence is practically implemented in the interferometric measurement process. Three sets of wavefront data are achieved through cavity interference measurement with a Fizeau interferometer and one oblique incidence measurement. An iterative algorithm is applied to retrieve the absolute surface shape of the test flat. By adding two sets of measurements, the absolute surface error of the interferometer's reference flat can be obtained. The new method can not only calibrate the reference flat error of interferometer, but also provide the absolute measurement method for high precision optical components applied in high power laser systems. 展开更多
关键词 absolute surface form measurement of flat optics based on oblique incidence method
原文传递
Absolute measurement of radiant power for synchrotron radiation monochromatized X-rays
11
作者 Fan Li Yi-Dong Zhao +6 位作者 Pei-Wei Wang Lei Zheng Si-Ming Guo Ji Wang Kun Tang Xiao-Juan Zhao Jian-Min Li 《Radiation Detection Technology and Methods》 CSCD 2020年第1期97-105,共9页
Purpose Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics,spectroscopy,and X-ray diagnostics.This paper presents a dependable method of absolute measurement o... Purpose Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics,spectroscopy,and X-ray diagnostics.This paper presents a dependable method of absolute measurement of radiant power for synchrotron radiation monochromatized X-rays.Methods A free-air ionization chamber was examined closely and employed as the detector in the present work.Its measuring principle was discussed,and the correction factors were determined.Absolute measurement of radiant power for synchro-tron radiation monochromatized X-rays in the region of 6-20 keV was performed using the free-air ionization chamber at Beijing Synchrotron Radiation Facility.As a verification and an important application,photodiodes were calibrated against the free-air ionization chamber.Results Relative standard uncertainties of absolute measurement using free-air ionization chamber are about 1%.Calibration of photodiodes within the photon energy range from 6 to 20 keV has relative standard uncertainties below 1.5%.Conclusion The free-air ionization chamber is qualified to be used in many disciplines to support the measurement of opti-cal radiation. 展开更多
关键词 absolute measurement Radiant power Free-air ionization chamber Synchrotron radiation X-ray
原文传递
Optical Frequency Comb Frequency-division Multiplexing Dispersive Interference Multichannel Distance Measurement 被引量:1
12
作者 Xu Liang Tengfei Wu +2 位作者 Jiarui Lin Linghui Yang Jigui Zhu 《Nanomanufacturing and Metrology》 EI 2023年第1期61-68,共8页
An optical frequency comb(OFC)frequency-division multiplexing dispersive interference multichannel distance measurement method is proposed.Based on the OFC dispersive interference,the wide OFC spectrum is divided into... An optical frequency comb(OFC)frequency-division multiplexing dispersive interference multichannel distance measurement method is proposed.Based on the OFC dispersive interference,the wide OFC spectrum is divided into multiple channels using a wavelength-division multiplexer.Under the existing light source and spectrometer,a single interference system can realize six channels of the high-precision parallel absolute distance measurement.The influence of the spectrum width and shape on the performance of the distance measurement channel is analyzed.The ranging accuracy of six channels is higher than±4μm under the optimization of a nonuniform discrete Fourier transform and Hanning window. 展开更多
关键词 Frequency-division multiplexing Dispersive interference absolute distance measurement Fourier transform
原文传递